Determination of air terminal for a structure by using rolling sphere method: article / Nurul Hasyimah Jusoh

Lightning is a one of the natural events that cannot be predicted when it occurs. When lightning strike any structural buildings or grounded objects can causes miscellaneous damage harm and fatality. In order to protect structure against lightning strikes and reduce the physical damage, properly des...

Full description

Saved in:
Bibliographic Details
Main Author: Jusoh, Nurul Hasyimah
Format: Article
Language:English
Published: 2013
Subjects:
Online Access:https://ir.uitm.edu.my/id/eprint/108504/1/108504.pdf
https://ir.uitm.edu.my/id/eprint/108504/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uitm.ir.108504
record_format eprints
spelling my.uitm.ir.1085042025-01-02T15:57:08Z https://ir.uitm.edu.my/id/eprint/108504/ Determination of air terminal for a structure by using rolling sphere method: article / Nurul Hasyimah Jusoh Jusoh, Nurul Hasyimah TK Electrical engineering. Electronics. Nuclear engineering Lightning is a one of the natural events that cannot be predicted when it occurs. When lightning strike any structural buildings or grounded objects can causes miscellaneous damage harm and fatality. In order to protect structure against lightning strikes and reduce the physical damage, properly designed of type and location for Lightning Protection System (LPS) should be carefully considered. The MS_IEC_62305_2007 standard clearly describe about selection and design of Lightning Protection System (LPS) with suggestion methods. So, this thesis that focus on determine the suitable location of air termination system for police station complex at Sri Hartamas, Kuala Lumpur to protect the structure in case of direct lightning strike. This thesis also present a graphical method performed by rolling sphere with specific radius. This is an imaginary sphere which is rolled over structure. In order to get accurate result, all parts of conventional Lightning Protection System (LPS) which is air termination system will be analyzed by using suitable computer software and followed the Malaysia Standard. For down conductor system and earth termination system will be analyzed based on Malaysia Standard. As a result, the structure are located in the radius of this method are protected from lightning strike. 2013 Article PeerReviewed text en https://ir.uitm.edu.my/id/eprint/108504/1/108504.pdf Determination of air terminal for a structure by using rolling sphere method: article / Nurul Hasyimah Jusoh. (2013) pp. 1-5.
institution Universiti Teknologi Mara
building Tun Abdul Razak Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Mara
content_source UiTM Institutional Repository
url_provider http://ir.uitm.edu.my/
language English
topic TK Electrical engineering. Electronics. Nuclear engineering
spellingShingle TK Electrical engineering. Electronics. Nuclear engineering
Jusoh, Nurul Hasyimah
Determination of air terminal for a structure by using rolling sphere method: article / Nurul Hasyimah Jusoh
description Lightning is a one of the natural events that cannot be predicted when it occurs. When lightning strike any structural buildings or grounded objects can causes miscellaneous damage harm and fatality. In order to protect structure against lightning strikes and reduce the physical damage, properly designed of type and location for Lightning Protection System (LPS) should be carefully considered. The MS_IEC_62305_2007 standard clearly describe about selection and design of Lightning Protection System (LPS) with suggestion methods. So, this thesis that focus on determine the suitable location of air termination system for police station complex at Sri Hartamas, Kuala Lumpur to protect the structure in case of direct lightning strike. This thesis also present a graphical method performed by rolling sphere with specific radius. This is an imaginary sphere which is rolled over structure. In order to get accurate result, all parts of conventional Lightning Protection System (LPS) which is air termination system will be analyzed by using suitable computer software and followed the Malaysia Standard. For down conductor system and earth termination system will be analyzed based on Malaysia Standard. As a result, the structure are located in the radius of this method are protected from lightning strike.
format Article
author Jusoh, Nurul Hasyimah
author_facet Jusoh, Nurul Hasyimah
author_sort Jusoh, Nurul Hasyimah
title Determination of air terminal for a structure by using rolling sphere method: article / Nurul Hasyimah Jusoh
title_short Determination of air terminal for a structure by using rolling sphere method: article / Nurul Hasyimah Jusoh
title_full Determination of air terminal for a structure by using rolling sphere method: article / Nurul Hasyimah Jusoh
title_fullStr Determination of air terminal for a structure by using rolling sphere method: article / Nurul Hasyimah Jusoh
title_full_unstemmed Determination of air terminal for a structure by using rolling sphere method: article / Nurul Hasyimah Jusoh
title_sort determination of air terminal for a structure by using rolling sphere method: article / nurul hasyimah jusoh
publishDate 2013
url https://ir.uitm.edu.my/id/eprint/108504/1/108504.pdf
https://ir.uitm.edu.my/id/eprint/108504/
_version_ 1821006435413131264
score 13.239859