Airborne particulate matters and microorganisms in library: An introduction of disinfection method towards safe and health indoor environment

Laboratory usually refers to a room or building equipped with chemicals and biological agents for scientific experimentation and research. Due to its own indoor hazards and its cause of health implications, it is an urge to assess and to understand the physical indoor air quality (IAQ) characteristi...

Full description

Saved in:
Bibliographic Details
Main Authors: A. H., Hazrin, A., Hizrri, A. A., Anis Syazana, H., Khadijah, Nordin, Noor Faizul Hadry, A., Norhidayah, Mohd Aris, Mohd Shukri
Format: Monograph
Language:English
Published: 2016
Subjects:
Online Access:http://irep.iium.edu.my/65311/1/EndofProjectReportForm_EDWB_2016.pdf
http://irep.iium.edu.my/65311/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.iium.irep.65311
record_format dspace
spelling my.iium.irep.653112023-02-23T06:33:36Z http://irep.iium.edu.my/65311/ Airborne particulate matters and microorganisms in library: An introduction of disinfection method towards safe and health indoor environment A. H., Hazrin A., Hizrri A. A., Anis Syazana H., Khadijah Nordin, Noor Faizul Hadry A., Norhidayah Mohd Aris, Mohd Shukri RA0421 Public health. Hygiene. Preventive Medicine RA1190 Toxicology Laboratory usually refers to a room or building equipped with chemicals and biological agents for scientific experimentation and research. Due to its own indoor hazards and its cause of health implications, it is an urge to assess and to understand the physical indoor air quality (IAQ) characteristics in the laboratory and the variables affecting the degree of exposure to occupants. The main objectives of this study was aimed to assess and to compare the physical IAQ characteristics and airborne pollutants including particulate matters (PM) and gaseous pollutants between laboratories, to identify microbial contaminants via bacterial counts as well as scientific bacterial-kits species identification and to correlate the relationship of physical IAQ characteristics, airborne pollutants and microbial contaminants between different laboratory settings within the same building which are Natural Product (NP) laboratory, Plant Tissue Culture (PTC) laboratory, and Microbiology laboratory. The physical IAQ characteristics and airborne PM was measured using VelociCalc multi-function ventilation meter 9565 and DustMate environmental dust detector respectively. Surface Air System Indoor Air Quality (SAS IAQ) was used to capture the microbial contaminants and after that bacterial counting and identification were done. The scientific method protocol and standard reference limits were compared based on Industrial Code of Practice on Indoor Air Quality (ICOP) (2010) regulated by the Department of Occupational Safety and Health (DOSH). The temperature of PTC laboratory, velocity of NP laboratory and Microbiology laboratory, the respirable particulate matter (PM) of all three laboratories and Colony Forming Unit (CFU) count of PTC and NP laboratory exceeded the standard limit regulated by DOSH. This study demonstrated that Gemella morbillorum is the common bacterial species available in the environment with poor IAQ and there is a significant relationship between physical characteristics, airborne pollutants and microbial contaminants between the different types of laboratory settings. In conclusion, priority should be given to NP laboratory as it is exposed to poor IAQ conditions and immediate action should be taken to eliminate the problems. Keywords: Indoor air quality (IAQ), laboratory, airborne pollutants, particulate matter (PM), microbes, CFU 2016-08-31 Monograph NonPeerReviewed application/pdf en http://irep.iium.edu.my/65311/1/EndofProjectReportForm_EDWB_2016.pdf A. H., Hazrin and A., Hizrri and A. A., Anis Syazana and H., Khadijah and Nordin, Noor Faizul Hadry and A., Norhidayah and Mohd Aris, Mohd Shukri (2016) Airborne particulate matters and microorganisms in library: An introduction of disinfection method towards safe and health indoor environment. UNSPECIFIED. UNSPECIFIED. (Unpublished)
institution Universiti Islam Antarabangsa Malaysia
building IIUM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider International Islamic University Malaysia
content_source IIUM Repository (IREP)
url_provider http://irep.iium.edu.my/
language English
topic RA0421 Public health. Hygiene. Preventive Medicine
RA1190 Toxicology
spellingShingle RA0421 Public health. Hygiene. Preventive Medicine
RA1190 Toxicology
A. H., Hazrin
A., Hizrri
A. A., Anis Syazana
H., Khadijah
Nordin, Noor Faizul Hadry
A., Norhidayah
Mohd Aris, Mohd Shukri
Airborne particulate matters and microorganisms in library: An introduction of disinfection method towards safe and health indoor environment
description Laboratory usually refers to a room or building equipped with chemicals and biological agents for scientific experimentation and research. Due to its own indoor hazards and its cause of health implications, it is an urge to assess and to understand the physical indoor air quality (IAQ) characteristics in the laboratory and the variables affecting the degree of exposure to occupants. The main objectives of this study was aimed to assess and to compare the physical IAQ characteristics and airborne pollutants including particulate matters (PM) and gaseous pollutants between laboratories, to identify microbial contaminants via bacterial counts as well as scientific bacterial-kits species identification and to correlate the relationship of physical IAQ characteristics, airborne pollutants and microbial contaminants between different laboratory settings within the same building which are Natural Product (NP) laboratory, Plant Tissue Culture (PTC) laboratory, and Microbiology laboratory. The physical IAQ characteristics and airborne PM was measured using VelociCalc multi-function ventilation meter 9565 and DustMate environmental dust detector respectively. Surface Air System Indoor Air Quality (SAS IAQ) was used to capture the microbial contaminants and after that bacterial counting and identification were done. The scientific method protocol and standard reference limits were compared based on Industrial Code of Practice on Indoor Air Quality (ICOP) (2010) regulated by the Department of Occupational Safety and Health (DOSH). The temperature of PTC laboratory, velocity of NP laboratory and Microbiology laboratory, the respirable particulate matter (PM) of all three laboratories and Colony Forming Unit (CFU) count of PTC and NP laboratory exceeded the standard limit regulated by DOSH. This study demonstrated that Gemella morbillorum is the common bacterial species available in the environment with poor IAQ and there is a significant relationship between physical characteristics, airborne pollutants and microbial contaminants between the different types of laboratory settings. In conclusion, priority should be given to NP laboratory as it is exposed to poor IAQ conditions and immediate action should be taken to eliminate the problems. Keywords: Indoor air quality (IAQ), laboratory, airborne pollutants, particulate matter (PM), microbes, CFU
format Monograph
author A. H., Hazrin
A., Hizrri
A. A., Anis Syazana
H., Khadijah
Nordin, Noor Faizul Hadry
A., Norhidayah
Mohd Aris, Mohd Shukri
author_facet A. H., Hazrin
A., Hizrri
A. A., Anis Syazana
H., Khadijah
Nordin, Noor Faizul Hadry
A., Norhidayah
Mohd Aris, Mohd Shukri
author_sort A. H., Hazrin
title Airborne particulate matters and microorganisms in library: An introduction of disinfection method towards safe and health indoor environment
title_short Airborne particulate matters and microorganisms in library: An introduction of disinfection method towards safe and health indoor environment
title_full Airborne particulate matters and microorganisms in library: An introduction of disinfection method towards safe and health indoor environment
title_fullStr Airborne particulate matters and microorganisms in library: An introduction of disinfection method towards safe and health indoor environment
title_full_unstemmed Airborne particulate matters and microorganisms in library: An introduction of disinfection method towards safe and health indoor environment
title_sort airborne particulate matters and microorganisms in library: an introduction of disinfection method towards safe and health indoor environment
publishDate 2016
url http://irep.iium.edu.my/65311/1/EndofProjectReportForm_EDWB_2016.pdf
http://irep.iium.edu.my/65311/
_version_ 1758950185963094016
score 13.211869