Analysis Of The Air Distribution Through Ventilation Duct In Block 13 Lecturers’s Office Space
The indoor environmental factors considered in office building must be determined in order to meet user’s requirement. Disruption of indoor environment may constitute to reduce occupants’ efficiency and work productivity. Observations of the temperature were performed at lecturer’s office in block 1...
Saved in:
Main Author: | |
---|---|
Format: | Final Year Project |
Language: | English |
Published: |
Universiti Teknologi Petronas
2010
|
Subjects: | |
Online Access: | http://utpedia.utp.edu.my/1381/1/AHMIR_B_MOHD_NAZRI.pdf http://utpedia.utp.edu.my/1381/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my-utp-utpedia.1381 |
---|---|
record_format |
eprints |
spelling |
my-utp-utpedia.13812017-01-25T09:43:07Z http://utpedia.utp.edu.my/1381/ Analysis Of The Air Distribution Through Ventilation Duct In Block 13 Lecturers’s Office Space Ahmir B Mohd Nazri, Ahmir TP Chemical technology The indoor environmental factors considered in office building must be determined in order to meet user’s requirement. Disruption of indoor environment may constitute to reduce occupants’ efficiency and work productivity. Observations of the temperature were performed at lecturer’s office in block 13 and found that the cooling load varies from early morning till evening indicating the cooling requirement of different load. The objective of this study is to analyze the response of the AHU units response to the variable cooling load. The AHU system should respond to the cooling requirement through the varies component such as blower speed control, VAV position , temperature detector and etc. The study undertaken in this project measures temperature and air flow velocity in order to determine the behavior of the AHU system. The fluid dynamic of the system was simulated using Fluent. The results show that the AHU increases the flow rate of the cooled air when cooling load is high. Universiti Teknologi Petronas 2010 Final Year Project NonPeerReviewed application/pdf en http://utpedia.utp.edu.my/1381/1/AHMIR_B_MOHD_NAZRI.pdf Ahmir B Mohd Nazri, Ahmir (2010) Analysis Of The Air Distribution Through Ventilation Duct In Block 13 Lecturers’s Office Space. Universiti Teknologi Petronas. (Unpublished) |
institution |
Universiti Teknologi Petronas |
building |
UTP Resource Centre |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Petronas |
content_source |
UTP Electronic and Digitized Intellectual Asset |
url_provider |
http://utpedia.utp.edu.my/ |
language |
English |
topic |
TP Chemical technology |
spellingShingle |
TP Chemical technology Ahmir B Mohd Nazri, Ahmir Analysis Of The Air Distribution Through Ventilation Duct In Block 13 Lecturers’s Office Space |
description |
The indoor environmental factors considered in office building must be determined in order to meet user’s requirement. Disruption of indoor environment may constitute to reduce occupants’ efficiency and work productivity. Observations of the temperature were performed at lecturer’s office in block 13 and found that the cooling load varies from early morning till evening indicating the cooling requirement of different load. The objective of this study is to analyze the response of the AHU units response to the variable cooling load. The AHU system should respond to the cooling requirement through the varies component such as blower speed control, VAV position , temperature detector and etc. The study undertaken in this project measures temperature and air flow velocity in order to determine the behavior of the AHU system. The fluid dynamic of the system was simulated using Fluent. The results show that the AHU increases the flow rate of the cooled air when cooling load is high. |
format |
Final Year Project |
author |
Ahmir B Mohd Nazri, Ahmir |
author_facet |
Ahmir B Mohd Nazri, Ahmir |
author_sort |
Ahmir B Mohd Nazri, Ahmir |
title |
Analysis Of The Air Distribution Through Ventilation Duct In Block 13 Lecturers’s Office Space |
title_short |
Analysis Of The Air Distribution Through Ventilation Duct In Block 13 Lecturers’s Office Space |
title_full |
Analysis Of The Air Distribution Through Ventilation Duct In Block 13 Lecturers’s Office Space |
title_fullStr |
Analysis Of The Air Distribution Through Ventilation Duct In Block 13 Lecturers’s Office Space |
title_full_unstemmed |
Analysis Of The Air Distribution Through Ventilation Duct In Block 13 Lecturers’s Office Space |
title_sort |
analysis of the air distribution through ventilation duct in block 13 lecturers’s office space |
publisher |
Universiti Teknologi Petronas |
publishDate |
2010 |
url |
http://utpedia.utp.edu.my/1381/1/AHMIR_B_MOHD_NAZRI.pdf http://utpedia.utp.edu.my/1381/ |
_version_ |
1739830769880137728 |
score |
13.222552 |