Improvement To Shunt Contactors for External Floating Roof Tank Lightning Protection System
This project is to prevent the formation of electrical spark during a lightning strike; this is one of the main causes of rim fire on an external floating roof tank. During my internship at Petronas Penapisan Terengganu Sdn. Bhd. (PPTSB), the engineers are trying to prevent more fire incident from o...
Saved in:
Main Author: | |
---|---|
Format: | Final Year Project |
Language: | English |
Published: |
Universiti Teknologi Petronas
2010
|
Subjects: | |
Online Access: | http://utpedia.utp.edu.my/1109/1/Mohd_Yusri_B._Mohd_Yusoff.pdf http://utpedia.utp.edu.my/1109/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my-utp-utpedia.1109 |
---|---|
record_format |
eprints |
spelling |
my-utp-utpedia.11092017-01-25T09:43:31Z http://utpedia.utp.edu.my/1109/ Improvement To Shunt Contactors for External Floating Roof Tank Lightning Protection System Mohd Yusri B. Mohd Yusoff, Mohd Yusri TK Electrical engineering. Electronics Nuclear engineering This project is to prevent the formation of electrical spark during a lightning strike; this is one of the main causes of rim fire on an external floating roof tank. During my internship at Petronas Penapisan Terengganu Sdn. Bhd. (PPTSB), the engineers are trying to prevent more fire incident from occurring on their floating roof tank that are used to store highly volatile petroleum products. The sparking is caused by the gap between the contact shunt and the tank wall. When the tank roof a stroked by lightning the shunt should provide a low resistance path to conduct the high current, but if a gap exist between them spark will be produce. To make things worse the current design of floating roof tank has place this contact at a location that has high flammable gas concentration. In this project, I will attempt to improve the design on the current shunt contactors so that no gap will be formed between it and the tank wall. At the end of this project, I will fabricate a scaled to show how it will work. I will test it against a conductive wall (metal or steel) using high voltage source to see whether any sparking occurs. Universiti Teknologi Petronas 2010 Final Year Project NonPeerReviewed application/pdf en http://utpedia.utp.edu.my/1109/1/Mohd_Yusri_B._Mohd_Yusoff.pdf Mohd Yusri B. Mohd Yusoff, Mohd Yusri (2010) Improvement To Shunt Contactors for External Floating Roof Tank Lightning Protection System. Universiti Teknologi Petronas, Sri Iskandar,Tronoh,Perak. (Unpublished) |
institution |
Universiti Teknologi Petronas |
building |
UTP Resource Centre |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Petronas |
content_source |
UTP Electronic and Digitized Intellectual Asset |
url_provider |
http://utpedia.utp.edu.my/ |
language |
English |
topic |
TK Electrical engineering. Electronics Nuclear engineering |
spellingShingle |
TK Electrical engineering. Electronics Nuclear engineering Mohd Yusri B. Mohd Yusoff, Mohd Yusri Improvement To Shunt Contactors for External Floating Roof Tank Lightning Protection System |
description |
This project is to prevent the formation of electrical spark during a lightning strike; this is one of the main causes of rim fire on an external floating roof tank. During my internship at Petronas Penapisan Terengganu Sdn. Bhd. (PPTSB), the engineers are trying to prevent more fire incident from occurring on their floating roof tank that are used to store highly volatile petroleum products. The sparking is caused by the gap between the contact shunt and the tank wall. When the tank roof a stroked by lightning the shunt should provide a low resistance path to conduct the high current, but if a gap exist between them spark will be produce. To make things worse the current design of floating roof tank has place this contact at a location that has high flammable gas concentration. In this project, I will attempt to improve the design on the current shunt contactors so that no gap will be formed between it and the tank wall. At the end of this project, I will fabricate a scaled to show how it will work. I will test it against a conductive wall (metal or steel) using high voltage source to see whether any sparking occurs. |
format |
Final Year Project |
author |
Mohd Yusri B. Mohd Yusoff, Mohd Yusri |
author_facet |
Mohd Yusri B. Mohd Yusoff, Mohd Yusri |
author_sort |
Mohd Yusri B. Mohd Yusoff, Mohd Yusri |
title |
Improvement To Shunt Contactors for External Floating Roof Tank Lightning Protection System |
title_short |
Improvement To Shunt Contactors for External Floating Roof Tank Lightning Protection System |
title_full |
Improvement To Shunt Contactors for External Floating Roof Tank Lightning Protection System |
title_fullStr |
Improvement To Shunt Contactors for External Floating Roof Tank Lightning Protection System |
title_full_unstemmed |
Improvement To Shunt Contactors for External Floating Roof Tank Lightning Protection System |
title_sort |
improvement to shunt contactors for external floating roof tank lightning protection system |
publisher |
Universiti Teknologi Petronas |
publishDate |
2010 |
url |
http://utpedia.utp.edu.my/1109/1/Mohd_Yusri_B._Mohd_Yusoff.pdf http://utpedia.utp.edu.my/1109/ |
_version_ |
1739830735323267072 |
score |
13.211869 |