Determination of phenol in water sample using high performance liquid chromatography / Nazurah Haron
Phenol as in water is harmful to living organism yet have a toxicity effect for a long-term exposure. In this research, the analysis was achieved on a C18 column coupled with UV-vis detector (HPLC-UV) for determination of phenol in environmental water while by using solid phase extraction (SPE) as s...
Saved in:
Main Author: | |
---|---|
Format: | Student Project |
Language: | English |
Published: |
2017
|
Subjects: | |
Online Access: | http://ir.uitm.edu.my/id/eprint/35055/1/35055.pdf http://ir.uitm.edu.my/id/eprint/35055/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.uitm.ir.35055 |
---|---|
record_format |
eprints |
spelling |
my.uitm.ir.350552020-10-12T04:18:51Z http://ir.uitm.edu.my/id/eprint/35055/ Determination of phenol in water sample using high performance liquid chromatography / Nazurah Haron Haron, Nazurah Laboratories. General works Extraction (Chemistry) Phenol as in water is harmful to living organism yet have a toxicity effect for a long-term exposure. In this research, the analysis was achieved on a C18 column coupled with UV-vis detector (HPLC-UV) for determination of phenol in environmental water while by using solid phase extraction (SPE) as sample preparation technique. The optimized variable involved in SPE and HPLC were as follow: 3 mL was used for load sample volume in SPE, 45 ± 3 drops min-1 was used for sample drop-rate in SPE and 0.35 mL min-1 as flow-rate on eluent in HPLC. The analytical method was validated based on the following parameter: precision, linear range, limit of detection (LOD), limit of quantitation (LOQ) and bias/recovery. A good linear correlation coefficient with R2 = 0.9996 was observed over the range of 0.55 - 30.0 µg mL-1. Both repeatability and reproducibility (RSD, %) were 0.215 and 1.490, respectively. The limit of detection was calculated to be 0.212 µg mL-1, while the limit of quantitation value of the validated method was measured to be 0.642 µg mL-1. Good recoveries were between 81 - 120%. The proposed method was found to be suitable and precise for the determination of phenol in environmental water by using HPLC. 2017 Student Project NonPeerReviewed text en http://ir.uitm.edu.my/id/eprint/35055/1/35055.pdf Haron, Nazurah (2017) Determination of phenol in water sample using high performance liquid chromatography / Nazurah Haron. [Student Project] (Unpublished) |
institution |
Universiti Teknologi Mara |
building |
Tun Abdul Razak Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Mara |
content_source |
UiTM Institutional Repository |
url_provider |
http://ir.uitm.edu.my/ |
language |
English |
topic |
Laboratories. General works Extraction (Chemistry) |
spellingShingle |
Laboratories. General works Extraction (Chemistry) Haron, Nazurah Determination of phenol in water sample using high performance liquid chromatography / Nazurah Haron |
description |
Phenol as in water is harmful to living organism yet have a toxicity effect for a long-term exposure. In this research, the analysis was achieved on a C18 column coupled with UV-vis detector (HPLC-UV) for determination of phenol in environmental water while by using solid phase extraction (SPE) as sample preparation technique. The optimized variable involved in SPE and HPLC were as follow: 3 mL was used for load sample volume in SPE, 45 ± 3 drops min-1 was used for sample drop-rate in SPE and 0.35 mL min-1 as flow-rate on eluent in HPLC. The analytical method was validated based on the following parameter: precision, linear range, limit of detection (LOD), limit of quantitation (LOQ) and bias/recovery. A good linear correlation coefficient with R2 = 0.9996 was observed over the range of 0.55 - 30.0 µg mL-1. Both repeatability and reproducibility (RSD, %) were 0.215 and 1.490, respectively. The limit of detection was calculated to be 0.212 µg mL-1, while the limit of quantitation value of the validated method was measured to be 0.642 µg mL-1. Good recoveries were between 81 - 120%. The proposed method was found to be suitable and precise for the determination of phenol in environmental water by using HPLC. |
format |
Student Project |
author |
Haron, Nazurah |
author_facet |
Haron, Nazurah |
author_sort |
Haron, Nazurah |
title |
Determination of phenol in water sample using high performance liquid chromatography / Nazurah Haron |
title_short |
Determination of phenol in water sample using high performance liquid chromatography / Nazurah Haron |
title_full |
Determination of phenol in water sample using high performance liquid chromatography / Nazurah Haron |
title_fullStr |
Determination of phenol in water sample using high performance liquid chromatography / Nazurah Haron |
title_full_unstemmed |
Determination of phenol in water sample using high performance liquid chromatography / Nazurah Haron |
title_sort |
determination of phenol in water sample using high performance liquid chromatography / nazurah haron |
publishDate |
2017 |
url |
http://ir.uitm.edu.my/id/eprint/35055/1/35055.pdf http://ir.uitm.edu.my/id/eprint/35055/ |
_version_ |
1685651259142438912 |
score |
13.211869 |