Determination of sources of aerosol in Chicago by chemical element mass balance

A chemical element mass balance (CEB) receptor model was used to determine the contributions from cool combustion cement and limestone, mobile sources, refuse incineration, soil and steel industries to the ambient particulate matter in Chicago. Twenty-four hour overage measurements were made of i...

Full description

Saved in:
Bibliographic Details
Main Authors: Mohd. Yusoff, Mohd. Rashid, Scheff, Peter Allan
Format: Article
Language:en
Published: 1987
Subjects:
Online Access:http://eprints.utm.my/3786/1/SKMBT_60007061915310.pdf
http://eprints.utm.my/3786/
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1845470968509628416
author Mohd. Yusoff, Mohd. Rashid
Scheff, Peter Allan
author_facet Mohd. Yusoff, Mohd. Rashid
Scheff, Peter Allan
author_sort Mohd. Yusoff, Mohd. Rashid
building UTM Library
collection Institutional Repository
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
continent Asia
country Malaysia
description A chemical element mass balance (CEB) receptor model was used to determine the contributions from cool combustion cement and limestone, mobile sources, refuse incineration, soil and steel industries to the ambient particulate matter in Chicago. Twenty-four hour overage measurements were made of inholable particulate (IP) matter consisting of fine particles (FP) diameter <2.5 um and coarse particles (CP) diameter >2.5 um but <15 um: sulfur (as SO4--) and the concentration of Al, Br, Ca, Co, Cr, Cu, Fe, K, Mg, Mn, Na, Ni, Pb, Se, Si, Ti, V and Zn for both size fractions: and SO2, temperature, wind speed and wind direction on 17 days during a 4 month period from May to August a984. The CEB was applied as an independent analysis to each sampling day. The average FP, CP and IP concentrations were 21. Ø ug/m³, 28.4 ug/m³ and 49.4 ug/m³ respectively. Based on study period overage cool, limestone, mobile, refuse, soil and steel contributes Ø.4Ø ug/m³, 7.7 ug/m³, 5.1 ug/m³ , 7.8 ug/m³ , 5.5 ug/m³ and 1.2 ug/m³ of the IP respectively. The contribution from the unexplained particulate matter were 16.3 ug/m³ , 5.9 ug/m³ and 21.6 ug/m³ for the FP, CP and IP respectively. This suggest that the aerosol is concentrated in the small size fractions contributes by the secondary pollutants. On average, the model was able to explain 22.2%, 79.3% and 56.3% of the FP, CP and IP respectively for the Chicago site.
format Article
id my.utm.eprints-3786
institution Universiti Teknologi Malaysia
language en
publishDate 1987
record_format eprints
spelling my.utm.eprints-37862010-06-01T03:12:12Z http://eprints.utm.my/3786/ Determination of sources of aerosol in Chicago by chemical element mass balance Mohd. Yusoff, Mohd. Rashid Scheff, Peter Allan TP Chemical technology A chemical element mass balance (CEB) receptor model was used to determine the contributions from cool combustion cement and limestone, mobile sources, refuse incineration, soil and steel industries to the ambient particulate matter in Chicago. Twenty-four hour overage measurements were made of inholable particulate (IP) matter consisting of fine particles (FP) diameter <2.5 um and coarse particles (CP) diameter >2.5 um but <15 um: sulfur (as SO4--) and the concentration of Al, Br, Ca, Co, Cr, Cu, Fe, K, Mg, Mn, Na, Ni, Pb, Se, Si, Ti, V and Zn for both size fractions: and SO2, temperature, wind speed and wind direction on 17 days during a 4 month period from May to August a984. The CEB was applied as an independent analysis to each sampling day. The average FP, CP and IP concentrations were 21. Ø ug/m³, 28.4 ug/m³ and 49.4 ug/m³ respectively. Based on study period overage cool, limestone, mobile, refuse, soil and steel contributes Ø.4Ø ug/m³, 7.7 ug/m³, 5.1 ug/m³ , 7.8 ug/m³ , 5.5 ug/m³ and 1.2 ug/m³ of the IP respectively. The contribution from the unexplained particulate matter were 16.3 ug/m³ , 5.9 ug/m³ and 21.6 ug/m³ for the FP, CP and IP respectively. This suggest that the aerosol is concentrated in the small size fractions contributes by the secondary pollutants. On average, the model was able to explain 22.2%, 79.3% and 56.3% of the FP, CP and IP respectively for the Chicago site. 1987-11 Article PeerReviewed application/pdf en http://eprints.utm.my/3786/1/SKMBT_60007061915310.pdf Mohd. Yusoff, Mohd. Rashid and Scheff, Peter Allan (1987) Determination of sources of aerosol in Chicago by chemical element mass balance. Chemical Element . pp. 1-16.
spellingShingle TP Chemical technology
Mohd. Yusoff, Mohd. Rashid
Scheff, Peter Allan
Determination of sources of aerosol in Chicago by chemical element mass balance
title Determination of sources of aerosol in Chicago by chemical element mass balance
title_full Determination of sources of aerosol in Chicago by chemical element mass balance
title_fullStr Determination of sources of aerosol in Chicago by chemical element mass balance
title_full_unstemmed Determination of sources of aerosol in Chicago by chemical element mass balance
title_short Determination of sources of aerosol in Chicago by chemical element mass balance
title_sort determination of sources of aerosol in chicago by chemical element mass balance
topic TP Chemical technology
url http://eprints.utm.my/3786/1/SKMBT_60007061915310.pdf
http://eprints.utm.my/3786/
url_provider http://eprints.utm.my/