Guttaflow bioseal versus monocone obturation technique. A scanning electron microscopy study
Background The understanding on how well GuttaFlow Bioseal (GFB) conforms to the root canal irregularities is unclear and requires further investigation. Purpose This study compared the obturated surface area, the extrusion of root filling material and the duration of obturation procedure between...
Saved in:
Main Authors: | , , , , , |
---|---|
Format: | Conference or Workshop Item |
Language: | English English English English |
Published: |
2019
|
Subjects: | |
Online Access: | http://irep.iium.edu.my/88467/1/Poster%20KRD%202019.pdf http://irep.iium.edu.my/88467/7/poster.pdf http://irep.iium.edu.my/88467/8/Certificate%20of%20Attendance%20%28Musliana%29.pdf http://irep.iium.edu.my/88467/9/WINNER%20FOR%20KRD%202019%20COMPETITION.pdf http://irep.iium.edu.my/88467/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.iium.irep.88467 |
---|---|
record_format |
dspace |
spelling |
my.iium.irep.884672021-03-15T02:50:52Z http://irep.iium.edu.my/88467/ Guttaflow bioseal versus monocone obturation technique. A scanning electron microscopy study Mustaffa, Musliana Nordin, Nuradlin Embong, Siti Nur Hanie Mahdan, Mohd Haidil Akmal Kharuddin, Azrul Fazwan Mohd Ibrahim, Mohamad Shafiq RK Dentistry Background The understanding on how well GuttaFlow Bioseal (GFB) conforms to the root canal irregularities is unclear and requires further investigation. Purpose This study compared the obturated surface area, the extrusion of root filling material and the duration of obturation procedure between GFB and monocone. Methodology The root canal of twenty single-rooted mandibular premolars were prepared using Hyflex CM rotary files (Coltène/Whaledent). The samples were equally divided into two groups; GFB and monocone. The duration of obturation procedure was evaluated using a digital timer and a radiograph was taken to assess the presence of extrusion. The roots were sectioned perpendicularly to obtain 3 root segments; apical 1/3, middle 1/3 and coronal 1/3. All resected roots were mounted on brass stubs, sputter-coated with thin gold coating and observed under scanning electron microscope (Zeiss EVO50, Germany) at 20x magnification. The images were transferred to the SketchAndCalc Area Calculator software for evaluation of obturated surface area. The data was analysed with SPSS version 25.0. Results The median score of obturated surface area between GFB and monocone at the apical 1/3 was 86.51 and 83.00, at the middle 1/3 was 90.48 and 87.35 and at the coronal 1/3 was 93.00 and 83.39 respectively with statistically significant difference at the coronal 1/3. The extrusion of root filling material between GFB and monocone did not show statistically significant difference. The mean score of duration of obturation procedure between GFB and monocone was 149.50 and 137.60 respectively with statistically significant difference. Conclusion The obturated surface area at the apical 1/3 and middle 1/3 between GFB and monocone was comparable but at the coronal 1/3 the former showed 11.5% better. The extrusion of root filling material between GFB and monocone was equivalent. The obturation procedure with GuttaFlow Bioseal required 8.6% longer than the monocone obturation technique. 2019-10-23 Conference or Workshop Item NonPeerReviewed application/pdf en http://irep.iium.edu.my/88467/1/Poster%20KRD%202019.pdf application/pdf en http://irep.iium.edu.my/88467/7/poster.pdf application/pdf en http://irep.iium.edu.my/88467/8/Certificate%20of%20Attendance%20%28Musliana%29.pdf application/pdf en http://irep.iium.edu.my/88467/9/WINNER%20FOR%20KRD%202019%20COMPETITION.pdf Mustaffa, Musliana and Nordin, Nuradlin and Embong, Siti Nur Hanie and Mahdan, Mohd Haidil Akmal and Kharuddin, Azrul Fazwan and Mohd Ibrahim, Mohamad Shafiq (2019) Guttaflow bioseal versus monocone obturation technique. A scanning electron microscopy study. In: Kuantan Research Day 2019, 23rd October 2019, Kuantan, Pahang. (Unpublished) |
institution |
Universiti Islam Antarabangsa Malaysia |
building |
IIUM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
International Islamic University Malaysia |
content_source |
IIUM Repository (IREP) |
url_provider |
http://irep.iium.edu.my/ |
language |
English English English English |
topic |
RK Dentistry |
spellingShingle |
RK Dentistry Mustaffa, Musliana Nordin, Nuradlin Embong, Siti Nur Hanie Mahdan, Mohd Haidil Akmal Kharuddin, Azrul Fazwan Mohd Ibrahim, Mohamad Shafiq Guttaflow bioseal versus monocone obturation technique. A scanning electron microscopy study |
description |
Background The understanding on how well GuttaFlow Bioseal (GFB) conforms to the root canal irregularities is unclear and requires further investigation.
Purpose This study compared the obturated surface area, the extrusion of root filling material and the duration of obturation procedure between GFB and monocone.
Methodology The root canal of twenty single-rooted mandibular premolars were prepared using Hyflex CM rotary files (Coltène/Whaledent). The samples were equally divided into two groups; GFB and monocone. The duration of obturation procedure was evaluated using a digital timer and a radiograph was taken to assess the presence of extrusion. The roots were sectioned perpendicularly to obtain 3 root segments; apical 1/3, middle 1/3 and coronal 1/3. All resected roots were mounted on brass stubs, sputter-coated with thin gold coating and observed under scanning electron microscope (Zeiss EVO50, Germany) at 20x magnification. The images were transferred to the SketchAndCalc Area Calculator software for evaluation of obturated surface area. The data was analysed with SPSS version 25.0. Results The median score of obturated surface area between GFB and monocone at the apical 1/3 was 86.51 and 83.00, at the middle 1/3 was 90.48 and 87.35 and at the coronal 1/3 was 93.00 and 83.39 respectively with statistically significant difference at the coronal 1/3. The extrusion of root filling material between GFB and monocone did not show statistically significant difference. The mean score of duration of obturation procedure between GFB and monocone was 149.50 and 137.60 respectively with statistically significant difference. Conclusion The obturated surface area at the apical 1/3 and middle 1/3 between GFB and monocone was comparable but at the coronal 1/3 the former showed 11.5% better. The extrusion of root filling material between GFB and monocone was equivalent. The obturation procedure with GuttaFlow Bioseal required 8.6% longer than the monocone obturation technique. |
format |
Conference or Workshop Item |
author |
Mustaffa, Musliana Nordin, Nuradlin Embong, Siti Nur Hanie Mahdan, Mohd Haidil Akmal Kharuddin, Azrul Fazwan Mohd Ibrahim, Mohamad Shafiq |
author_facet |
Mustaffa, Musliana Nordin, Nuradlin Embong, Siti Nur Hanie Mahdan, Mohd Haidil Akmal Kharuddin, Azrul Fazwan Mohd Ibrahim, Mohamad Shafiq |
author_sort |
Mustaffa, Musliana |
title |
Guttaflow bioseal versus monocone obturation technique. A scanning electron microscopy study |
title_short |
Guttaflow bioseal versus monocone obturation technique. A scanning electron microscopy study |
title_full |
Guttaflow bioseal versus monocone obturation technique. A scanning electron microscopy study |
title_fullStr |
Guttaflow bioseal versus monocone obturation technique. A scanning electron microscopy study |
title_full_unstemmed |
Guttaflow bioseal versus monocone obturation technique. A scanning electron microscopy study |
title_sort |
guttaflow bioseal versus monocone obturation technique. a scanning electron microscopy study |
publishDate |
2019 |
url |
http://irep.iium.edu.my/88467/1/Poster%20KRD%202019.pdf http://irep.iium.edu.my/88467/7/poster.pdf http://irep.iium.edu.my/88467/8/Certificate%20of%20Attendance%20%28Musliana%29.pdf http://irep.iium.edu.my/88467/9/WINNER%20FOR%20KRD%202019%20COMPETITION.pdf http://irep.iium.edu.my/88467/ |
_version_ |
1695530650938900480 |
score |
13.211869 |