Comparison in detect the defects sizing using conventional ultrasonic testing and phased array ultrasonic testing (PAUT) / Nur Umairah Md Nor

This project gives a review for the comparison of Conventional Ultrasonic Testing and Phase Array Ultrasonic Testing methods in detecting and sizing defects in V-butt joint welds. The instrument used in this project is Omniscan MX2 for both techniques. For the probe, the criteria of selection for...

Full description

Saved in:
Bibliographic Details
Main Author: Md Nor, Nur Umairah
Format: Student Project
Language:English
Published: Faculty Of Applied Sciences 2017
Subjects:
Online Access:http://ir.uitm.edu.my/id/eprint/23682/1/PPb_NUR%20UMAIRAH%20MD%20NOR%20AS%20C%2017_5.PDF
http://ir.uitm.edu.my/id/eprint/23682/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uitm.ir.23682
record_format eprints
spelling my.uitm.ir.236822020-04-17T09:41:19Z http://ir.uitm.edu.my/id/eprint/23682/ Comparison in detect the defects sizing using conventional ultrasonic testing and phased array ultrasonic testing (PAUT) / Nur Umairah Md Nor Md Nor, Nur Umairah Composite materials Acoustics. Sound This project gives a review for the comparison of Conventional Ultrasonic Testing and Phase Array Ultrasonic Testing methods in detecting and sizing defects in V-butt joint welds. The instrument used in this project is Omniscan MX2 for both techniques. For the probe, the criteria of selection for Phased Array technique are frequency and the number of elements. Normally, the frequency is 5 MHz and the number of element used 32 elements. For Conventional technique, the addition of criteria is the angle used, which. is the angle set to 60°. The test samples used in this project are PL14960, PL14962 and PL14971. The types of these samples are V-butt weld plate and each sample has different type of artificial defect that are central line crack, slag inclusion and lack of side wall fusion (LOSWF). The results were evaluated based on the value of percentage error. This study proved that the percentage error for the slag inclusion using conventional techniques is 20% while using phased array technique is 36%. For LOSWF, the percentage error using conventional technique is 7.14% while using phased array technique is 17.9%. For central line crack, percentage error using conventional is 6.67%, while using phased array is 3.33%. It was proven that for slag inclusion and LOSWF, conventional technique provides a better sizing result compared with phased array technique. However for central line crack, phased array gives a better result compared with conventional. This may be influenced by the thickness of the plate and the way the inspector interpreted the data. Faculty Of Applied Sciences 2017 Student Project NonPeerReviewed text en http://ir.uitm.edu.my/id/eprint/23682/1/PPb_NUR%20UMAIRAH%20MD%20NOR%20AS%20C%2017_5.PDF Md Nor, Nur Umairah (2017) Comparison in detect the defects sizing using conventional ultrasonic testing and phased array ultrasonic testing (PAUT) / Nur Umairah Md Nor. [Student Project] (Unpublished)
institution Universiti Teknologi Mara
building Tun Abdul Razak Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Mara
content_source UiTM Institutional Repository
url_provider http://ir.uitm.edu.my/
language English
topic Composite materials
Acoustics. Sound
spellingShingle Composite materials
Acoustics. Sound
Md Nor, Nur Umairah
Comparison in detect the defects sizing using conventional ultrasonic testing and phased array ultrasonic testing (PAUT) / Nur Umairah Md Nor
description This project gives a review for the comparison of Conventional Ultrasonic Testing and Phase Array Ultrasonic Testing methods in detecting and sizing defects in V-butt joint welds. The instrument used in this project is Omniscan MX2 for both techniques. For the probe, the criteria of selection for Phased Array technique are frequency and the number of elements. Normally, the frequency is 5 MHz and the number of element used 32 elements. For Conventional technique, the addition of criteria is the angle used, which. is the angle set to 60°. The test samples used in this project are PL14960, PL14962 and PL14971. The types of these samples are V-butt weld plate and each sample has different type of artificial defect that are central line crack, slag inclusion and lack of side wall fusion (LOSWF). The results were evaluated based on the value of percentage error. This study proved that the percentage error for the slag inclusion using conventional techniques is 20% while using phased array technique is 36%. For LOSWF, the percentage error using conventional technique is 7.14% while using phased array technique is 17.9%. For central line crack, percentage error using conventional is 6.67%, while using phased array is 3.33%. It was proven that for slag inclusion and LOSWF, conventional technique provides a better sizing result compared with phased array technique. However for central line crack, phased array gives a better result compared with conventional. This may be influenced by the thickness of the plate and the way the inspector interpreted the data.
format Student Project
author Md Nor, Nur Umairah
author_facet Md Nor, Nur Umairah
author_sort Md Nor, Nur Umairah
title Comparison in detect the defects sizing using conventional ultrasonic testing and phased array ultrasonic testing (PAUT) / Nur Umairah Md Nor
title_short Comparison in detect the defects sizing using conventional ultrasonic testing and phased array ultrasonic testing (PAUT) / Nur Umairah Md Nor
title_full Comparison in detect the defects sizing using conventional ultrasonic testing and phased array ultrasonic testing (PAUT) / Nur Umairah Md Nor
title_fullStr Comparison in detect the defects sizing using conventional ultrasonic testing and phased array ultrasonic testing (PAUT) / Nur Umairah Md Nor
title_full_unstemmed Comparison in detect the defects sizing using conventional ultrasonic testing and phased array ultrasonic testing (PAUT) / Nur Umairah Md Nor
title_sort comparison in detect the defects sizing using conventional ultrasonic testing and phased array ultrasonic testing (paut) / nur umairah md nor
publisher Faculty Of Applied Sciences
publishDate 2017
url http://ir.uitm.edu.my/id/eprint/23682/1/PPb_NUR%20UMAIRAH%20MD%20NOR%20AS%20C%2017_5.PDF
http://ir.uitm.edu.my/id/eprint/23682/
_version_ 1685649763824828416
score 13.211869