WAVE TRANSMISSION ON SUBMERGED BREAKWATER USING INTERLOCKING CONCRETE UNIT (ICU-V)

Coastal areas are currently facing serious problems of erosion. Urgent protection is needed in order to cater these alarming problems. Submerged breakwater is one of the protections that can be used to reduce the erosion. This type of breakwater widely used all over the world. This research deals wi...

Full description

Saved in:
Bibliographic Details
Main Author: Abdullah, Siti Nur Hanis
Format: Final Year Project
Language:English
Published: Universiti Teknologi PETRONAS 2013
Subjects:
Online Access:http://utpedia.utp.edu.my/8176/1/Final%20Dissertation.doc
http://utpedia.utp.edu.my/8176/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-utp-utpedia.8176
record_format eprints
spelling my-utp-utpedia.81762013-10-04T15:29:55Z http://utpedia.utp.edu.my/8176/ WAVE TRANSMISSION ON SUBMERGED BREAKWATER USING INTERLOCKING CONCRETE UNIT (ICU-V) Abdullah, Siti Nur Hanis TA Engineering (General). Civil engineering (General) Coastal areas are currently facing serious problems of erosion. Urgent protection is needed in order to cater these alarming problems. Submerged breakwater is one of the protections that can be used to reduce the erosion. This type of breakwater widely used all over the world. This research deals with submerged breakwater that armored with interlocking concrete unit (ICU-V). The objectives of this research are to investigate the relationship between the variables of the factors affecting wave attenuation, to compare the theoretical values and experimental values and to produce an effective and optimum design of submerged breakwaters with interlocking concrete unit (ICU-V). Laboratory experiment on submerged breakwater using interlocking concrete unit (ICU-V) with 108 tests for this research were analyzed. The varied parameters were wave period (T), wave height; water depth (d) and width crest (B). The experiment tests were conducted in a wave flume 23m long and 2 m wide. The result from this laboratory experiment has been compared with the previous researchers. The results shown that the two variables that been investigated in this laboratory experiment which are depth of submergence and crest width do have effect on the wave attenuation. Wave attenuation is inversely proportional with the crest width but directly proportional with the relative crest elevation. Transmission coefficients derived from the experimental results are reasonably comparable with the theoretical values calculated based on Tomasicchio and D'Alessandro. Universiti Teknologi PETRONAS 2013-08 Final Year Project NonPeerReviewed application/pdf en http://utpedia.utp.edu.my/8176/1/Final%20Dissertation.doc Abdullah, Siti Nur Hanis (2013) WAVE TRANSMISSION ON SUBMERGED BREAKWATER USING INTERLOCKING CONCRETE UNIT (ICU-V). Universiti Teknologi PETRONAS. (Unpublished)
institution Universiti Teknologi Petronas
building UTP Resource Centre
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Petronas
content_source UTP Electronic and Digitized Intellectual Asset
url_provider http://utpedia.utp.edu.my/
language English
topic TA Engineering (General). Civil engineering (General)
spellingShingle TA Engineering (General). Civil engineering (General)
Abdullah, Siti Nur Hanis
WAVE TRANSMISSION ON SUBMERGED BREAKWATER USING INTERLOCKING CONCRETE UNIT (ICU-V)
description Coastal areas are currently facing serious problems of erosion. Urgent protection is needed in order to cater these alarming problems. Submerged breakwater is one of the protections that can be used to reduce the erosion. This type of breakwater widely used all over the world. This research deals with submerged breakwater that armored with interlocking concrete unit (ICU-V). The objectives of this research are to investigate the relationship between the variables of the factors affecting wave attenuation, to compare the theoretical values and experimental values and to produce an effective and optimum design of submerged breakwaters with interlocking concrete unit (ICU-V). Laboratory experiment on submerged breakwater using interlocking concrete unit (ICU-V) with 108 tests for this research were analyzed. The varied parameters were wave period (T), wave height; water depth (d) and width crest (B). The experiment tests were conducted in a wave flume 23m long and 2 m wide. The result from this laboratory experiment has been compared with the previous researchers. The results shown that the two variables that been investigated in this laboratory experiment which are depth of submergence and crest width do have effect on the wave attenuation. Wave attenuation is inversely proportional with the crest width but directly proportional with the relative crest elevation. Transmission coefficients derived from the experimental results are reasonably comparable with the theoretical values calculated based on Tomasicchio and D'Alessandro.
format Final Year Project
author Abdullah, Siti Nur Hanis
author_facet Abdullah, Siti Nur Hanis
author_sort Abdullah, Siti Nur Hanis
title WAVE TRANSMISSION ON SUBMERGED BREAKWATER USING INTERLOCKING CONCRETE UNIT (ICU-V)
title_short WAVE TRANSMISSION ON SUBMERGED BREAKWATER USING INTERLOCKING CONCRETE UNIT (ICU-V)
title_full WAVE TRANSMISSION ON SUBMERGED BREAKWATER USING INTERLOCKING CONCRETE UNIT (ICU-V)
title_fullStr WAVE TRANSMISSION ON SUBMERGED BREAKWATER USING INTERLOCKING CONCRETE UNIT (ICU-V)
title_full_unstemmed WAVE TRANSMISSION ON SUBMERGED BREAKWATER USING INTERLOCKING CONCRETE UNIT (ICU-V)
title_sort wave transmission on submerged breakwater using interlocking concrete unit (icu-v)
publisher Universiti Teknologi PETRONAS
publishDate 2013
url http://utpedia.utp.edu.my/8176/1/Final%20Dissertation.doc
http://utpedia.utp.edu.my/8176/
_version_ 1739831546372685824
score 13.222552