Numerical study of hybrid through plate connections to CFST columns

The use of concrete-filled steel tube (CFST) columns is highly encouraged nowadays in modern multistory structures. The major reason is the extensive resistance offered by the hollow steel column to high compression. Nevertheless, further studies and data are desirable to exhaustively characteri...

Full description

Saved in:
Bibliographic Details
Main Authors: Twizere, Moussa, Taşkin, Kıvanc
Format: Article
Language:English
Published: Penerbit Universiti Kebangsaan Malaysia 2022
Online Access:http://journalarticle.ukm.my/20329/1/09.pdf
http://journalarticle.ukm.my/20329/
https://www.ukm.my/jkukm/volume-3404-2022/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-ukm.journal.20329
record_format eprints
spelling my-ukm.journal.203292022-11-02T01:22:31Z http://journalarticle.ukm.my/20329/ Numerical study of hybrid through plate connections to CFST columns Twizere, Moussa Taşkin, Kıvanc The use of concrete-filled steel tube (CFST) columns is highly encouraged nowadays in modern multistory structures. The major reason is the extensive resistance offered by the hollow steel column to high compression. Nevertheless, further studies and data are desirable to exhaustively characterize these members and their connections to other members, such as beams. This paper investigated the behavior of concrete-filled columns connected to I-beams by through plates. Three simple types of plate connections (easy to assemble and construct) were proposed and evaluated. The behavior of these connections was examined under static loading by using advanced finite element based software (ABAQUS). The modeling techniques used in this study were validated by comparing the numerical results of a through plate connection model with the results of two relevant experimental studies. The proposed connections were classified as semi-rigid connections according to Eurocode-3. These connections were able to move the plastic hinge away from the column panel zone. The maximum plastic rotations of all connection types were greater than 40 mrad. The failure mode, and moment-rotation curves of the concrete-filled column to steel beam connections were discussed based on numerical results. The influence of through plate material and through plate thickness were evaluated via a parametrical study. Penerbit Universiti Kebangsaan Malaysia 2022 Article PeerReviewed application/pdf en http://journalarticle.ukm.my/20329/1/09.pdf Twizere, Moussa and Taşkin, Kıvanc (2022) Numerical study of hybrid through plate connections to CFST columns. Jurnal Kejuruteraan, 34 (4). pp. 605-615. ISSN 0128-0198 https://www.ukm.my/jkukm/volume-3404-2022/
institution Universiti Kebangsaan Malaysia
building Tun Sri Lanang Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Kebangsaan Malaysia
content_source UKM Journal Article Repository
url_provider http://journalarticle.ukm.my/
language English
description The use of concrete-filled steel tube (CFST) columns is highly encouraged nowadays in modern multistory structures. The major reason is the extensive resistance offered by the hollow steel column to high compression. Nevertheless, further studies and data are desirable to exhaustively characterize these members and their connections to other members, such as beams. This paper investigated the behavior of concrete-filled columns connected to I-beams by through plates. Three simple types of plate connections (easy to assemble and construct) were proposed and evaluated. The behavior of these connections was examined under static loading by using advanced finite element based software (ABAQUS). The modeling techniques used in this study were validated by comparing the numerical results of a through plate connection model with the results of two relevant experimental studies. The proposed connections were classified as semi-rigid connections according to Eurocode-3. These connections were able to move the plastic hinge away from the column panel zone. The maximum plastic rotations of all connection types were greater than 40 mrad. The failure mode, and moment-rotation curves of the concrete-filled column to steel beam connections were discussed based on numerical results. The influence of through plate material and through plate thickness were evaluated via a parametrical study.
format Article
author Twizere, Moussa
Taşkin, Kıvanc
spellingShingle Twizere, Moussa
Taşkin, Kıvanc
Numerical study of hybrid through plate connections to CFST columns
author_facet Twizere, Moussa
Taşkin, Kıvanc
author_sort Twizere, Moussa
title Numerical study of hybrid through plate connections to CFST columns
title_short Numerical study of hybrid through plate connections to CFST columns
title_full Numerical study of hybrid through plate connections to CFST columns
title_fullStr Numerical study of hybrid through plate connections to CFST columns
title_full_unstemmed Numerical study of hybrid through plate connections to CFST columns
title_sort numerical study of hybrid through plate connections to cfst columns
publisher Penerbit Universiti Kebangsaan Malaysia
publishDate 2022
url http://journalarticle.ukm.my/20329/1/09.pdf
http://journalarticle.ukm.my/20329/
https://www.ukm.my/jkukm/volume-3404-2022/
_version_ 1748704125364731904
score 13.211869