Evaluation of internal properties of bamboo particleboard using computerized radiography testing / Abu Bakar Daud

The aim of this research is to evaluate internal properties of bamboo particle board such as density and thickness weather it is effect or not the exposure time of x-ray to penetrate the samples by constructing exposure chart. The particle board was made based on the three density level which is 700...

Full description

Saved in:
Bibliographic Details
Main Author: Daud, Abu Bakar
Format: Student Project
Language:English
Published: 2012
Subjects:
Online Access:http://ir.uitm.edu.my/id/eprint/43801/1/43801.pdf
http://ir.uitm.edu.my/id/eprint/43801/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uitm.ir.43801
record_format eprints
spelling my.uitm.ir.438012021-03-19T08:01:49Z http://ir.uitm.edu.my/id/eprint/43801/ Evaluation of internal properties of bamboo particleboard using computerized radiography testing / Abu Bakar Daud Daud, Abu Bakar Descriptive and experimental mechanics Engineering mathematics. Engineering analysis Materials of engineering and construction The aim of this research is to evaluate internal properties of bamboo particle board such as density and thickness weather it is effect or not the exposure time of x-ray to penetrate the samples by constructing exposure chart. The particle board was made based on the three density level which is 700kg/m , 800kg/m and 900kg/m . Each density consist of six different thickness which is 10, 20, 30, 40, 50, 60 mm. Then the sample was exposed to the x-ray source using both conventional radiography as a test shoot and CRT for construct the exposure chart by setting the source-to-film (SFD) and current(mA) to be constant. Then, by varied the penetration power of x-ray tube and thickness of the samples, the radio graphic images produced was then evaluated using densitometer for conventional and D-Tech Software for CRT in order to determine the film density. When the film density is in the range of 1.9 to 2.0, then exposure chart of each density was constructed. This exposure chart show the exposure time is directly proportional to the thickness of the sample and inversely proportional to the penetration power. From the exposure chart the best penetration power in this study was found to be 80 kV. 2012-01 Student Project NonPeerReviewed text en http://ir.uitm.edu.my/id/eprint/43801/1/43801.pdf Daud, Abu Bakar (2012) Evaluation of internal properties of bamboo particleboard using computerized radiography testing / Abu Bakar Daud. [Student Project] (Unpublished)
institution Universiti Teknologi Mara
building Tun Abdul Razak Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Mara
content_source UiTM Institutional Repository
url_provider http://ir.uitm.edu.my/
language English
topic Descriptive and experimental mechanics
Engineering mathematics. Engineering analysis
Materials of engineering and construction
spellingShingle Descriptive and experimental mechanics
Engineering mathematics. Engineering analysis
Materials of engineering and construction
Daud, Abu Bakar
Evaluation of internal properties of bamboo particleboard using computerized radiography testing / Abu Bakar Daud
description The aim of this research is to evaluate internal properties of bamboo particle board such as density and thickness weather it is effect or not the exposure time of x-ray to penetrate the samples by constructing exposure chart. The particle board was made based on the three density level which is 700kg/m , 800kg/m and 900kg/m . Each density consist of six different thickness which is 10, 20, 30, 40, 50, 60 mm. Then the sample was exposed to the x-ray source using both conventional radiography as a test shoot and CRT for construct the exposure chart by setting the source-to-film (SFD) and current(mA) to be constant. Then, by varied the penetration power of x-ray tube and thickness of the samples, the radio graphic images produced was then evaluated using densitometer for conventional and D-Tech Software for CRT in order to determine the film density. When the film density is in the range of 1.9 to 2.0, then exposure chart of each density was constructed. This exposure chart show the exposure time is directly proportional to the thickness of the sample and inversely proportional to the penetration power. From the exposure chart the best penetration power in this study was found to be 80 kV.
format Student Project
author Daud, Abu Bakar
author_facet Daud, Abu Bakar
author_sort Daud, Abu Bakar
title Evaluation of internal properties of bamboo particleboard using computerized radiography testing / Abu Bakar Daud
title_short Evaluation of internal properties of bamboo particleboard using computerized radiography testing / Abu Bakar Daud
title_full Evaluation of internal properties of bamboo particleboard using computerized radiography testing / Abu Bakar Daud
title_fullStr Evaluation of internal properties of bamboo particleboard using computerized radiography testing / Abu Bakar Daud
title_full_unstemmed Evaluation of internal properties of bamboo particleboard using computerized radiography testing / Abu Bakar Daud
title_sort evaluation of internal properties of bamboo particleboard using computerized radiography testing / abu bakar daud
publishDate 2012
url http://ir.uitm.edu.my/id/eprint/43801/1/43801.pdf
http://ir.uitm.edu.my/id/eprint/43801/
_version_ 1695534712171266048
score 13.211869