Harmonic Study on UTP New Building Network

In this study, frequency scan analysis and harmonic resonance modal analysis are two techniques that have been chosen to analyse the present of resonance in a network. The presence of resonance is the factor that contributes to the amplification of harmonic which exist along with the current from...

Full description

Saved in:
Bibliographic Details
Main Author: Mohd Aziz, Wan Shahira
Format: Final Year Project
Language:English
Published: IRC 2016
Subjects:
Online Access:http://utpedia.utp.edu.my/17088/1/Final%20Dissertation_16435.pdf
http://utpedia.utp.edu.my/17088/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-utp-utpedia.17088
record_format eprints
spelling my-utp-utpedia.170882017-01-25T09:34:38Z http://utpedia.utp.edu.my/17088/ Harmonic Study on UTP New Building Network Mohd Aziz, Wan Shahira TK Electrical engineering. Electronics Nuclear engineering In this study, frequency scan analysis and harmonic resonance modal analysis are two techniques that have been chosen to analyse the present of resonance in a network. The presence of resonance is the factor that contributes to the amplification of harmonic which exist along with the current from non-linear load. Harmonic that occurs contributes to several negative effects to the power system and has potential to cause the equipment to damage. Universiti Teknologi PETRONAS (UTP) new building network, or to be more specific, the network at new academic buildings is an interesting place to conduct this study. This is because in UTP there are various types of electrical machines, high voltage machines and high technology computers and equipments especially in block 5,17 and 22; that may contribute to harmonic. The whole UTP network is first simplified and the cable is present in pi impedance form. After that, the power flow study of the network is conducted using a MATLAB Simulink. The potential resonance from UTP network is analysed using the two techniques that have been mentioned above. The techniques are also run using MATLAB. The measurement of harmonic current and voltage at the respective buildings are then performed for six (6) days at the sub switch board (SSB) of the three blocks that have been chosen as the case studies. The data obtained from the data logging are compared with the data obtained using the two techniques mentioned earlier. The expected results are high harmonics is present at the harmonic frequencies which are high in resonance. IRC 2016-01 Final Year Project NonPeerReviewed application/pdf en http://utpedia.utp.edu.my/17088/1/Final%20Dissertation_16435.pdf Mohd Aziz, Wan Shahira (2016) Harmonic Study on UTP New Building Network. IRC, Universiti Teknologi PETRONAS. (Submitted)
institution Universiti Teknologi Petronas
building UTP Resource Centre
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Petronas
content_source UTP Electronic and Digitized Intellectual Asset
url_provider http://utpedia.utp.edu.my/
language English
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Mohd Aziz, Wan Shahira
Harmonic Study on UTP New Building Network
description In this study, frequency scan analysis and harmonic resonance modal analysis are two techniques that have been chosen to analyse the present of resonance in a network. The presence of resonance is the factor that contributes to the amplification of harmonic which exist along with the current from non-linear load. Harmonic that occurs contributes to several negative effects to the power system and has potential to cause the equipment to damage. Universiti Teknologi PETRONAS (UTP) new building network, or to be more specific, the network at new academic buildings is an interesting place to conduct this study. This is because in UTP there are various types of electrical machines, high voltage machines and high technology computers and equipments especially in block 5,17 and 22; that may contribute to harmonic. The whole UTP network is first simplified and the cable is present in pi impedance form. After that, the power flow study of the network is conducted using a MATLAB Simulink. The potential resonance from UTP network is analysed using the two techniques that have been mentioned above. The techniques are also run using MATLAB. The measurement of harmonic current and voltage at the respective buildings are then performed for six (6) days at the sub switch board (SSB) of the three blocks that have been chosen as the case studies. The data obtained from the data logging are compared with the data obtained using the two techniques mentioned earlier. The expected results are high harmonics is present at the harmonic frequencies which are high in resonance.
format Final Year Project
author Mohd Aziz, Wan Shahira
author_facet Mohd Aziz, Wan Shahira
author_sort Mohd Aziz, Wan Shahira
title Harmonic Study on UTP New Building Network
title_short Harmonic Study on UTP New Building Network
title_full Harmonic Study on UTP New Building Network
title_fullStr Harmonic Study on UTP New Building Network
title_full_unstemmed Harmonic Study on UTP New Building Network
title_sort harmonic study on utp new building network
publisher IRC
publishDate 2016
url http://utpedia.utp.edu.my/17088/1/Final%20Dissertation_16435.pdf
http://utpedia.utp.edu.my/17088/
_version_ 1739832343282057216
score 13.211869