Removal of Iron from Groundwater by Filtration through Carbonaceous Shale

The project covers a study on the topic entitled "Removal of Iron from Groundwater by Filtration through Carbonaceous Shale". Generally speaking, Iron is commonly present in groundwater worldwide. The presence of iron in groundwater is not harmful to human health, however it is undesira...

Full description

Saved in:
Bibliographic Details
Main Author: Abdul Rahman, Abdul Fatah
Format: Final Year Project
Language:en
Published: Universiti Teknologi PETRONAS 2008
Subjects:
Online Access:http://utpedia.utp.edu.my/id/eprint/10000/1/2008%20Bachelor%20-%20Removal%20Of%20Iron%20From%20Groundwater%20By%20Filtration%20Through%20Carbonaceous%20Shale.pdf
http://utpedia.utp.edu.my/id/eprint/10000/
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1833329129518268416
author Abdul Rahman, Abdul Fatah
author_facet Abdul Rahman, Abdul Fatah
author_sort Abdul Rahman, Abdul Fatah
building UTP Resource Centre
collection Institutional Repository
content_provider Universiti Teknologi Petronas
content_source UTP Electronic and Digitized Intellectual Asset
continent Asia
country Malaysia
description The project covers a study on the topic entitled "Removal of Iron from Groundwater by Filtration through Carbonaceous Shale". Generally speaking, Iron is commonly present in groundwater worldwide. The presence of iron in groundwater is not harmful to human health, however it is undesirable because of the associated aesthetic and operational problem, namely: bad taste, discoloration, stains on laundry and plumbing system and after-growth in the distribution system. Iron present in soluble ferrous form in groundwater oxidizes into insoluble ferric iron when exposed to the atmosphere. Iron removal from groundwater is, therefore, a major concern for water supply companies using groundwater. The objective of this study is to determine the effectiveness of carbonaceous shale in removing iron from groundwater by adsorption-oxidation mechanism and also the backwashing system for the filter. The scope of work consists of literature review, experimental design, laboratory set up, experiments and results analysis. The methods and procedures to achieve the objectives involve analyses of chemical parameters of groundwater used in the experiments including the properties of carbonaceous shale and also filtration performance of carbonaceous shale. Laboratoryscale colnnm experiments were conducted using 31 mm diameter acrylic column pipes with 1.0 m depth of 1.0 mm mean size and having 70 em depth of filter media. The filtration performance of the carbonaceous shale was compare with the sand that works like a 'benchmark' since it is been widely used in the conventional method for iron removal. Both filtration media that been used act as adsorbent of ferrous iron in filtration column. Results from the experiment shows that the concentration of total iron in the groundwater used in the experiment is 2.36 mg/L Fe and that the performance of carbonaceous shale filter is better than sand filter in the iron removal. Iron concentration in the effluent of carbonaceous shale filter is below standard for drinking water which is 0.3 mg/L.
format Final Year Project
id oai:utpedia.utp.edu.my:10000
institution Universiti Teknologi Petronas
language en
publishDate 2008
publisher Universiti Teknologi PETRONAS
record_format eprints
spelling oai:utpedia.utp.edu.my:100002017-01-25T09:45:09Z http://utpedia.utp.edu.my/id/eprint/10000/ Removal of Iron from Groundwater by Filtration through Carbonaceous Shale Abdul Rahman, Abdul Fatah TA Engineering (General). Civil engineering (General) The project covers a study on the topic entitled "Removal of Iron from Groundwater by Filtration through Carbonaceous Shale". Generally speaking, Iron is commonly present in groundwater worldwide. The presence of iron in groundwater is not harmful to human health, however it is undesirable because of the associated aesthetic and operational problem, namely: bad taste, discoloration, stains on laundry and plumbing system and after-growth in the distribution system. Iron present in soluble ferrous form in groundwater oxidizes into insoluble ferric iron when exposed to the atmosphere. Iron removal from groundwater is, therefore, a major concern for water supply companies using groundwater. The objective of this study is to determine the effectiveness of carbonaceous shale in removing iron from groundwater by adsorption-oxidation mechanism and also the backwashing system for the filter. The scope of work consists of literature review, experimental design, laboratory set up, experiments and results analysis. The methods and procedures to achieve the objectives involve analyses of chemical parameters of groundwater used in the experiments including the properties of carbonaceous shale and also filtration performance of carbonaceous shale. Laboratoryscale colnnm experiments were conducted using 31 mm diameter acrylic column pipes with 1.0 m depth of 1.0 mm mean size and having 70 em depth of filter media. The filtration performance of the carbonaceous shale was compare with the sand that works like a 'benchmark' since it is been widely used in the conventional method for iron removal. Both filtration media that been used act as adsorbent of ferrous iron in filtration column. Results from the experiment shows that the concentration of total iron in the groundwater used in the experiment is 2.36 mg/L Fe and that the performance of carbonaceous shale filter is better than sand filter in the iron removal. Iron concentration in the effluent of carbonaceous shale filter is below standard for drinking water which is 0.3 mg/L. Universiti Teknologi PETRONAS 2008-01 Final Year Project NonPeerReviewed application/pdf en http://utpedia.utp.edu.my/id/eprint/10000/1/2008%20Bachelor%20-%20Removal%20Of%20Iron%20From%20Groundwater%20By%20Filtration%20Through%20Carbonaceous%20Shale.pdf Abdul Rahman, Abdul Fatah (2008) Removal of Iron from Groundwater by Filtration through Carbonaceous Shale. [Final Year Project] (Unpublished)
spellingShingle TA Engineering (General). Civil engineering (General)
Abdul Rahman, Abdul Fatah
Removal of Iron from Groundwater by Filtration through Carbonaceous Shale
title Removal of Iron from Groundwater by Filtration through Carbonaceous Shale
title_full Removal of Iron from Groundwater by Filtration through Carbonaceous Shale
title_fullStr Removal of Iron from Groundwater by Filtration through Carbonaceous Shale
title_full_unstemmed Removal of Iron from Groundwater by Filtration through Carbonaceous Shale
title_short Removal of Iron from Groundwater by Filtration through Carbonaceous Shale
title_sort removal of iron from groundwater by filtration through carbonaceous shale
topic TA Engineering (General). Civil engineering (General)
url http://utpedia.utp.edu.my/id/eprint/10000/1/2008%20Bachelor%20-%20Removal%20Of%20Iron%20From%20Groundwater%20By%20Filtration%20Through%20Carbonaceous%20Shale.pdf
http://utpedia.utp.edu.my/id/eprint/10000/
url_provider http://utpedia.utp.edu.my/