MONITORING UNDERGROUND CABLE CONDITION UTILIZING THIRD HARMONIC CURRENT

Power failure in a power system caused by unscheduled cable failure may give significant problem to the utility company and to the consumers. This unscheduled cable failure can be overcame by periodically monitor the cable condition. There are many ways to monitor cable condition such as visual insp...

Full description

Saved in:
Bibliographic Details
Main Author: Mohd Yusof, Mohd Asnawi
Format: Final Year Project
Language:English
Published: Universiti Teknologi Petronas 2014
Subjects:
Online Access:http://utpedia.utp.edu.my/13464/1/asnawi.pdf
http://utpedia.utp.edu.my/13464/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-utp-utpedia.13464
record_format eprints
spelling my-utp-utpedia.134642017-01-25T09:38:04Z http://utpedia.utp.edu.my/13464/ MONITORING UNDERGROUND CABLE CONDITION UTILIZING THIRD HARMONIC CURRENT Mohd Yusof, Mohd Asnawi TK Electrical engineering. Electronics Nuclear engineering Power failure in a power system caused by unscheduled cable failure may give significant problem to the utility company and to the consumers. This unscheduled cable failure can be overcame by periodically monitor the cable condition. There are many ways to monitor cable condition such as visual inspection, infrared thermography, ultrasound, insulation resistance and others. Third harmonic in triplen harmonics may also be used to monitor cable condition. Lab experiments have been conducted to investigate the relationship of third harmonic voltage and current passing various cable conditions that specifically affected by their insulation. The objective of this research is to study the applicability of using third harmonic to monitor cable condition. Preliminary research is done to collect necessity information and vigorous lab with different loads is initiated to achieve the objective. Further discussion is made to come out with a conclusion of the project and recommended steps are listed for future development. The results show a significant existence of third harmonic voltage and current at the phase line and the value at the neutral line is three times from the phase line. Connection of transformer (delta-wye) will only circulate the third harmonic current at delta connection from flowing continuously into the wye connection and the load. The third harmonic flows through a capacitor significantly at a range value of 1uF to 2uF. Universiti Teknologi Petronas 2014-01 Final Year Project NonPeerReviewed application/pdf en http://utpedia.utp.edu.my/13464/1/asnawi.pdf Mohd Yusof, Mohd Asnawi (2014) MONITORING UNDERGROUND CABLE CONDITION UTILIZING THIRD HARMONIC CURRENT. Universiti Teknologi Petronas. (Unpublished)
institution Universiti Teknologi Petronas
building UTP Resource Centre
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Petronas
content_source UTP Electronic and Digitized Intellectual Asset
url_provider http://utpedia.utp.edu.my/
language English
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Mohd Yusof, Mohd Asnawi
MONITORING UNDERGROUND CABLE CONDITION UTILIZING THIRD HARMONIC CURRENT
description Power failure in a power system caused by unscheduled cable failure may give significant problem to the utility company and to the consumers. This unscheduled cable failure can be overcame by periodically monitor the cable condition. There are many ways to monitor cable condition such as visual inspection, infrared thermography, ultrasound, insulation resistance and others. Third harmonic in triplen harmonics may also be used to monitor cable condition. Lab experiments have been conducted to investigate the relationship of third harmonic voltage and current passing various cable conditions that specifically affected by their insulation. The objective of this research is to study the applicability of using third harmonic to monitor cable condition. Preliminary research is done to collect necessity information and vigorous lab with different loads is initiated to achieve the objective. Further discussion is made to come out with a conclusion of the project and recommended steps are listed for future development. The results show a significant existence of third harmonic voltage and current at the phase line and the value at the neutral line is three times from the phase line. Connection of transformer (delta-wye) will only circulate the third harmonic current at delta connection from flowing continuously into the wye connection and the load. The third harmonic flows through a capacitor significantly at a range value of 1uF to 2uF.
format Final Year Project
author Mohd Yusof, Mohd Asnawi
author_facet Mohd Yusof, Mohd Asnawi
author_sort Mohd Yusof, Mohd Asnawi
title MONITORING UNDERGROUND CABLE CONDITION UTILIZING THIRD HARMONIC CURRENT
title_short MONITORING UNDERGROUND CABLE CONDITION UTILIZING THIRD HARMONIC CURRENT
title_full MONITORING UNDERGROUND CABLE CONDITION UTILIZING THIRD HARMONIC CURRENT
title_fullStr MONITORING UNDERGROUND CABLE CONDITION UTILIZING THIRD HARMONIC CURRENT
title_full_unstemmed MONITORING UNDERGROUND CABLE CONDITION UTILIZING THIRD HARMONIC CURRENT
title_sort monitoring underground cable condition utilizing third harmonic current
publisher Universiti Teknologi Petronas
publishDate 2014
url http://utpedia.utp.edu.my/13464/1/asnawi.pdf
http://utpedia.utp.edu.my/13464/
_version_ 1739831899657863168
score 13.211869