Measurement of dielectric constant of paint coated aluminium panel through microwave non destructive testing at frequency 18 to 26GHz (K Band) / Bibi Nawsheen Ebrahim Saib
Microwave non-destructive testing of paint and primer in components commonly used in moist and salty environment are very crucial in the investigation of signs of corrosion. In this paper, we present a method for measuring the dielectric properties and loss factor of paint coated aluminium panels us...
Saved in:
Main Author: | |
---|---|
Format: | Article |
Language: | English |
Published: |
2009
|
Online Access: | https://ir.uitm.edu.my/id/eprint/39851/1/39851.pdf https://ir.uitm.edu.my/id/eprint/39851/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.uitm.ir.39851 |
---|---|
record_format |
eprints |
spelling |
my.uitm.ir.398512023-08-29T08:32:25Z https://ir.uitm.edu.my/id/eprint/39851/ Measurement of dielectric constant of paint coated aluminium panel through microwave non destructive testing at frequency 18 to 26GHz (K Band) / Bibi Nawsheen Ebrahim Saib Ebrahim Saib, Bibi Nawsheen Microwave non-destructive testing of paint and primer in components commonly used in moist and salty environment are very crucial in the investigation of signs of corrosion. In this paper, we present a method for measuring the dielectric properties and loss factor of paint coated aluminium panels using the metal-backed method. Complex reflection coefficient (Sn) is measured for Plexiglas container backed by metal plate. Dielectric constant and loss factor were measured for corrode and non-corrode paint coated aluminium panel in the frequency range of 18 to 26GHz (K-Band). The thru, reflect and line (TRL) calibration technique were used to eliminate the effect of undesirable multiple reflections. The dielectric constant for corrode paint coated aluminium panels is 2.9± 0.1 and for non-corrode paint coated aluminium panel is 2.5±0.1, showing that the dielectric constant of corrode samples are higher than non-corrode ones. The loss factor for corrode aluminium panels is ranged from -0.02 to -0.01 and for non-corrode aluminium panels, the loss factor is from -0.083 to -0.008. Loss factor for corrode aluminium panel is higher than that of non-corrode aluminium panel. The differences could be due to errors in the magnitude and phase of Su , surface of the paint coated aluminium panel and the air-gap effect during the assembly of the sample. 2009 Article NonPeerReviewed text en https://ir.uitm.edu.my/id/eprint/39851/1/39851.pdf Measurement of dielectric constant of paint coated aluminium panel through microwave non destructive testing at frequency 18 to 26GHz (K Band) / Bibi Nawsheen Ebrahim Saib. (2009) pp. 1-7. (Unpublished) |
institution |
Universiti Teknologi Mara |
building |
Tun Abdul Razak Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Mara |
content_source |
UiTM Institutional Repository |
url_provider |
http://ir.uitm.edu.my/ |
language |
English |
description |
Microwave non-destructive testing of paint and primer in components commonly used in moist and salty environment are very crucial in the investigation of signs of corrosion. In this paper, we present a method for measuring the dielectric properties and loss factor of paint coated aluminium panels using the metal-backed method. Complex reflection coefficient (Sn) is measured for Plexiglas container backed by metal plate. Dielectric constant and loss factor were measured for corrode and non-corrode paint coated aluminium panel in the frequency range of 18 to 26GHz (K-Band). The thru, reflect and line (TRL) calibration technique were used to eliminate the effect of undesirable multiple reflections. The dielectric constant for corrode paint coated aluminium panels is 2.9± 0.1 and for non-corrode paint coated aluminium panel is 2.5±0.1, showing that the dielectric constant of corrode samples are higher than non-corrode ones. The loss factor for corrode aluminium panels is ranged from -0.02 to -0.01 and for non-corrode aluminium panels, the loss factor is from -0.083 to -0.008. Loss factor for corrode aluminium panel is higher than that of non-corrode aluminium panel. The differences could be due to errors in the magnitude and phase of Su , surface of the paint coated aluminium panel and the air-gap effect during the assembly of the sample. |
format |
Article |
author |
Ebrahim Saib, Bibi Nawsheen |
spellingShingle |
Ebrahim Saib, Bibi Nawsheen Measurement of dielectric constant of paint coated aluminium panel through microwave non destructive testing at frequency 18 to 26GHz (K Band) / Bibi Nawsheen Ebrahim Saib |
author_facet |
Ebrahim Saib, Bibi Nawsheen |
author_sort |
Ebrahim Saib, Bibi Nawsheen |
title |
Measurement of dielectric constant of paint coated aluminium panel through microwave non destructive testing at frequency 18 to 26GHz (K Band) / Bibi Nawsheen Ebrahim Saib |
title_short |
Measurement of dielectric constant of paint coated aluminium panel through microwave non destructive testing at frequency 18 to 26GHz (K Band) / Bibi Nawsheen Ebrahim Saib |
title_full |
Measurement of dielectric constant of paint coated aluminium panel through microwave non destructive testing at frequency 18 to 26GHz (K Band) / Bibi Nawsheen Ebrahim Saib |
title_fullStr |
Measurement of dielectric constant of paint coated aluminium panel through microwave non destructive testing at frequency 18 to 26GHz (K Band) / Bibi Nawsheen Ebrahim Saib |
title_full_unstemmed |
Measurement of dielectric constant of paint coated aluminium panel through microwave non destructive testing at frequency 18 to 26GHz (K Band) / Bibi Nawsheen Ebrahim Saib |
title_sort |
measurement of dielectric constant of paint coated aluminium panel through microwave non destructive testing at frequency 18 to 26ghz (k band) / bibi nawsheen ebrahim saib |
publishDate |
2009 |
url |
https://ir.uitm.edu.my/id/eprint/39851/1/39851.pdf https://ir.uitm.edu.my/id/eprint/39851/ |
_version_ |
1776250533654298624 |
score |
13.211869 |