Review of X-ray phase contrast imaging techniques and propagation based imaging using a Benchtop Microfocal Source
Currently, the basis for standard clinical X-ray radiography is absorption, tracking attenuation of radiation when X-ray beams pass through a particular part of the body. The fundamental interaction processes are dependent on variations in the atomic number and density of the target medium; consequ...
Saved in:
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
penerbit ukm
2007
|
Online Access: | http://journalarticle.ukm.my/1045/1/jurnal66.pdf http://journalarticle.ukm.my/1045/ http://www.fskb.ukm.my/fskbold/jurnal |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my-ukm.journal.1045 |
---|---|
record_format |
eprints |
spelling |
my-ukm.journal.10452016-12-14T06:28:40Z http://journalarticle.ukm.my/1045/ Review of X-ray phase contrast imaging techniques and propagation based imaging using a Benchtop Microfocal Source Bradley, David Gondogdu, Ozcan Jenneson, Paul Nirgianaki, Eleftheria Elna Herawati Che Ismail, Currently, the basis for standard clinical X-ray radiography is absorption, tracking attenuation of radiation when X-ray beams pass through a particular part of the body. The fundamental interaction processes are dependent on variations in the atomic number and density of the target medium; consequentially radiographic contrast can be poor, particularly in regard to soft tissue imaging. Over the past several years considerable interest has been paid to utilising phase properties of the X-ray field to enhance radiographic Jurnal Sains Kesihatan Malaysia 5 (1) 2007: 1-162 contrast in challenging circumstances, particularly with respect to soft-tissue imaging. Surrey is among an increasing number of institutes in which a programme of investigation of phase contrast X-ray imaging has been established. We briefly review some basic ideas in X-ray phase contrast imaging and then examine the radiographic contrast enhancement that can be obtained, use being made of the method of free-space propagation and investigating a number of test objects, including biological samples. The equipment used at Surrey is relatively simple, comprising of bench-top X-ray tubes with focal spot sizes from a few microns up to 100 microns and a position sensitive 12 bit CCD detector. penerbit ukm 2007 Article PeerReviewed application/pdf en http://journalarticle.ukm.my/1045/1/jurnal66.pdf Bradley, David and Gondogdu, Ozcan and Jenneson, Paul and Nirgianaki, Eleftheria and Elna Herawati Che Ismail, (2007) Review of X-ray phase contrast imaging techniques and propagation based imaging using a Benchtop Microfocal Source. Jurnal Sains Kesihatan Malaysia, 5 (1). pp. 1-16. ISSN 1675-8161 http://www.fskb.ukm.my/fskbold/jurnal |
institution |
Universiti Kebangsaan Malaysia |
building |
Perpustakaan Tun Sri Lanang Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Kebangsaan Malaysia |
content_source |
UKM Journal Article Repository |
url_provider |
http://journalarticle.ukm.my/ |
language |
English |
description |
Currently, the basis for standard clinical X-ray radiography is absorption, tracking attenuation of radiation when X-ray beams pass through a particular
part of the body. The fundamental interaction processes are dependent on variations in the atomic number and density of the target medium; consequentially radiographic contrast can be poor, particularly in regard to soft tissue imaging. Over the past several years considerable interest has been
paid to utilising phase properties of the X-ray field to enhance radiographic Jurnal Sains Kesihatan Malaysia 5 (1) 2007: 1-162 contrast in challenging circumstances, particularly with respect to soft-tissue imaging. Surrey is among an increasing number of institutes in which a
programme of investigation of phase contrast X-ray imaging has been established. We briefly review some basic ideas in X-ray phase contrast imaging and then examine the radiographic contrast enhancement that can be obtained,
use being made of the method of free-space propagation and investigating a number of test objects, including biological samples. The equipment used at Surrey is relatively simple, comprising of bench-top X-ray tubes with focal spot sizes from a few microns up to 100 microns and a position sensitive 12 bit CCD detector. |
format |
Article |
author |
Bradley, David Gondogdu, Ozcan Jenneson, Paul Nirgianaki, Eleftheria Elna Herawati Che Ismail, |
spellingShingle |
Bradley, David Gondogdu, Ozcan Jenneson, Paul Nirgianaki, Eleftheria Elna Herawati Che Ismail, Review of X-ray phase contrast imaging techniques and propagation based imaging using a Benchtop Microfocal Source |
author_facet |
Bradley, David Gondogdu, Ozcan Jenneson, Paul Nirgianaki, Eleftheria Elna Herawati Che Ismail, |
author_sort |
Bradley, David |
title |
Review of X-ray phase contrast imaging techniques and propagation based imaging using a Benchtop Microfocal Source |
title_short |
Review of X-ray phase contrast imaging techniques and propagation based imaging using a Benchtop Microfocal Source |
title_full |
Review of X-ray phase contrast imaging techniques and propagation based imaging using a Benchtop Microfocal Source |
title_fullStr |
Review of X-ray phase contrast imaging techniques and propagation based imaging using a Benchtop Microfocal Source |
title_full_unstemmed |
Review of X-ray phase contrast imaging techniques and propagation based imaging using a Benchtop Microfocal Source |
title_sort |
review of x-ray phase contrast imaging techniques and propagation based imaging using a benchtop microfocal source |
publisher |
penerbit ukm |
publishDate |
2007 |
url |
http://journalarticle.ukm.my/1045/1/jurnal66.pdf http://journalarticle.ukm.my/1045/ http://www.fskb.ukm.my/fskbold/jurnal |
_version_ |
1643734877591306240 |
score |
13.211869 |