Calibration Tests For Underwater Acoustic Transponders Using Kalman Filter

Two tests were carried out for the calibration of underwater acoustic transponders using Kalman filter. Both tests used the Long Baseline Acoustic Positioning method. The first test is known as the relative calibration test and uses observables only from underwater acoustic transponders. This test i...

Full description

Saved in:
Bibliographic Details
Main Author: Mahmud, Mohd Razali
Format: Article
Language:en
Published: Fakulti Ukur dan Harta Tanah 1995
Subjects:
Online Access:http://eprints.utm.my/5009/1/calibration.pdf
http://eprints.utm.my/5009/
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1845471269736153088
author Mahmud, Mohd Razali
author_facet Mahmud, Mohd Razali
author_sort Mahmud, Mohd Razali
building UTM Library
collection Institutional Repository
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
continent Asia
country Malaysia
description Two tests were carried out for the calibration of underwater acoustic transponders using Kalman filter. Both tests used the Long Baseline Acoustic Positioning method. The first test is known as the relative calibration test and uses observables only from underwater acoustic transponders. This test is for the adjustment of the shape and scale of the transponder array. It requires at least three coordinates to be fixed. The second test, known as the absolute calibration test, involves the observables from four systems (i.e. DGPS, underwater acoustic system, range-range system and hyperbolic system) integrated together to give geodetic position and orientation to the transponder array. The results of both tests are presented.
format Article
id my.utm.eprints-5009
institution Universiti Teknologi Malaysia
language en
publishDate 1995
publisher Fakulti Ukur dan Harta Tanah
record_format eprints
spelling my.utm.eprints-50092010-06-01T03:22:42Z http://eprints.utm.my/5009/ Calibration Tests For Underwater Acoustic Transponders Using Kalman Filter Mahmud, Mohd Razali TA Engineering (General). Civil engineering (General) Two tests were carried out for the calibration of underwater acoustic transponders using Kalman filter. Both tests used the Long Baseline Acoustic Positioning method. The first test is known as the relative calibration test and uses observables only from underwater acoustic transponders. This test is for the adjustment of the shape and scale of the transponder array. It requires at least three coordinates to be fixed. The second test, known as the absolute calibration test, involves the observables from four systems (i.e. DGPS, underwater acoustic system, range-range system and hyperbolic system) integrated together to give geodetic position and orientation to the transponder array. The results of both tests are presented. Fakulti Ukur dan Harta Tanah 1995-02 Article PeerReviewed application/pdf en http://eprints.utm.my/5009/1/calibration.pdf Mahmud, Mohd Razali (1995) Calibration Tests For Underwater Acoustic Transponders Using Kalman Filter. Buletin Ukur, 6 (1). pp. 39-60. ISSN 0128-4274
spellingShingle TA Engineering (General). Civil engineering (General)
Mahmud, Mohd Razali
Calibration Tests For Underwater Acoustic Transponders Using Kalman Filter
title Calibration Tests For Underwater Acoustic Transponders Using Kalman Filter
title_full Calibration Tests For Underwater Acoustic Transponders Using Kalman Filter
title_fullStr Calibration Tests For Underwater Acoustic Transponders Using Kalman Filter
title_full_unstemmed Calibration Tests For Underwater Acoustic Transponders Using Kalman Filter
title_short Calibration Tests For Underwater Acoustic Transponders Using Kalman Filter
title_sort calibration tests for underwater acoustic transponders using kalman filter
topic TA Engineering (General). Civil engineering (General)
url http://eprints.utm.my/5009/1/calibration.pdf
http://eprints.utm.my/5009/
url_provider http://eprints.utm.my/