Fault analysis on double three-phase to six-phase converted transmission line

High phase order transmission system is being considered a viable alternative for increasing the power transmission capability of overhead electric power transmission over existing right-of-way. This paper presents the faults analysis of six-phase transmission system. In this context, fault analysis...

Full description

Saved in:
Bibliographic Details
Main Authors: Mustafa, M. W., Ahmad, M. R., Shareef, H.
Format: Article
Language:en
Published: IEEE 2005
Subjects:
Online Access:http://eprints.utm.my/1648/1/wazir05_Fault_analysis_on_double_three_phase.pdf
http://eprints.utm.my/1648/
http://ieeexplore.ieee.org/document/1627348/?arnumber=1627348
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1845470512492314624
author Mustafa, M. W.
Ahmad, M. R.
Shareef, H.
author_facet Mustafa, M. W.
Ahmad, M. R.
Shareef, H.
author_sort Mustafa, M. W.
building UTM Library
collection Institutional Repository
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
continent Asia
country Malaysia
description High phase order transmission system is being considered a viable alternative for increasing the power transmission capability of overhead electric power transmission over existing right-of-way. This paper presents the faults analysis of six-phase transmission system. In this context, fault analysis has been conducted on the Goudey-Oakdale 2-bus test system. The results of these investigations are presented in the form of typical time responses. The PSCAD/EMTDC is used for the simulation studies.
format Article
id my.utm.eprints-1648
institution Universiti Teknologi Malaysia
language en
publishDate 2005
publisher IEEE
record_format eprints
spelling my.utm.eprints-16482017-04-16T07:38:14Z http://eprints.utm.my/1648/ Fault analysis on double three-phase to six-phase converted transmission line Mustafa, M. W. Ahmad, M. R. Shareef, H. TK Electrical engineering. Electronics Nuclear engineering High phase order transmission system is being considered a viable alternative for increasing the power transmission capability of overhead electric power transmission over existing right-of-way. This paper presents the faults analysis of six-phase transmission system. In this context, fault analysis has been conducted on the Goudey-Oakdale 2-bus test system. The results of these investigations are presented in the form of typical time responses. The PSCAD/EMTDC is used for the simulation studies. IEEE 2005-11-29 Article PeerReviewed application/pdf en http://eprints.utm.my/1648/1/wazir05_Fault_analysis_on_double_three_phase.pdf Mustafa, M. W. and Ahmad, M. R. and Shareef, H. (2005) Fault analysis on double three-phase to six-phase converted transmission line. The 7th International Conference on Power Engineering, 2 . pp. 1030-1034. http://ieeexplore.ieee.org/document/1627348/?arnumber=1627348
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Mustafa, M. W.
Ahmad, M. R.
Shareef, H.
Fault analysis on double three-phase to six-phase converted transmission line
title Fault analysis on double three-phase to six-phase converted transmission line
title_full Fault analysis on double three-phase to six-phase converted transmission line
title_fullStr Fault analysis on double three-phase to six-phase converted transmission line
title_full_unstemmed Fault analysis on double three-phase to six-phase converted transmission line
title_short Fault analysis on double three-phase to six-phase converted transmission line
title_sort fault analysis on double three-phase to six-phase converted transmission line
topic TK Electrical engineering. Electronics Nuclear engineering
url http://eprints.utm.my/1648/1/wazir05_Fault_analysis_on_double_three_phase.pdf
http://eprints.utm.my/1648/
http://ieeexplore.ieee.org/document/1627348/?arnumber=1627348
url_provider http://eprints.utm.my/