Fouling Mitigation Suite: GUI Development in Excel

The objective of this project is to develop a fouling prediction model in crude preheat train (CPT) in refinery. Heat exchanger is a very important device of equipment that is commonly used in industry such as petrochemical, processing and refinery plant. Heat exchanger is used to transfer heat f...

Full description

Saved in:
Bibliographic Details
Main Author: Mohamad Zin, Hafiza Bismilhuda
Format: Final Year Project
Language:English
Published: Universiti Teknologi PETRONAS 2010
Subjects:
Online Access:http://utpedia.utp.edu.my/10057/1/2010%20-%20Fouling%20Mitigation%20Suite%20GUI%20Development%20in%20Excel.pdf
http://utpedia.utp.edu.my/10057/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-utp-utpedia.10057
record_format eprints
spelling my-utp-utpedia.100572013-10-29T10:51:47Z http://utpedia.utp.edu.my/10057/ Fouling Mitigation Suite: GUI Development in Excel Mohamad Zin, Hafiza Bismilhuda TP Chemical technology The objective of this project is to develop a fouling prediction model in crude preheat train (CPT) in refinery. Heat exchanger is a very important device of equipment that is commonly used in industry such as petrochemical, processing and refinery plant. Heat exchanger is used to transfer heat from a liquid on one side of a barrier to a fluid on the other side without bringing the fluid into direct contact. The crude preheat train (CPT) in a petroleum refinery consist consists of a setof large heat exchangers which recovers the waste heat from product streams to preheat the crude oil. The accumulation of unwanted deposits on heat transfer equipment results in reduced efficiency of heat recovery. This phenomenon is called heat exchanger fouling. In addition to this project, the research will be associated with the development of user interface (GUI) for reading and writing data into the model. Fouling model is developed based on the actual data taking from PETRONAS Penapisan Melaka (PPMSB). The model will predict the fouling resistance, Rfonce the input which are crude andproduct properties, crude and product mass flowrate, crude and product inlet temperature and time. Rf will be used in the simulation of heat exchanger using PETROSIM for the calculation of actual outlet temperature of crude and product. All the product and crude properties is generated in the PETROSIM before it was exported to the Microsoft Excel. The results which are the outlet temperature of the crude and product obtained in the model will be compared with the actual data from refinery plantafterthe reconsilation, to justifythe accurateness of the model. Universiti Teknologi PETRONAS 2010-07 Final Year Project NonPeerReviewed application/pdf en http://utpedia.utp.edu.my/10057/1/2010%20-%20Fouling%20Mitigation%20Suite%20GUI%20Development%20in%20Excel.pdf Mohamad Zin, Hafiza Bismilhuda (2010) Fouling Mitigation Suite: GUI Development in Excel. Universiti Teknologi PETRONAS. (Unpublished)
institution Universiti Teknologi Petronas
building UTP Resource Centre
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Petronas
content_source UTP Electronic and Digitized Intellectual Asset
url_provider http://utpedia.utp.edu.my/
language English
topic TP Chemical technology
spellingShingle TP Chemical technology
Mohamad Zin, Hafiza Bismilhuda
Fouling Mitigation Suite: GUI Development in Excel
description The objective of this project is to develop a fouling prediction model in crude preheat train (CPT) in refinery. Heat exchanger is a very important device of equipment that is commonly used in industry such as petrochemical, processing and refinery plant. Heat exchanger is used to transfer heat from a liquid on one side of a barrier to a fluid on the other side without bringing the fluid into direct contact. The crude preheat train (CPT) in a petroleum refinery consist consists of a setof large heat exchangers which recovers the waste heat from product streams to preheat the crude oil. The accumulation of unwanted deposits on heat transfer equipment results in reduced efficiency of heat recovery. This phenomenon is called heat exchanger fouling. In addition to this project, the research will be associated with the development of user interface (GUI) for reading and writing data into the model. Fouling model is developed based on the actual data taking from PETRONAS Penapisan Melaka (PPMSB). The model will predict the fouling resistance, Rfonce the input which are crude andproduct properties, crude and product mass flowrate, crude and product inlet temperature and time. Rf will be used in the simulation of heat exchanger using PETROSIM for the calculation of actual outlet temperature of crude and product. All the product and crude properties is generated in the PETROSIM before it was exported to the Microsoft Excel. The results which are the outlet temperature of the crude and product obtained in the model will be compared with the actual data from refinery plantafterthe reconsilation, to justifythe accurateness of the model.
format Final Year Project
author Mohamad Zin, Hafiza Bismilhuda
author_facet Mohamad Zin, Hafiza Bismilhuda
author_sort Mohamad Zin, Hafiza Bismilhuda
title Fouling Mitigation Suite: GUI Development in Excel
title_short Fouling Mitigation Suite: GUI Development in Excel
title_full Fouling Mitigation Suite: GUI Development in Excel
title_fullStr Fouling Mitigation Suite: GUI Development in Excel
title_full_unstemmed Fouling Mitigation Suite: GUI Development in Excel
title_sort fouling mitigation suite: gui development in excel
publisher Universiti Teknologi PETRONAS
publishDate 2010
url http://utpedia.utp.edu.my/10057/1/2010%20-%20Fouling%20Mitigation%20Suite%20GUI%20Development%20in%20Excel.pdf
http://utpedia.utp.edu.my/10057/
_version_ 1739831753916284928
score 13.211869