Search Results - (( pressure distribution detection algorithm ) OR ( parameters variation acs algorithm ))

Refine Results
  1. 1

    Predictive Maximum Power Point Tracking for Proton Exchange Membrane Fuel Cell System by Jye Yun, Fam

    Published 2025
    “…However, fluctuations in the internal parameters of PEMFC can cause variations in power output. …”
    Get full text
    Get full text
    Get full text
    Get full text
    Thesis
  2. 2

    Development of intelligent leak detection system based on artificial pressure transient signal using integrated Kurtosis-based Algorithm for Z-filter Technique (I-Kaz) by Hanafi, M. Yusop, M. F., Ghazali, Mohd Fadhlan, Mohd Yusof, Wan Sofian, Wan Hamat

    Published 2017
    “…In recent studies, the analysis of pressure transient signal can be seen as an accurate and low-cost method for the leak and feature detection in water distribution system. …”
    Get full text
    Get full text
    Get full text
    Article
  3. 3

    Development of Intelligent Leak Detection System Based on Artificial Pressure Transient Signal Using Integrated Kurtosis-Based Algorithm for Z-Filter Technique (I-Kaz) / Hanafi.M.Y... by M.Yusop, Hanafi, Ghazali, M.F., M.Yusof, M.F., W.Hamat, W.S.

    Published 2017
    “…In recent studies, the analysis of pressure transient signal can be seen as an accurate and low-cost method for the leak and feature detection in water distribution system. …”
    Get full text
    Get full text
    Article
  4. 4

    Detection of leak size and its location in a water distribution system by using K-NN / Nasereddin Ibrahim Sherksi by Sherksi, Nasereddin Ibrahim

    Published 2020
    “…The successfully achieved four set objectives inclusive of (1) a new classification model to detect water leakage, (2) analysis of the effects of leakage size on the variables within a WDS, i.e. flow, pressure, pipe volume, velocity and water demand, (3) locating and specifying the leakage size in the WDS, and (4) evaluate the performance of the designed K-NN algorithm for accurate leak detection. …”
    Get full text
    Get full text
    Thesis
  5. 5

    Image processing based foot plantar pressure distribution analysis and modeling by Sabry, Ali Hussein, Wan Hasan, Wan Zuha, Mohtar, Mohd Nazim, Raja Ahmad, Raja Mohd Kamil, Ramli, Hafiz Rashidi, Ang, S. P., Abdul Hamid, Zainidi

    Published 2020
    “…Although many equipments and techniques are available for plantar pressure analysis to study foot pressure distributions, there is still a need for mathematical modelling references to compare the acquired measurements. …”
    Get full text
    Get full text
    Get full text
    Article
  6. 6
  7. 7
  8. 8

    Sensor-less vector control using adaptive observer scheme for controlling the performance of the induction motor / Mazhar Hussain Abbasi by Mazhar, Hussain Abbasi

    Published 2013
    “…Internal parameters are used, for example, feed-forward compensator of current controller and parameters of observer model in sensor less position. …”
    Get full text
    Get full text
    Thesis
  9. 9
  10. 10

    Speed Performance Improvement Of Three-Phase Induction Motor Drives Using Adaptive Sliding Mode Controller by Mohd Aziri, Muhammad Hasif

    Published 2020
    “…The PI or PID controllers are tuned to improve speed control issues of AC induction motor due to load variations and changes in parameters. …”
    Get full text
    Get full text
    Get full text
    Get full text
    Thesis
  11. 11

    Transient analysis for leak signature identification based on Hilbert Huang transform and integrated kurtosis algorithm for z-notch filter technique by Muhammad Hanafi, Yusop

    Published 2018
    “…In a recent study, the analysis of pressure transient signals could be seen as an accurate and low-cost method for leak and feature detection in water distribution systems. …”
    Get full text
    Get full text
    Thesis
  12. 12
  13. 13

    Fault Detection Relevant Modeling of an Industrial Gas Turbine based on Neuro-Fuzzy Approach by Alemu Lemma, Tamiru, Mohd Hashim, Fakhruldin, Rangkuti, Chalillullah

    Published 2010
    “…A reference model is compared with the real-time data to detect bias or incipient faults. A neuro-fuzzy (NF) reference model has been developed for the compressor discharge pressure and output electricity of an industrial gas turbine. …”
    Get full text
    Conference or Workshop Item
  14. 14

    DC-based PV-powered home energy system by Sabry, Ahmad H.

    Published 2017
    “…The controller algorithm requires also the variation range of the geographical weather parameters (irradiance and temperature) to specify the MPP which is equivalent to that operating voltage at minimum weather parameters. …”
    Get full text
    Get full text
    Thesis
  15. 15

    Host Based Intrusion Detection and Prevention Model Against DDoS Attack in Cloud Computing by Jaber, Aws Naser, Mohamad Fadli, Zolkipli, Shakir, Hasan Awni

    Published 2018
    “…The main focus of the present research is the design of a model that prevents distributed denial-of-service attacks based on host-based intrusion detection protection systems over hypervisor environments. …”
    Get full text
    Get full text
    Get full text
    Book Chapter
  16. 16
  17. 17
  18. 18

    Pipe Leak Diagnostic Using High Frequency Piezoelectric Pressure Sensor And Automatic Selection Of Intrinsic Mode Function by Hanafi, M. Yusop, M. F., Ghazali, M. F. M., Yusof, Remli, M. A. Pi, M. H., Kamarulzaman

    Published 2017
    “…In a recent study, the analysis of pressure transient signals could be seen as an accurate and low-cost method for leak and feature detection in water distribution systems. …”
    Get full text
    Get full text
    Get full text
    Conference or Workshop Item
  19. 19

    Neuro-Fuzzy and Particle Swarm Optimization based Model for the Steam and Cooling sections of a Cogeneration and Cooling Plant by Alemu Lemma, Tamiru, Rangkuti, Chalillullah, Mohd Hashim, Fakhruldin

    Published 2009
    “…Varying the probability in reading the percentage value of t-distribution for fixed degrees of freedom, a test is also performed on the capacity of the models for fault detection. …”
    Get full text
    Conference or Workshop Item
  20. 20

    Design and real time implementation of single phase boost power factor correction converter by Bouafass, A., Rahmani, L., Mekhilef, Saad

    Published 2015
    “…The experimental results proved that the proposed controller enhanced the performance of the converter under different parameters variations. (C) 2014 ISA. Published by Elsevier Ltd. …”
    Get full text
    Get full text
    Get full text
    Article