Sewage sludge characterization and pyrolysis / Mohd Faizal Md Tawil
In this study, treated sewage sludge from Indah Water Pantai Dalam and Kolej Mawar waste water treatment plant were characterized for pyrolysis application to generate product oil for bio-fuel. The characterization analyses of sample were carried out according to the American Test Method (ASTM). Bas...
Saved in:
Main Author: | |
---|---|
Format: | Student Project |
Language: | English |
Published: |
Faculty of Applied Sciences
2009
|
Subjects: | |
Online Access: | http://ir.uitm.edu.my/id/eprint/23099/1/PPb_MOHD%20FAIZAL%20MD%20TAWIL%20AS%2009_5.pdf http://ir.uitm.edu.my/id/eprint/23099/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.uitm.ir.23099 |
---|---|
record_format |
eprints |
spelling |
my.uitm.ir.230992019-02-27T07:39:15Z http://ir.uitm.edu.my/id/eprint/23099/ Sewage sludge characterization and pyrolysis / Mohd Faizal Md Tawil Md Tawil, Mohd Faizal Sewage collection and disposal systems. Sewerage Sewage sludge In this study, treated sewage sludge from Indah Water Pantai Dalam and Kolej Mawar waste water treatment plant were characterized for pyrolysis application to generate product oil for bio-fuel. The characterization analyses of sample were carried out according to the American Test Method (ASTM). Based on the proximate and ultimate analysis data, both samples has a calorific value around 11±1 MJ/kg, ash content lower than volatile matter and low fixed carbon value, where sample from IWK Pantai Dalam was has the higher volatile matter and lowest ash content. Previous research was concluding that high volatile matter content with low ash content was the main criteria for pyrolysis. Based upon the fact, the pyrolysis of sample from IWK Pantai Dalam was performed in a flash pyrolysis reactor with four difference temperature 400°C, 500°C, 600°C, and 650°C. At temperature of 600°C the liquid oil yield was maximum (28.48 wt %) and afterwards began to decline. The liquid oil produce is alkali solution with high density and valuable calorific value. The liquid oil obtained at temperature 600°C was analyzed for its chemical compound by using FTIR and GCMS. Result showed that liquid oil contain a high proportion of alkane, alkene, and aromatic compounds that would be interesting in order to use the bio-oil in bio-fuel applications. Faculty of Applied Sciences 2009 Student Project NonPeerReviewed text en http://ir.uitm.edu.my/id/eprint/23099/1/PPb_MOHD%20FAIZAL%20MD%20TAWIL%20AS%2009_5.pdf Md Tawil, Mohd Faizal (2009) Sewage sludge characterization and pyrolysis / Mohd Faizal Md Tawil. [Student Project] (Unpublished) |
institution |
Universiti Teknologi Mara |
building |
Tun Abdul Razak Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Mara |
content_source |
UiTM Institutional Repository |
url_provider |
http://ir.uitm.edu.my/ |
language |
English |
topic |
Sewage collection and disposal systems. Sewerage Sewage sludge |
spellingShingle |
Sewage collection and disposal systems. Sewerage Sewage sludge Md Tawil, Mohd Faizal Sewage sludge characterization and pyrolysis / Mohd Faizal Md Tawil |
description |
In this study, treated sewage sludge from Indah Water Pantai Dalam and Kolej Mawar waste water treatment plant were characterized for pyrolysis application to generate product oil for bio-fuel. The characterization analyses of sample were carried out according to the American Test Method (ASTM). Based on the proximate and ultimate analysis data, both samples has a calorific value around 11±1 MJ/kg, ash content lower than volatile matter and low fixed carbon value, where sample from IWK Pantai Dalam was has the higher volatile matter and lowest ash content. Previous research was concluding that high volatile matter content with low ash content was the main criteria for pyrolysis. Based upon the fact, the pyrolysis of sample from IWK Pantai Dalam was performed in a flash pyrolysis reactor with four difference temperature 400°C, 500°C, 600°C, and 650°C. At temperature of 600°C the liquid oil yield was maximum (28.48 wt %) and afterwards began to decline. The liquid oil produce is alkali solution with high density and valuable calorific value. The liquid oil obtained at temperature 600°C was analyzed for its chemical compound by using FTIR and GCMS. Result showed that liquid oil contain a high proportion of alkane, alkene, and aromatic compounds that would be interesting in order to use the bio-oil in bio-fuel applications. |
format |
Student Project |
author |
Md Tawil, Mohd Faizal |
author_facet |
Md Tawil, Mohd Faizal |
author_sort |
Md Tawil, Mohd Faizal |
title |
Sewage sludge characterization and pyrolysis / Mohd Faizal Md Tawil |
title_short |
Sewage sludge characterization and pyrolysis / Mohd Faizal Md Tawil |
title_full |
Sewage sludge characterization and pyrolysis / Mohd Faizal Md Tawil |
title_fullStr |
Sewage sludge characterization and pyrolysis / Mohd Faizal Md Tawil |
title_full_unstemmed |
Sewage sludge characterization and pyrolysis / Mohd Faizal Md Tawil |
title_sort |
sewage sludge characterization and pyrolysis / mohd faizal md tawil |
publisher |
Faculty of Applied Sciences |
publishDate |
2009 |
url |
http://ir.uitm.edu.my/id/eprint/23099/1/PPb_MOHD%20FAIZAL%20MD%20TAWIL%20AS%2009_5.pdf http://ir.uitm.edu.my/id/eprint/23099/ |
_version_ |
1685649691850571776 |
score |
13.211869 |