THE STUDY AND EVALUATION OF OUTPUT PARAMETERS IN SRBC

In era of technology, rapid advancement of low-loss converter design has become a major challenge to designers. Synchronous Rectifier Buck Converter (SRBC) is one of them. It is perceived that the development of low power converters in future must have the capability to operate in megahertz switc...

全面介紹

Saved in:
書目詳細資料
主要作者: AHMAD, NUR FATIN 'IZZATI
格式: Final Year Project
語言:English
出版: Universiti Teknologi PETRONAS 2011
主題:
在線閱讀:http://utpedia.utp.edu.my/10353/1/2011%20-%20The%20Study%20and%20Evaluation%20of%20Putput%20Parameters%20in%20SRBC.pdf
http://utpedia.utp.edu.my/10353/
標簽: 添加標簽
沒有標簽, 成為第一個標記此記錄!
id my-utp-utpedia.10353
record_format eprints
spelling my-utp-utpedia.103532017-01-25T09:42:43Z http://utpedia.utp.edu.my/10353/ THE STUDY AND EVALUATION OF OUTPUT PARAMETERS IN SRBC AHMAD, NUR FATIN 'IZZATI TK Electrical engineering. Electronics Nuclear engineering In era of technology, rapid advancement of low-loss converter design has become a major challenge to designers. Synchronous Rectifier Buck Converter (SRBC) is one of them. It is perceived that the development of low power converters in future must have the capability to operate in megahertz switching frequency. In this work, the study and evaluation of parameters in SRBC for two conditions: Continuous Conduction Mode (CCM) and Discontinuous Conduction Mode (DCM) will be carried out. This will help in search of the optimized parameter values for both conditions. This project will be based on simulation circuit using PSPICE software. The simulation will involve the study of the data sheet, circuit operation and the fundamental of SRBC circuit. Then, the results will be evaluated in terms of its losses, ripple and also body diode conduction. At the end of the project, the comparison between Conventional SRBC with Adaptive Gate Drive (AGD), Compensator and AGD, MOSFET Parallelism and Maximum Power Point Tracking (MPPT) are done to analyze on the performance of the circuit. It is found that the optimized parameter values for CCM are £=15 11H, C=0.625 11F and R=3.5 n while for DCM the value are L=l 11H, C=9.375 f.IF and R=4 n. Comparatively, it is proven that the Conventional SRBC is best when implementing using MPPT controller due to its ability in improving the output voltage and current and also reducing the losses which are voltage ripple, current ripple and body diode conduction. Universiti Teknologi PETRONAS 2011 Final Year Project NonPeerReviewed application/pdf en http://utpedia.utp.edu.my/10353/1/2011%20-%20The%20Study%20and%20Evaluation%20of%20Putput%20Parameters%20in%20SRBC.pdf AHMAD, NUR FATIN 'IZZATI (2011) THE STUDY AND EVALUATION OF OUTPUT PARAMETERS IN SRBC. Universiti Teknologi PETRONAS. (Unpublished)
institution Universiti Teknologi Petronas
building UTP Resource Centre
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Petronas
content_source UTP Electronic and Digitized Intellectual Asset
url_provider http://utpedia.utp.edu.my/
language English
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
AHMAD, NUR FATIN 'IZZATI
THE STUDY AND EVALUATION OF OUTPUT PARAMETERS IN SRBC
description In era of technology, rapid advancement of low-loss converter design has become a major challenge to designers. Synchronous Rectifier Buck Converter (SRBC) is one of them. It is perceived that the development of low power converters in future must have the capability to operate in megahertz switching frequency. In this work, the study and evaluation of parameters in SRBC for two conditions: Continuous Conduction Mode (CCM) and Discontinuous Conduction Mode (DCM) will be carried out. This will help in search of the optimized parameter values for both conditions. This project will be based on simulation circuit using PSPICE software. The simulation will involve the study of the data sheet, circuit operation and the fundamental of SRBC circuit. Then, the results will be evaluated in terms of its losses, ripple and also body diode conduction. At the end of the project, the comparison between Conventional SRBC with Adaptive Gate Drive (AGD), Compensator and AGD, MOSFET Parallelism and Maximum Power Point Tracking (MPPT) are done to analyze on the performance of the circuit. It is found that the optimized parameter values for CCM are £=15 11H, C=0.625 11F and R=3.5 n while for DCM the value are L=l 11H, C=9.375 f.IF and R=4 n. Comparatively, it is proven that the Conventional SRBC is best when implementing using MPPT controller due to its ability in improving the output voltage and current and also reducing the losses which are voltage ripple, current ripple and body diode conduction.
format Final Year Project
author AHMAD, NUR FATIN 'IZZATI
author_facet AHMAD, NUR FATIN 'IZZATI
author_sort AHMAD, NUR FATIN 'IZZATI
title THE STUDY AND EVALUATION OF OUTPUT PARAMETERS IN SRBC
title_short THE STUDY AND EVALUATION OF OUTPUT PARAMETERS IN SRBC
title_full THE STUDY AND EVALUATION OF OUTPUT PARAMETERS IN SRBC
title_fullStr THE STUDY AND EVALUATION OF OUTPUT PARAMETERS IN SRBC
title_full_unstemmed THE STUDY AND EVALUATION OF OUTPUT PARAMETERS IN SRBC
title_sort study and evaluation of output parameters in srbc
publisher Universiti Teknologi PETRONAS
publishDate 2011
url http://utpedia.utp.edu.my/10353/1/2011%20-%20The%20Study%20and%20Evaluation%20of%20Putput%20Parameters%20in%20SRBC.pdf
http://utpedia.utp.edu.my/10353/
_version_ 1739831792854106112
score 13.251813