The data distribution system of this project is divided into two types, which are a Two-PC Image Reconstruction System and a Two-PC Velocity Measurement System. Each data distribution system is investigated to see whether the results' refreshing rate of the corresponding measurement can be grea...

Full description

Saved in:
Bibliographic Details
Main Authors: Hj. Abdul Rahim, Ruzairi, Pang, Jon Fea, Chan, Kok San, Leong, Lai Chen, Sulaiman, S., Abdul Manaf, M. S.
Format: Article
Published: ELSEVIER SCIENCE INC, 360 PARK AVE SOUTH, NEW YORK, NY 10010-1710 USA 2007
Subjects:
Online Access:http://eprints.utm.my/8660/
http://dx.doi.org/10.1016/j.isatra.2006.07.001
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1845472050051809280
author Hj. Abdul Rahim, Ruzairi
Pang, Jon Fea
Chan, Kok San
Leong, Lai Chen
Sulaiman, S.
Abdul Manaf, M. S.
author_facet Hj. Abdul Rahim, Ruzairi
Pang, Jon Fea
Chan, Kok San
Leong, Lai Chen
Sulaiman, S.
Abdul Manaf, M. S.
author_sort Hj. Abdul Rahim, Ruzairi
building UTM Library
collection Institutional Repository
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
continent Asia
country Malaysia
description The data distribution system of this project is divided into two types, which are a Two-PC Image Reconstruction System and a Two-PC Velocity Measurement System. Each data distribution system is investigated to see whether the results' refreshing rate of the corresponding measurement can be greater than the rate obtained by using a single computer in the same measurement system for each application. Each system has its own flow control protocol for controlling how data is distributed within the system in order to speed up the data processing time. This can be done if two PCs work in parallel. The challenge of this project is to define the data flow process and critical timing during data packaging, transferring and extracting in between PCs. If a single computer is used as a data processing unit, a longer time is needed to produce a measurement result. This insufficient real-time result will cause problems in a feedback control process when applying the system in industrial plants. To increase the refreshing rate of the measurement result, an investigation on a data distribution system is performed to replace the existing data processing unit.
format Article
id my.utm.eprints-8660
institution Universiti Teknologi Malaysia
publishDate 2007
publisher ELSEVIER SCIENCE INC, 360 PARK AVE SOUTH, NEW YORK, NY 10010-1710 USA
record_format eprints
spelling my.utm.eprints-86602009-07-27T05:01:13Z http://eprints.utm.my/8660/ Infrared tomography : data distribution system and software development for real-time velocity measurement Hj. Abdul Rahim, Ruzairi Pang, Jon Fea Chan, Kok San Leong, Lai Chen Sulaiman, S. Abdul Manaf, M. S. TK Electrical engineering. Electronics Nuclear engineering The data distribution system of this project is divided into two types, which are a Two-PC Image Reconstruction System and a Two-PC Velocity Measurement System. Each data distribution system is investigated to see whether the results' refreshing rate of the corresponding measurement can be greater than the rate obtained by using a single computer in the same measurement system for each application. Each system has its own flow control protocol for controlling how data is distributed within the system in order to speed up the data processing time. This can be done if two PCs work in parallel. The challenge of this project is to define the data flow process and critical timing during data packaging, transferring and extracting in between PCs. If a single computer is used as a data processing unit, a longer time is needed to produce a measurement result. This insufficient real-time result will cause problems in a feedback control process when applying the system in industrial plants. To increase the refreshing rate of the measurement result, an investigation on a data distribution system is performed to replace the existing data processing unit. ELSEVIER SCIENCE INC, 360 PARK AVE SOUTH, NEW YORK, NY 10010-1710 USA 2007 Article PeerReviewed Hj. Abdul Rahim, Ruzairi and Pang, Jon Fea and Chan, Kok San and Leong, Lai Chen and Sulaiman, S. and Abdul Manaf, M. S. (2007) Infrared tomography : data distribution system and software development for real-time velocity measurement. ISA Transactions, 46 (2). pp. 131-145. ISSN 0019-0578 http://dx.doi.org/10.1016/j.isatra.2006.07.001 10.1016/j.isatra.2006.07.001
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Hj. Abdul Rahim, Ruzairi
Pang, Jon Fea
Chan, Kok San
Leong, Lai Chen
Sulaiman, S.
Abdul Manaf, M. S.
Infrared tomography : data distribution system and software development for real-time velocity measurement
title Infrared tomography : data distribution system and software development for real-time velocity measurement
title_full Infrared tomography : data distribution system and software development for real-time velocity measurement
title_fullStr Infrared tomography : data distribution system and software development for real-time velocity measurement
title_full_unstemmed Infrared tomography : data distribution system and software development for real-time velocity measurement
title_short Infrared tomography : data distribution system and software development for real-time velocity measurement
title_sort infrared tomography : data distribution system and software development for real-time velocity measurement
topic TK Electrical engineering. Electronics Nuclear engineering
url http://eprints.utm.my/8660/
http://dx.doi.org/10.1016/j.isatra.2006.07.001
url_provider http://eprints.utm.my/