Prediction of implant stability in total hip arthroplasty / Muhammad Syahmi Yusof

Total Hip Arthroplasty (THA) is one of the most successful and common procedures in orthopaedic surgery to treat the advanced stage of osteoarthritis. It is well-known that THA is a successful orthopaedic procedure by replacing the damage bone to restore the function anatomy and improved quality of...

Full description

Saved in:
Bibliographic Details
Main Author: Yusof, Muhammad Syahmi
Format: Thesis
Language:English
Published: 2021
Subjects:
Online Access:https://ir.uitm.edu.my/id/eprint/46695/1/46695.pdf
https://ir.uitm.edu.my/id/eprint/46695/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uitm.ir.46695
record_format eprints
spelling my.uitm.ir.466952022-04-28T04:24:21Z https://ir.uitm.edu.my/id/eprint/46695/ Prediction of implant stability in total hip arthroplasty / Muhammad Syahmi Yusof Yusof, Muhammad Syahmi RD Surgery Operative surgery. Technique of surgical operations Total Hip Arthroplasty (THA) is one of the most successful and common procedures in orthopaedic surgery to treat the advanced stage of osteoarthritis. It is well-known that THA is a successful orthopaedic procedure by replacing the damage bone to restore the function anatomy and improved quality of life which promoting long term survivorship. However, THA has its own risk and complication that lead to poor outcomes due to implant stability during surgery. Thus, the Finite Element Analysis (FEA) was demonstrated to predict the implant stability by computational analysis of biomechanical behaviour. A 3D model of femoral bone was developed from Computed Tomography (CT) images of 54 years old patient. The cementless finite element model of THA was constructed at varus and sagittal from -3° to 3° to present the implant stability. The material properties of femur and prosthesis stem were assigned as cortical (E=17 GPa, v=0.33) and Titanium alloy, Ti-6AL-4V (E=110 GPa, v=0.3). The type of prosthesis stem design is an Anatomic Modularly Locking (AML) which specific for cementless hip arthroplasty. The static analysis was performed using finite element model of cementless THA with various implant position at varus and sagittal from -3° to 3° under loading condition of stair climbing. The results of maximum principle stress of cortical bone at varus and sagittal were compare with normal implant position. The maximum stress of proximal region at varus and sagittal were 102.20 MPa and 80.99 MPa whereas distal region were 82.76 MPa and 65.35 MPa. The effect of implant stability at varus is more significant compare to sagittal. The state of stresses based on implant stability at proximal and distal region where the cortical bone is bonded with implant. In analysis of implant stability, the stresses of varus and sagittal increases up to 75% and 39% respectively with respect to normal condition which are 58.26 MPa and 47.24 MPa. The average stresses of varus and sagittal at proximal and distal tip of prosthesis were 70% to 80% and 59% - 66%. The Von Mises stresses of prosthesis stem under stair climbing involved critical position at varus and sagittal (3° and -3°) were analysed. All the stresss state of cementless prosthesis stem were in range 310 MPa - 360 MPa. Therefore, all the results of stress were significantly lower than yield stresses of cortical bone and Titanium alloy which indicates no risk of fracture and failure. 2021-04 Thesis NonPeerReviewed text en https://ir.uitm.edu.my/id/eprint/46695/1/46695.pdf (2021) Prediction of implant stability in total hip arthroplasty / Muhammad Syahmi Yusof. Masters thesis, thesis, Universiti Teknologi MARA.
institution Universiti Teknologi Mara
building Tun Abdul Razak Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Mara
content_source UiTM Institutional Repository
url_provider http://ir.uitm.edu.my/
language English
topic RD Surgery
Operative surgery. Technique of surgical operations
spellingShingle RD Surgery
Operative surgery. Technique of surgical operations
Yusof, Muhammad Syahmi
Prediction of implant stability in total hip arthroplasty / Muhammad Syahmi Yusof
description Total Hip Arthroplasty (THA) is one of the most successful and common procedures in orthopaedic surgery to treat the advanced stage of osteoarthritis. It is well-known that THA is a successful orthopaedic procedure by replacing the damage bone to restore the function anatomy and improved quality of life which promoting long term survivorship. However, THA has its own risk and complication that lead to poor outcomes due to implant stability during surgery. Thus, the Finite Element Analysis (FEA) was demonstrated to predict the implant stability by computational analysis of biomechanical behaviour. A 3D model of femoral bone was developed from Computed Tomography (CT) images of 54 years old patient. The cementless finite element model of THA was constructed at varus and sagittal from -3° to 3° to present the implant stability. The material properties of femur and prosthesis stem were assigned as cortical (E=17 GPa, v=0.33) and Titanium alloy, Ti-6AL-4V (E=110 GPa, v=0.3). The type of prosthesis stem design is an Anatomic Modularly Locking (AML) which specific for cementless hip arthroplasty. The static analysis was performed using finite element model of cementless THA with various implant position at varus and sagittal from -3° to 3° under loading condition of stair climbing. The results of maximum principle stress of cortical bone at varus and sagittal were compare with normal implant position. The maximum stress of proximal region at varus and sagittal were 102.20 MPa and 80.99 MPa whereas distal region were 82.76 MPa and 65.35 MPa. The effect of implant stability at varus is more significant compare to sagittal. The state of stresses based on implant stability at proximal and distal region where the cortical bone is bonded with implant. In analysis of implant stability, the stresses of varus and sagittal increases up to 75% and 39% respectively with respect to normal condition which are 58.26 MPa and 47.24 MPa. The average stresses of varus and sagittal at proximal and distal tip of prosthesis were 70% to 80% and 59% - 66%. The Von Mises stresses of prosthesis stem under stair climbing involved critical position at varus and sagittal (3° and -3°) were analysed. All the stresss state of cementless prosthesis stem were in range 310 MPa - 360 MPa. Therefore, all the results of stress were significantly lower than yield stresses of cortical bone and Titanium alloy which indicates no risk of fracture and failure.
format Thesis
author Yusof, Muhammad Syahmi
author_facet Yusof, Muhammad Syahmi
author_sort Yusof, Muhammad Syahmi
title Prediction of implant stability in total hip arthroplasty / Muhammad Syahmi Yusof
title_short Prediction of implant stability in total hip arthroplasty / Muhammad Syahmi Yusof
title_full Prediction of implant stability in total hip arthroplasty / Muhammad Syahmi Yusof
title_fullStr Prediction of implant stability in total hip arthroplasty / Muhammad Syahmi Yusof
title_full_unstemmed Prediction of implant stability in total hip arthroplasty / Muhammad Syahmi Yusof
title_sort prediction of implant stability in total hip arthroplasty / muhammad syahmi yusof
publishDate 2021
url https://ir.uitm.edu.my/id/eprint/46695/1/46695.pdf
https://ir.uitm.edu.my/id/eprint/46695/
_version_ 1732948320710557696
score 13.211869