Normal stacking mode (NSM) in improving the detection sensitivity of dioxin related compounds using micellar electrokinetic chromatography

Micellar electrokinetic chromatography (MEKC) with diode array detection (DAD) was used to separate two dioxin related compounds viz. 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD) and 2,3,7,8-tetrachlorodibenzo-p-furan (TCDF) using 20 mM sodium cholate, 20 mM sodium tetraborate-decahydrate with 5% v/v...

Full description

Saved in:
Bibliographic Details
Main Authors: Wan Ibrahim, Wan Aini, Sanagi, Mohd. Marsin, Liew, Sharain
Format: Article
Published: Malaysian Society of Analytical Sciences 2009
Subjects:
Online Access:http://eprints.utm.my/466/
http://www.ukm.my/mjas/v13_n1/Wan%20Aini.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1845470283813617664
author Wan Ibrahim, Wan Aini
Sanagi, Mohd. Marsin
Liew, Sharain
author_facet Wan Ibrahim, Wan Aini
Sanagi, Mohd. Marsin
Liew, Sharain
author_sort Wan Ibrahim, Wan Aini
building UTM Library
collection Institutional Repository
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
continent Asia
country Malaysia
description Micellar electrokinetic chromatography (MEKC) with diode array detection (DAD) was used to separate two dioxin related compounds viz. 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD) and 2,3,7,8-tetrachlorodibenzo-p-furan (TCDF) using 20 mM sodium cholate, 20 mM sodium tetraborate-decahydrate with 5% v/v organic modifier (3:1 acetonitrile-methanol). To enhance sensitivity of detection, normal stacking mode (NSM-MEKC) which is the simplest stacking mode was used just by dissolving the analytes in water and injected into the capillary as a long plug. The hydrodynamic injection time was optimized by varying the injection time length in the ranges of 1s, 4s, 10s, 20s, 30s, 40s and 50s at constant hydrodynamic pressure of 50 mbar. From the optimum injection time obtained, calibration graphs of both TCDF and TCDD were constructed to calculate the detection limit obtained. A detection sensitivity enhancement factor (SEFLOD) of 330 was achieved for 2,3,7,8-TCDD achieving a detection sensitivity of 0.05 ppm while for 2,3,7,8-TCDF the SEFLOD was 65 with a detection sensitivity of 0.34 ppm. Stacking efficiencies were compared to that of normal mode (NM- MEKC) whereby no stacking is involved.
format Article
id my.utm.eprints-466
institution Universiti Teknologi Malaysia
publishDate 2009
publisher Malaysian Society of Analytical Sciences
record_format eprints
spelling my.utm.eprints-4662012-11-19T07:23:17Z http://eprints.utm.my/466/ Normal stacking mode (NSM) in improving the detection sensitivity of dioxin related compounds using micellar electrokinetic chromatography Wan Ibrahim, Wan Aini Sanagi, Mohd. Marsin Liew, Sharain QD Chemistry Micellar electrokinetic chromatography (MEKC) with diode array detection (DAD) was used to separate two dioxin related compounds viz. 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD) and 2,3,7,8-tetrachlorodibenzo-p-furan (TCDF) using 20 mM sodium cholate, 20 mM sodium tetraborate-decahydrate with 5% v/v organic modifier (3:1 acetonitrile-methanol). To enhance sensitivity of detection, normal stacking mode (NSM-MEKC) which is the simplest stacking mode was used just by dissolving the analytes in water and injected into the capillary as a long plug. The hydrodynamic injection time was optimized by varying the injection time length in the ranges of 1s, 4s, 10s, 20s, 30s, 40s and 50s at constant hydrodynamic pressure of 50 mbar. From the optimum injection time obtained, calibration graphs of both TCDF and TCDD were constructed to calculate the detection limit obtained. A detection sensitivity enhancement factor (SEFLOD) of 330 was achieved for 2,3,7,8-TCDD achieving a detection sensitivity of 0.05 ppm while for 2,3,7,8-TCDF the SEFLOD was 65 with a detection sensitivity of 0.34 ppm. Stacking efficiencies were compared to that of normal mode (NM- MEKC) whereby no stacking is involved. Malaysian Society of Analytical Sciences 2009 Article PeerReviewed Wan Ibrahim, Wan Aini and Sanagi, Mohd. Marsin and Liew, Sharain (2009) Normal stacking mode (NSM) in improving the detection sensitivity of dioxin related compounds using micellar electrokinetic chromatography. The Malaysian Journal of Analytical Sciences, 13 (1). pp. 44-51. ISSN 1394-2506 http://www.ukm.my/mjas/v13_n1/Wan%20Aini.pdf
spellingShingle QD Chemistry
Wan Ibrahim, Wan Aini
Sanagi, Mohd. Marsin
Liew, Sharain
Normal stacking mode (NSM) in improving the detection sensitivity of dioxin related compounds using micellar electrokinetic chromatography
title Normal stacking mode (NSM) in improving the detection sensitivity of dioxin related compounds using micellar electrokinetic chromatography
title_full Normal stacking mode (NSM) in improving the detection sensitivity of dioxin related compounds using micellar electrokinetic chromatography
title_fullStr Normal stacking mode (NSM) in improving the detection sensitivity of dioxin related compounds using micellar electrokinetic chromatography
title_full_unstemmed Normal stacking mode (NSM) in improving the detection sensitivity of dioxin related compounds using micellar electrokinetic chromatography
title_short Normal stacking mode (NSM) in improving the detection sensitivity of dioxin related compounds using micellar electrokinetic chromatography
title_sort normal stacking mode (nsm) in improving the detection sensitivity of dioxin related compounds using micellar electrokinetic chromatography
topic QD Chemistry
url http://eprints.utm.my/466/
http://www.ukm.my/mjas/v13_n1/Wan%20Aini.pdf
url_provider http://eprints.utm.my/