Simultaneous microbeam IBA and beam-induced luminescence analysis of strained doped silica fibre radiation dosimeters

We demonstrate that the simultaneous combination of ion beam analysis (IBA) and ion beam induced luminescence (IL) can reveal valuable information concerning the performance of strained doped silica fibre thermoluminescence microdosimeters. The micron scale spatial resolution and low detection limit...