A review on femoropopliteal arterial deformation during daily lives and nickel-titanium stent properties

The increasing number of studies on the behaviour of stent placement in recent decades provides a clear understanding of peripheral artery disease (PAD). The severe mechanical loads (axial ten�sion and compression, bending, radial compression and torsion) deformation of the femoropopli�teal artery...

Full description

Saved in:
Bibliographic Details
Main Authors: K. Kareem, Ali, M. Gabir, Mustafa, R. Ali, Inas, E. Ismail, Al, Taib, Ishkrizat, Darlis, Nofrizalidris, M. Almoayed, Omar
Format: Article
Language:en
Published: Taylor & Francis 2022
Subjects:
Online Access:http://eprints.uthm.edu.my/7235/1/J14098_7e5b56f764bf337616bb5bbe07dab46e.pdf
http://eprints.uthm.edu.my/7235/
https://doi.org/10.1080/03091902.2022.2041749
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1833418318501904384
author K. Kareem, Ali
M. Gabir, Mustafa
R. Ali, Inas
E. Ismail, Al
Taib, Ishkrizat
Darlis, Nofrizalidris
M. Almoayed, Omar
author_facet K. Kareem, Ali
M. Gabir, Mustafa
R. Ali, Inas
E. Ismail, Al
Taib, Ishkrizat
Darlis, Nofrizalidris
M. Almoayed, Omar
author_sort K. Kareem, Ali
building UTHM Library
collection Institutional Repository
content_provider Universiti Tun Hussein Onn Malaysia
content_source UTHM Institutional Repository
continent Asia
country Malaysia
description The increasing number of studies on the behaviour of stent placement in recent decades provides a clear understanding of peripheral artery disease (PAD). The severe mechanical loads (axial ten�sion and compression, bending, radial compression and torsion) deformation of the femoropopli�teal artery (FPA) is responsible for the highest failure rate of permanent nickel-titanium (Nitinol) stents. Therefore, the purpose of this article is to review research papers that examined the deformation of the natural load environment of FPA, the properties of Nitinol and mechanical considerations. In conclusion, a better understanding of mechanical behaviour for FPA Nitinol stents contributes to increased mechanical performance and fatigue-life.
format Article
id my.uthm.eprints-7235
institution Universiti Tun Hussein Onn Malaysia
language en
publishDate 2022
publisher Taylor & Francis
record_format eprints
spelling my.uthm.eprints-72352022-07-03T07:56:47Z http://eprints.uthm.edu.my/7235/ A review on femoropopliteal arterial deformation during daily lives and nickel-titanium stent properties K. Kareem, Ali M. Gabir, Mustafa R. Ali, Inas E. Ismail, Al Taib, Ishkrizat Darlis, Nofrizalidris M. Almoayed, Omar TA401-492 Materials of engineering and construction. Mechanics of materials The increasing number of studies on the behaviour of stent placement in recent decades provides a clear understanding of peripheral artery disease (PAD). The severe mechanical loads (axial ten�sion and compression, bending, radial compression and torsion) deformation of the femoropopli�teal artery (FPA) is responsible for the highest failure rate of permanent nickel-titanium (Nitinol) stents. Therefore, the purpose of this article is to review research papers that examined the deformation of the natural load environment of FPA, the properties of Nitinol and mechanical considerations. In conclusion, a better understanding of mechanical behaviour for FPA Nitinol stents contributes to increased mechanical performance and fatigue-life. Taylor & Francis 2022 Article PeerReviewed text en http://eprints.uthm.edu.my/7235/1/J14098_7e5b56f764bf337616bb5bbe07dab46e.pdf K. Kareem, Ali and M. Gabir, Mustafa and R. Ali, Inas and E. Ismail, Al and Taib, Ishkrizat and Darlis, Nofrizalidris and M. Almoayed, Omar (2022) A review on femoropopliteal arterial deformation during daily lives and nickel-titanium stent properties. JOURNAL OF MEDICAL ENGINEERING & TECHNOLOGY, 46 (4). pp. 300-317. https://doi.org/10.1080/03091902.2022.2041749
spellingShingle TA401-492 Materials of engineering and construction. Mechanics of materials
K. Kareem, Ali
M. Gabir, Mustafa
R. Ali, Inas
E. Ismail, Al
Taib, Ishkrizat
Darlis, Nofrizalidris
M. Almoayed, Omar
A review on femoropopliteal arterial deformation during daily lives and nickel-titanium stent properties
title A review on femoropopliteal arterial deformation during daily lives and nickel-titanium stent properties
title_full A review on femoropopliteal arterial deformation during daily lives and nickel-titanium stent properties
title_fullStr A review on femoropopliteal arterial deformation during daily lives and nickel-titanium stent properties
title_full_unstemmed A review on femoropopliteal arterial deformation during daily lives and nickel-titanium stent properties
title_short A review on femoropopliteal arterial deformation during daily lives and nickel-titanium stent properties
title_sort review on femoropopliteal arterial deformation during daily lives and nickel-titanium stent properties
topic TA401-492 Materials of engineering and construction. Mechanics of materials
url http://eprints.uthm.edu.my/7235/1/J14098_7e5b56f764bf337616bb5bbe07dab46e.pdf
http://eprints.uthm.edu.my/7235/
https://doi.org/10.1080/03091902.2022.2041749
url_provider http://eprints.uthm.edu.my/