PARTIAL STROKE TEST OF EMERGENCY SHUTDOWN VALVE-METSO NELES
Potential disasters at an industrial processing plant may include an accident resulting in a massive release of toxic materials, an uncontrollable reactant, a devastating explosion or any combination of the above. All processing plant must be guarded from all potential disaster scenarios. Therefo...
Saved in:
Main Author: | |
---|---|
Format: | Final Year Project |
Language: | English |
Published: |
Universiti Teknologi PETRONAS
2009
|
Subjects: | |
Online Access: | http://utpedia.utp.edu.my/7983/1/2009%20-%20Partial%20stroke%20test%20of%20emergency%20shutdown%20valve-metso%20neles.pdf http://utpedia.utp.edu.my/7983/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my-utp-utpedia.7983 |
---|---|
record_format |
eprints |
spelling |
my-utp-utpedia.79832017-01-25T09:43:57Z http://utpedia.utp.edu.my/7983/ PARTIAL STROKE TEST OF EMERGENCY SHUTDOWN VALVE-METSO NELES Sudarman, Siti Farhana TK Electrical engineering. Electronics Nuclear engineering Potential disasters at an industrial processing plant may include an accident resulting in a massive release of toxic materials, an uncontrollable reactant, a devastating explosion or any combination of the above. All processing plant must be guarded from all potential disaster scenarios. Therefore , emergency shutdown valves has to be sure be operated with fault-free as the valves are kept idle in open position for long periods and are designed to close and keep tight in case of a hazard occur. Regular checking has to be perfonned in order to guarantee the function of the valves. Emergency Shutdown valves have been tested at unit turnaround, using a Full Stroke Testing and Partial Stroke Testing to demonstrate the perfonnance. The scope of this project is to verify the technology needed for Full Stroke Testing and Partial Stroke Testing in order to ensure the perfonnance of the Emergency Shutdown valve. The testing is simulated by using WideField2 Software (YOKOGAWA) for Full Stroke Test and FieldCare Software (Metso Neles) for Partial Stroke Test. Partial Stroke Testing can be a good complement to Full Stroke Testing as it reduces the required Full Stroke Testing frequency and associated operational impact. Partial Stroke Testing will detect failure of Emergency Shutdown valves without disturbing the process flow. Testing is conducted for sixth times. The valve status and its response to mechanical movement during the test are monitored. Valve perfonnance trend is analyzed after each partial stroke test to find whether there is any potential of valve failure. The result of valve test, pneumatics test, breakdown pressure and load factor are being taken into consideration in analyzing the perfonnance of the emergency shutdown valve. Universiti Teknologi PETRONAS 2009-12 Final Year Project NonPeerReviewed application/pdf en http://utpedia.utp.edu.my/7983/1/2009%20-%20Partial%20stroke%20test%20of%20emergency%20shutdown%20valve-metso%20neles.pdf Sudarman, Siti Farhana (2009) PARTIAL STROKE TEST OF EMERGENCY SHUTDOWN VALVE-METSO NELES. Universiti Teknologi PETRONAS. (Unpublished) |
institution |
Universiti Teknologi Petronas |
building |
UTP Resource Centre |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Petronas |
content_source |
UTP Electronic and Digitized Intellectual Asset |
url_provider |
http://utpedia.utp.edu.my/ |
language |
English |
topic |
TK Electrical engineering. Electronics Nuclear engineering |
spellingShingle |
TK Electrical engineering. Electronics Nuclear engineering Sudarman, Siti Farhana PARTIAL STROKE TEST OF EMERGENCY SHUTDOWN VALVE-METSO NELES |
description |
Potential disasters at an industrial processing plant may include an accident
resulting in a massive release of toxic materials, an uncontrollable reactant, a
devastating explosion or any combination of the above. All processing plant must be
guarded from all potential disaster scenarios. Therefore , emergency shutdown valves
has to be sure be operated with fault-free as the valves are kept idle in open position
for long periods and are designed to close and keep tight in case of a hazard occur.
Regular checking has to be perfonned in order to guarantee the function of the valves.
Emergency Shutdown valves have been tested at unit turnaround, using a Full Stroke
Testing and Partial Stroke Testing to demonstrate the perfonnance. The scope of this
project is to verify the technology needed for Full Stroke Testing and Partial Stroke
Testing in order to ensure the perfonnance of the Emergency Shutdown valve. The
testing is simulated by using WideField2 Software (YOKOGAWA) for Full Stroke
Test and FieldCare Software (Metso Neles) for Partial Stroke Test. Partial Stroke
Testing can be a good complement to Full Stroke Testing as it reduces the required
Full Stroke Testing frequency and associated operational impact. Partial Stroke
Testing will detect failure of Emergency Shutdown valves without disturbing the
process flow. Testing is conducted for sixth times. The valve status and its response
to mechanical movement during the test are monitored. Valve perfonnance trend is
analyzed after each partial stroke test to find whether there is any potential of valve
failure. The result of valve test, pneumatics test, breakdown pressure and load factor
are being taken into consideration in analyzing the perfonnance of the emergency
shutdown valve. |
format |
Final Year Project |
author |
Sudarman, Siti Farhana |
author_facet |
Sudarman, Siti Farhana |
author_sort |
Sudarman, Siti Farhana |
title |
PARTIAL STROKE TEST OF EMERGENCY SHUTDOWN VALVE-METSO NELES |
title_short |
PARTIAL STROKE TEST OF EMERGENCY SHUTDOWN VALVE-METSO NELES |
title_full |
PARTIAL STROKE TEST OF EMERGENCY SHUTDOWN VALVE-METSO NELES |
title_fullStr |
PARTIAL STROKE TEST OF EMERGENCY SHUTDOWN VALVE-METSO NELES |
title_full_unstemmed |
PARTIAL STROKE TEST OF EMERGENCY SHUTDOWN VALVE-METSO NELES |
title_sort |
partial stroke test of emergency shutdown valve-metso neles |
publisher |
Universiti Teknologi PETRONAS |
publishDate |
2009 |
url |
http://utpedia.utp.edu.my/7983/1/2009%20-%20Partial%20stroke%20test%20of%20emergency%20shutdown%20valve-metso%20neles.pdf http://utpedia.utp.edu.my/7983/ |
_version_ |
1739831528434696192 |
score |
13.211869 |