Microwave holographic imaging technique for tumour detection

Early, accurate and efficient screening of tumour will go a long way to improve the life expectancy and quality of life. Microwave holographic technique uses nonionising radiation which has the potential to screen patients for tumour at low cost. It offers high contrast between healthy and malignant...

Full description

Saved in:
Bibliographic Details
Main Authors: Maniam, Jayanthy *, Narainasamy, Selvanathan, Abu-Bakar, M., Smith, D., Elgabroun, H. M., Yeong, P. M., Kumar, S. Senthil
Format: Article
Published: Springer 2007
Subjects:
Online Access:http://eprints.sunway.edu.my/39/
http://dx.doi.org/10.1007/978-3-540-68017-8_71
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.sunway.eprints.39
record_format eprints
spelling my.sunway.eprints.392017-02-07T02:39:38Z http://eprints.sunway.edu.my/39/ Microwave holographic imaging technique for tumour detection Maniam, Jayanthy * Narainasamy, Selvanathan Abu-Bakar, M. Smith, D. Elgabroun, H. M. Yeong, P. M. Kumar, S. Senthil QC Physics RC Internal medicine Early, accurate and efficient screening of tumour will go a long way to improve the life expectancy and quality of life. Microwave holographic technique uses nonionising radiation which has the potential to screen patients for tumour at low cost. It offers high contrast between healthy and malignant tissues and assists in forming image of the location and the extent of the malignant tissue. This technique exploits the advantages of holography without requiring the direct measurement which uses an expensive network analyser. This paper will investigate the use of an alternative microwave imaging technique using indirect holographic method. The use of continuous wave signal for imaging avoids the problems associated with pulsed systems. The use of two stage holographic technique requires recording of a holographic interference pattern as stage one and reconstruction of original image of the object as stage two. As a preliminary study, the transmitted microwave signal is bombarded on a suitable phantom and the scattered signals are measured. The significance of this technique is that it offers real time imaging possibility which can be used as intra operative imaging tool during the surgery to remove tumour Springer 2007 Article PeerReviewed Maniam, Jayanthy * and Narainasamy, Selvanathan and Abu-Bakar, M. and Smith, D. and Elgabroun, H. M. and Yeong, P. M. and Kumar, S. Senthil (2007) Microwave holographic imaging technique for tumour detection. IFMBE Proceedings, 15. pp. 275-277. http://dx.doi.org/10.1007/978-3-540-68017-8_71
institution Sunway University
building Sunway Campus Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Sunway University
content_source Sunway Institutional Repository
url_provider http://eprints.sunway.edu.my/
topic QC Physics
RC Internal medicine
spellingShingle QC Physics
RC Internal medicine
Maniam, Jayanthy *
Narainasamy, Selvanathan
Abu-Bakar, M.
Smith, D.
Elgabroun, H. M.
Yeong, P. M.
Kumar, S. Senthil
Microwave holographic imaging technique for tumour detection
description Early, accurate and efficient screening of tumour will go a long way to improve the life expectancy and quality of life. Microwave holographic technique uses nonionising radiation which has the potential to screen patients for tumour at low cost. It offers high contrast between healthy and malignant tissues and assists in forming image of the location and the extent of the malignant tissue. This technique exploits the advantages of holography without requiring the direct measurement which uses an expensive network analyser. This paper will investigate the use of an alternative microwave imaging technique using indirect holographic method. The use of continuous wave signal for imaging avoids the problems associated with pulsed systems. The use of two stage holographic technique requires recording of a holographic interference pattern as stage one and reconstruction of original image of the object as stage two. As a preliminary study, the transmitted microwave signal is bombarded on a suitable phantom and the scattered signals are measured. The significance of this technique is that it offers real time imaging possibility which can be used as intra operative imaging tool during the surgery to remove tumour
format Article
author Maniam, Jayanthy *
Narainasamy, Selvanathan
Abu-Bakar, M.
Smith, D.
Elgabroun, H. M.
Yeong, P. M.
Kumar, S. Senthil
author_facet Maniam, Jayanthy *
Narainasamy, Selvanathan
Abu-Bakar, M.
Smith, D.
Elgabroun, H. M.
Yeong, P. M.
Kumar, S. Senthil
author_sort Maniam, Jayanthy *
title Microwave holographic imaging technique for tumour detection
title_short Microwave holographic imaging technique for tumour detection
title_full Microwave holographic imaging technique for tumour detection
title_fullStr Microwave holographic imaging technique for tumour detection
title_full_unstemmed Microwave holographic imaging technique for tumour detection
title_sort microwave holographic imaging technique for tumour detection
publisher Springer
publishDate 2007
url http://eprints.sunway.edu.my/39/
http://dx.doi.org/10.1007/978-3-540-68017-8_71
_version_ 1644324223103008768
score 13.211869