Particle size characteristics of a palm oil mill boiler flyash

A size distribution measurement of a palm oil mill fly ash samples collected at the stack exit downstream of a mill boiler was made. Results show that the geometric mean particle size was between 1.28 to 1.68 micron. Almost 90% of the fly ash falls well below 4 um size diameter and this could pose p...

Full description

Saved in:
Bibliographic Details
Main Authors: Mohd. Yusoff, Mohd. Rashid, Abdul Aziz, Ramlan, Shafil, Azman Firdaus
Format: Conference or Workshop Item
Language:en
Published: UTM 1987
Subjects:
Online Access:http://eprints.utm.my/3788/1/SKMBT_60007061915312.pdf
http://eprints.utm.my/3788/
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1845470969086345216
author Mohd. Yusoff, Mohd. Rashid
Abdul Aziz, Ramlan
Shafil, Azman Firdaus
author_facet Mohd. Yusoff, Mohd. Rashid
Abdul Aziz, Ramlan
Shafil, Azman Firdaus
author_sort Mohd. Yusoff, Mohd. Rashid
building UTM Library
collection Institutional Repository
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
continent Asia
country Malaysia
description A size distribution measurement of a palm oil mill fly ash samples collected at the stack exit downstream of a mill boiler was made. Results show that the geometric mean particle size was between 1.28 to 1.68 micron. Almost 90% of the fly ash falls well below 4 um size diameter and this could pose potential health hazard since these pasticles are in the respirable particulate size region. Other significant characteristics of the fly ash particulate are further discussed in the paper.
format Conference or Workshop Item
id my.utm.eprints-3788
institution Universiti Teknologi Malaysia
language en
publishDate 1987
publisher UTM
record_format eprints
spelling my.utm.eprints-37882017-07-25T05:47:05Z http://eprints.utm.my/3788/ Particle size characteristics of a palm oil mill boiler flyash Mohd. Yusoff, Mohd. Rashid Abdul Aziz, Ramlan Shafil, Azman Firdaus TP Chemical technology A size distribution measurement of a palm oil mill fly ash samples collected at the stack exit downstream of a mill boiler was made. Results show that the geometric mean particle size was between 1.28 to 1.68 micron. Almost 90% of the fly ash falls well below 4 um size diameter and this could pose potential health hazard since these pasticles are in the respirable particulate size region. Other significant characteristics of the fly ash particulate are further discussed in the paper. UTM 1987-11-19 Conference or Workshop Item PeerReviewed application/pdf en http://eprints.utm.my/3788/1/SKMBT_60007061915312.pdf Mohd. Yusoff, Mohd. Rashid and Abdul Aziz, Ramlan and Shafil, Azman Firdaus (1987) Particle size characteristics of a palm oil mill boiler flyash. In: Seminar on : Modern Method of Particle Characterization, 19 November 1987.
spellingShingle TP Chemical technology
Mohd. Yusoff, Mohd. Rashid
Abdul Aziz, Ramlan
Shafil, Azman Firdaus
Particle size characteristics of a palm oil mill boiler flyash
title Particle size characteristics of a palm oil mill boiler flyash
title_full Particle size characteristics of a palm oil mill boiler flyash
title_fullStr Particle size characteristics of a palm oil mill boiler flyash
title_full_unstemmed Particle size characteristics of a palm oil mill boiler flyash
title_short Particle size characteristics of a palm oil mill boiler flyash
title_sort particle size characteristics of a palm oil mill boiler flyash
topic TP Chemical technology
url http://eprints.utm.my/3788/1/SKMBT_60007061915312.pdf
http://eprints.utm.my/3788/
url_provider http://eprints.utm.my/