Heavy metals Mn, Fe, Ni, Cu and Zn in human hair samples using energy dispersive X-ray fluorescence analysis

This paper presents the results of analysis of energy-dispersive X-ray fluorescence (EDXRF) applied on the human hair. We determined the concentrations of heavy metals Mn, Fe, Ni, Cu and Zn of 29 hair samples of sanitation workers and 5 samples of students were assumed to be environmentally health...

Full description

Saved in:
Bibliographic Details
Main Authors: Md Khudzari, Jauharah, Wagiran, Husin, Hossain, Md. Imam, Ibrahim, Noorddin, Agam, Mohd Arif
Format: Article
Language:en
Published: 2011
Subjects:
Online Access:http://eprints.uthm.edu.my/7977/1/J4209_770f5d2c29734aef290de6bb1fd953b8.pdf
http://eprints.uthm.edu.my/7977/
https://doi.org/10.5897/IJPS11.073
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1833418535340081152
author Md Khudzari, Jauharah
Wagiran, Husin
Hossain, Md. Imam
Ibrahim, Noorddin
Agam, Mohd Arif
author_facet Md Khudzari, Jauharah
Wagiran, Husin
Hossain, Md. Imam
Ibrahim, Noorddin
Agam, Mohd Arif
author_sort Md Khudzari, Jauharah
building UTHM Library
collection Institutional Repository
content_provider Universiti Tun Hussein Onn Malaysia
content_source UTHM Institutional Repository
continent Asia
country Malaysia
description This paper presents the results of analysis of energy-dispersive X-ray fluorescence (EDXRF) applied on the human hair. We determined the concentrations of heavy metals Mn, Fe, Ni, Cu and Zn of 29 hair samples of sanitation workers and 5 samples of students were assumed to be environmentally healthy group. The accuracy and precision of the method for the elements were evaluated through the analysis of a standard hair sample. We compared the concentrations of human hair from an occupationally exposed group of sanitation workers and a control group (students). The hair of the exposed group showed a range of concentrations of 6-28 ppm Mn, 20-195 ppm Fe, 258-549 ppm Ni, 452-1182 ppm Cu and 334-1556 ppm Zn, while that of the control group has a range of 7-26 ppm Mn, 22-61 ppm Fe, 309- 558 ppm Ni, 438-700 ppm Cu and 224-876 ppm Zn.
format Article
id my.uthm.eprints-7977
institution Universiti Tun Hussein Onn Malaysia
language en
publishDate 2011
record_format eprints
spelling my.uthm.eprints-79772022-11-08T01:36:13Z http://eprints.uthm.edu.my/7977/ Heavy metals Mn, Fe, Ni, Cu and Zn in human hair samples using energy dispersive X-ray fluorescence analysis Md Khudzari, Jauharah Wagiran, Husin Hossain, Md. Imam Ibrahim, Noorddin Agam, Mohd Arif T Technology (General) This paper presents the results of analysis of energy-dispersive X-ray fluorescence (EDXRF) applied on the human hair. We determined the concentrations of heavy metals Mn, Fe, Ni, Cu and Zn of 29 hair samples of sanitation workers and 5 samples of students were assumed to be environmentally healthy group. The accuracy and precision of the method for the elements were evaluated through the analysis of a standard hair sample. We compared the concentrations of human hair from an occupationally exposed group of sanitation workers and a control group (students). The hair of the exposed group showed a range of concentrations of 6-28 ppm Mn, 20-195 ppm Fe, 258-549 ppm Ni, 452-1182 ppm Cu and 334-1556 ppm Zn, while that of the control group has a range of 7-26 ppm Mn, 22-61 ppm Fe, 309- 558 ppm Ni, 438-700 ppm Cu and 224-876 ppm Zn. 2011 Article PeerReviewed text en http://eprints.uthm.edu.my/7977/1/J4209_770f5d2c29734aef290de6bb1fd953b8.pdf Md Khudzari, Jauharah and Wagiran, Husin and Hossain, Md. Imam and Ibrahim, Noorddin and Agam, Mohd Arif (2011) Heavy metals Mn, Fe, Ni, Cu and Zn in human hair samples using energy dispersive X-ray fluorescence analysis. International Journal of the Physical Sciences, 6 (8). pp. 2090-2094. https://doi.org/10.5897/IJPS11.073
spellingShingle T Technology (General)
Md Khudzari, Jauharah
Wagiran, Husin
Hossain, Md. Imam
Ibrahim, Noorddin
Agam, Mohd Arif
Heavy metals Mn, Fe, Ni, Cu and Zn in human hair samples using energy dispersive X-ray fluorescence analysis
title Heavy metals Mn, Fe, Ni, Cu and Zn in human hair samples using energy dispersive X-ray fluorescence analysis
title_full Heavy metals Mn, Fe, Ni, Cu and Zn in human hair samples using energy dispersive X-ray fluorescence analysis
title_fullStr Heavy metals Mn, Fe, Ni, Cu and Zn in human hair samples using energy dispersive X-ray fluorescence analysis
title_full_unstemmed Heavy metals Mn, Fe, Ni, Cu and Zn in human hair samples using energy dispersive X-ray fluorescence analysis
title_short Heavy metals Mn, Fe, Ni, Cu and Zn in human hair samples using energy dispersive X-ray fluorescence analysis
title_sort heavy metals mn, fe, ni, cu and zn in human hair samples using energy dispersive x-ray fluorescence analysis
topic T Technology (General)
url http://eprints.uthm.edu.my/7977/1/J4209_770f5d2c29734aef290de6bb1fd953b8.pdf
http://eprints.uthm.edu.my/7977/
https://doi.org/10.5897/IJPS11.073
url_provider http://eprints.uthm.edu.my/