Third Harmonic Filter Design in Mitigating High Current At the Generator Neutral

Harmonic is commonly known power quality problem which caused by non-linear load. Nevertheless, harmonic was also found at the synchronous generator instead of at the load. The effect of the triplen harmonic to the generator neutral is high current which lead to high temperature of the component at...

Full description

Saved in:
Bibliographic Details
Main Author: GHAZALI, NUR AFIFAH
Format: Final Year Project
Language:English
Published: IRC 2016
Subjects:
Online Access:http://utpedia.utp.edu.my/17118/1/FYP%202%20Final%20report.pdf
http://utpedia.utp.edu.my/17118/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-utp-utpedia.17118
record_format eprints
spelling my-utp-utpedia.171182017-01-25T09:34:34Z http://utpedia.utp.edu.my/17118/ Third Harmonic Filter Design in Mitigating High Current At the Generator Neutral GHAZALI, NUR AFIFAH TK Electrical engineering. Electronics Nuclear engineering Harmonic is commonly known power quality problem which caused by non-linear load. Nevertheless, harmonic was also found at the synchronous generator instead of at the load. The effect of the triplen harmonic to the generator neutral is high current which lead to high temperature of the component at the generator neutral. Recent researches had identified the major component of the triplen harmonic is third harmonic which initiated by the synchronous generator itself. There are numerous techniques to reduce the effect of harmonic in power system network. By installing harmonic filter is one of the techniques to mitigate the harmonic current. A study about installing harmonic filter at the generator neutral had been introduced to counter this arising issue. The objectives of this study are to study the various harmonic filters used in mitigating the third harmonic current and to design harmonic filter that can reduced the third harmonic current at generator neutral and validate the modelling with experimental values IRC 2016-01 Final Year Project NonPeerReviewed application/pdf en http://utpedia.utp.edu.my/17118/1/FYP%202%20Final%20report.pdf GHAZALI, NUR AFIFAH (2016) Third Harmonic Filter Design in Mitigating High Current At the Generator Neutral. IRC, Universiti Teknologi PETRONAS. (Submitted)
institution Universiti Teknologi Petronas
building UTP Resource Centre
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Petronas
content_source UTP Electronic and Digitized Intellectual Asset
url_provider http://utpedia.utp.edu.my/
language English
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
GHAZALI, NUR AFIFAH
Third Harmonic Filter Design in Mitigating High Current At the Generator Neutral
description Harmonic is commonly known power quality problem which caused by non-linear load. Nevertheless, harmonic was also found at the synchronous generator instead of at the load. The effect of the triplen harmonic to the generator neutral is high current which lead to high temperature of the component at the generator neutral. Recent researches had identified the major component of the triplen harmonic is third harmonic which initiated by the synchronous generator itself. There are numerous techniques to reduce the effect of harmonic in power system network. By installing harmonic filter is one of the techniques to mitigate the harmonic current. A study about installing harmonic filter at the generator neutral had been introduced to counter this arising issue. The objectives of this study are to study the various harmonic filters used in mitigating the third harmonic current and to design harmonic filter that can reduced the third harmonic current at generator neutral and validate the modelling with experimental values
format Final Year Project
author GHAZALI, NUR AFIFAH
author_facet GHAZALI, NUR AFIFAH
author_sort GHAZALI, NUR AFIFAH
title Third Harmonic Filter Design in Mitigating High Current At the Generator Neutral
title_short Third Harmonic Filter Design in Mitigating High Current At the Generator Neutral
title_full Third Harmonic Filter Design in Mitigating High Current At the Generator Neutral
title_fullStr Third Harmonic Filter Design in Mitigating High Current At the Generator Neutral
title_full_unstemmed Third Harmonic Filter Design in Mitigating High Current At the Generator Neutral
title_sort third harmonic filter design in mitigating high current at the generator neutral
publisher IRC
publishDate 2016
url http://utpedia.utp.edu.my/17118/1/FYP%202%20Final%20report.pdf
http://utpedia.utp.edu.my/17118/
_version_ 1739832347136622592
score 13.211869