Evaluation of internal properties of bamboo particleboard using computerized radiography testing / Abu Bakar Daud
The aim of this research is to evaluate internal properties of bamboo particle board such as density and thickness weather it is effect or not the exposure time of x-ray to penetrate the samples by constructing exposure chart. The particle board was made based on the three density level which is 700...
Saved in:
Main Author: | |
---|---|
Format: | Student Project |
Language: | English |
Published: |
2012
|
Subjects: | |
Online Access: | http://ir.uitm.edu.my/id/eprint/43801/1/43801.pdf http://ir.uitm.edu.my/id/eprint/43801/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.uitm.ir.43801 |
---|---|
record_format |
eprints |
spelling |
my.uitm.ir.438012021-03-19T08:01:49Z http://ir.uitm.edu.my/id/eprint/43801/ Evaluation of internal properties of bamboo particleboard using computerized radiography testing / Abu Bakar Daud Daud, Abu Bakar Descriptive and experimental mechanics Engineering mathematics. Engineering analysis Materials of engineering and construction The aim of this research is to evaluate internal properties of bamboo particle board such as density and thickness weather it is effect or not the exposure time of x-ray to penetrate the samples by constructing exposure chart. The particle board was made based on the three density level which is 700kg/m , 800kg/m and 900kg/m . Each density consist of six different thickness which is 10, 20, 30, 40, 50, 60 mm. Then the sample was exposed to the x-ray source using both conventional radiography as a test shoot and CRT for construct the exposure chart by setting the source-to-film (SFD) and current(mA) to be constant. Then, by varied the penetration power of x-ray tube and thickness of the samples, the radio graphic images produced was then evaluated using densitometer for conventional and D-Tech Software for CRT in order to determine the film density. When the film density is in the range of 1.9 to 2.0, then exposure chart of each density was constructed. This exposure chart show the exposure time is directly proportional to the thickness of the sample and inversely proportional to the penetration power. From the exposure chart the best penetration power in this study was found to be 80 kV. 2012-01 Student Project NonPeerReviewed text en http://ir.uitm.edu.my/id/eprint/43801/1/43801.pdf Daud, Abu Bakar (2012) Evaluation of internal properties of bamboo particleboard using computerized radiography testing / Abu Bakar Daud. [Student Project] (Unpublished) |
institution |
Universiti Teknologi Mara |
building |
Tun Abdul Razak Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Mara |
content_source |
UiTM Institutional Repository |
url_provider |
http://ir.uitm.edu.my/ |
language |
English |
topic |
Descriptive and experimental mechanics Engineering mathematics. Engineering analysis Materials of engineering and construction |
spellingShingle |
Descriptive and experimental mechanics Engineering mathematics. Engineering analysis Materials of engineering and construction Daud, Abu Bakar Evaluation of internal properties of bamboo particleboard using computerized radiography testing / Abu Bakar Daud |
description |
The aim of this research is to evaluate internal properties of bamboo particle board such as density and thickness weather it is effect or not the exposure time of x-ray to penetrate the samples by constructing exposure chart. The particle board was made based on the three density level which is 700kg/m , 800kg/m and 900kg/m . Each density consist of six different thickness which is 10, 20, 30, 40, 50, 60 mm. Then the sample was exposed to the x-ray source using both conventional radiography as a test shoot and CRT for construct the exposure chart by setting the source-to-film (SFD) and current(mA) to be constant. Then, by varied the penetration power of x-ray tube and thickness of the samples, the radio graphic images produced was then evaluated using densitometer for conventional and D-Tech Software for CRT in order to determine the film density. When the film density is in the range of 1.9 to 2.0, then exposure chart of each density was constructed. This exposure chart show the exposure time is directly proportional to the thickness of the sample and inversely proportional to the penetration power. From the exposure chart the best penetration power in this study was found to be 80 kV. |
format |
Student Project |
author |
Daud, Abu Bakar |
author_facet |
Daud, Abu Bakar |
author_sort |
Daud, Abu Bakar |
title |
Evaluation of internal properties of bamboo particleboard using computerized radiography testing / Abu Bakar Daud |
title_short |
Evaluation of internal properties of bamboo particleboard using computerized radiography testing / Abu Bakar Daud |
title_full |
Evaluation of internal properties of bamboo particleboard using computerized radiography testing / Abu Bakar Daud |
title_fullStr |
Evaluation of internal properties of bamboo particleboard using computerized radiography testing / Abu Bakar Daud |
title_full_unstemmed |
Evaluation of internal properties of bamboo particleboard using computerized radiography testing / Abu Bakar Daud |
title_sort |
evaluation of internal properties of bamboo particleboard using computerized radiography testing / abu bakar daud |
publishDate |
2012 |
url |
http://ir.uitm.edu.my/id/eprint/43801/1/43801.pdf http://ir.uitm.edu.my/id/eprint/43801/ |
_version_ |
1695534712171266048 |
score |
13.211869 |