Determination of noise equivalent quanta of medical screen-films

Noise equivalent quanta (NEQ) of Lanex Regular/T Mat G and Lanex Regular/T Mat L screen-film combinations were determined using modulation transfer function (MTF) and noise power spectrum (NPS) data. To accomplish this, average gamma of the radiograph was computed, the MTF and the NPS data were line...

Full description

Saved in:
Bibliographic Details
Main Authors: Wan Hassan, Wan Muhamad Saridan, Munajat, Yusof, Sahibuddin, Shamsul
Format: Article
Language:en
Published: Penerbit UTM Press 2004
Subjects:
Online Access:http://eprints.utm.my/6733/1/Jur_Teknologi_40C_2004_11-19.pdf
http://eprints.utm.my/6733/
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1845471683015606272
author Wan Hassan, Wan Muhamad Saridan
Munajat, Yusof
Sahibuddin, Shamsul
author_facet Wan Hassan, Wan Muhamad Saridan
Munajat, Yusof
Sahibuddin, Shamsul
author_sort Wan Hassan, Wan Muhamad Saridan
building UTM Library
collection Institutional Repository
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
continent Asia
country Malaysia
description Noise equivalent quanta (NEQ) of Lanex Regular/T Mat G and Lanex Regular/T Mat L screen-film combinations were determined using modulation transfer function (MTF) and noise power spectrum (NPS) data. To accomplish this, average gamma of the radiograph was computed, the MTF and the NPS data were linearly interpolated and these values were used to compute the NEQ by means of a computer program. The computation shows that for spatial frequency 0–0.7 cycles/mm the NEQ of Lanex Regular/T Mat G is slightly lower than that of Lanex Regular/T Mat L, for spatial frequency 0.7–1.5 cycles/mm the NEQ of both are almost the same, and for frequencies greater than 1.5 cycles/mm the NEQ of the former is greater than that of the latter. Relatively, this indicates that low frequency signals show better on Lanex Rregula/T Mat L, but high frequency signals show better on Lanex Regular/T Mat G.
format Article
id my.utm.eprints-6733
institution Universiti Teknologi Malaysia
language en
publishDate 2004
publisher Penerbit UTM Press
record_format eprints
spelling my.utm.eprints-67332017-11-01T04:17:37Z http://eprints.utm.my/6733/ Determination of noise equivalent quanta of medical screen-films Wan Hassan, Wan Muhamad Saridan Munajat, Yusof Sahibuddin, Shamsul QC Physics Noise equivalent quanta (NEQ) of Lanex Regular/T Mat G and Lanex Regular/T Mat L screen-film combinations were determined using modulation transfer function (MTF) and noise power spectrum (NPS) data. To accomplish this, average gamma of the radiograph was computed, the MTF and the NPS data were linearly interpolated and these values were used to compute the NEQ by means of a computer program. The computation shows that for spatial frequency 0–0.7 cycles/mm the NEQ of Lanex Regular/T Mat G is slightly lower than that of Lanex Regular/T Mat L, for spatial frequency 0.7–1.5 cycles/mm the NEQ of both are almost the same, and for frequencies greater than 1.5 cycles/mm the NEQ of the former is greater than that of the latter. Relatively, this indicates that low frequency signals show better on Lanex Rregula/T Mat L, but high frequency signals show better on Lanex Regular/T Mat G. Penerbit UTM Press 2004-06 Article PeerReviewed application/pdf en http://eprints.utm.my/6733/1/Jur_Teknologi_40C_2004_11-19.pdf Wan Hassan, Wan Muhamad Saridan and Munajat, Yusof and Sahibuddin, Shamsul (2004) Determination of noise equivalent quanta of medical screen-films. Jurnal Teknologi (40C). pp. 11-19. ISSN 0127-9696
spellingShingle QC Physics
Wan Hassan, Wan Muhamad Saridan
Munajat, Yusof
Sahibuddin, Shamsul
Determination of noise equivalent quanta of medical screen-films
title Determination of noise equivalent quanta of medical screen-films
title_full Determination of noise equivalent quanta of medical screen-films
title_fullStr Determination of noise equivalent quanta of medical screen-films
title_full_unstemmed Determination of noise equivalent quanta of medical screen-films
title_short Determination of noise equivalent quanta of medical screen-films
title_sort determination of noise equivalent quanta of medical screen-films
topic QC Physics
url http://eprints.utm.my/6733/1/Jur_Teknologi_40C_2004_11-19.pdf
http://eprints.utm.my/6733/
url_provider http://eprints.utm.my/