A review on magnetic induction spectroscopy potential for fetal acidosis examination

Fetal acidosis is one of the main concerns during labor. Currently, fetal blood sampling (FBS) has become the most accurate measurement of acidosis detection. However, it is invasive and does not provide a real time measurement due to laboratory procedures. Delays in diagnosis of acidosis have cause...

Full description

Saved in:
Bibliographic Details
Main Authors: Abdul Halim, Siti Fatimah, Zakaria, Zulkarnay, Pusppanathan, Jaysuman, Mohd Noor, Anas, Norali, Ahmad Nasrul, Rahiman, Mohd Hafiz Fazalul, Mohd Muji, Siti Zarina, Abdul Rahim, Ruzairi, Engku-Husna, Engku Ismail, Ali Hassan, Muhamad Khairul, Safar, Muhammad Juhairi Aziz, Salleh, Ahmad Faizal, Mat Som, Mohd Hanafi
Format: Article
Language:en
Published: 2022
Subjects:
Online Access:http://eprints.uthm.edu.my/6896/1/J13988_cc4145e3d9eb2dfde5f37d23de1b5c7e.pdf
http://eprints.uthm.edu.my/6896/
https://doi.org/10.3390/s22041334
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1833418221805371392
author Abdul Halim, Siti Fatimah
Zakaria, Zulkarnay
Pusppanathan, Jaysuman
Mohd Noor, Anas
Norali, Ahmad Nasrul
Rahiman, Mohd Hafiz Fazalul
Mohd Muji, Siti Zarina
Abdul Rahim, Ruzairi
Engku-Husna, Engku Ismail
Ali Hassan, Muhamad Khairul
Safar, Muhammad Juhairi Aziz
Salleh, Ahmad Faizal
Mat Som, Mohd Hanafi
author_facet Abdul Halim, Siti Fatimah
Zakaria, Zulkarnay
Pusppanathan, Jaysuman
Mohd Noor, Anas
Norali, Ahmad Nasrul
Rahiman, Mohd Hafiz Fazalul
Mohd Muji, Siti Zarina
Abdul Rahim, Ruzairi
Engku-Husna, Engku Ismail
Ali Hassan, Muhamad Khairul
Safar, Muhammad Juhairi Aziz
Salleh, Ahmad Faizal
Mat Som, Mohd Hanafi
author_sort Abdul Halim, Siti Fatimah
building UTHM Library
collection Institutional Repository
content_provider Universiti Tun Hussein Onn Malaysia
content_source UTHM Institutional Repository
continent Asia
country Malaysia
description Fetal acidosis is one of the main concerns during labor. Currently, fetal blood sampling (FBS) has become the most accurate measurement of acidosis detection. However, it is invasive and does not provide a real time measurement due to laboratory procedures. Delays in diagnosis of acidosis have caused serious injury to the fetus, especially for the brain and the heart. This paper reviews the new technique in diagnosis of acidosis non-invasively. Magnetic Induction Spectroscopy (MIS) has been proposed to be a new device for acidosis detection in recent years. This paper explains the basic principle of MIS and outlines the design specifications and design considerations for a MIS pH probe. It is expected that readers will gain a basic understanding of the development of a MIS pH probe from this review.
format Article
id my.uthm.eprints-6896
institution Universiti Tun Hussein Onn Malaysia
language en
publishDate 2022
record_format eprints
spelling my.uthm.eprints-68962022-04-12T06:34:31Z http://eprints.uthm.edu.my/6896/ A review on magnetic induction spectroscopy potential for fetal acidosis examination Abdul Halim, Siti Fatimah Zakaria, Zulkarnay Pusppanathan, Jaysuman Mohd Noor, Anas Norali, Ahmad Nasrul Rahiman, Mohd Hafiz Fazalul Mohd Muji, Siti Zarina Abdul Rahim, Ruzairi Engku-Husna, Engku Ismail Ali Hassan, Muhamad Khairul Safar, Muhammad Juhairi Aziz Salleh, Ahmad Faizal Mat Som, Mohd Hanafi TP Chemical technology Fetal acidosis is one of the main concerns during labor. Currently, fetal blood sampling (FBS) has become the most accurate measurement of acidosis detection. However, it is invasive and does not provide a real time measurement due to laboratory procedures. Delays in diagnosis of acidosis have caused serious injury to the fetus, especially for the brain and the heart. This paper reviews the new technique in diagnosis of acidosis non-invasively. Magnetic Induction Spectroscopy (MIS) has been proposed to be a new device for acidosis detection in recent years. This paper explains the basic principle of MIS and outlines the design specifications and design considerations for a MIS pH probe. It is expected that readers will gain a basic understanding of the development of a MIS pH probe from this review. 2022 Article PeerReviewed text en http://eprints.uthm.edu.my/6896/1/J13988_cc4145e3d9eb2dfde5f37d23de1b5c7e.pdf Abdul Halim, Siti Fatimah and Zakaria, Zulkarnay and Pusppanathan, Jaysuman and Mohd Noor, Anas and Norali, Ahmad Nasrul and Rahiman, Mohd Hafiz Fazalul and Mohd Muji, Siti Zarina and Abdul Rahim, Ruzairi and Engku-Husna, Engku Ismail and Ali Hassan, Muhamad Khairul and Safar, Muhammad Juhairi Aziz and Salleh, Ahmad Faizal and Mat Som, Mohd Hanafi (2022) A review on magnetic induction spectroscopy potential for fetal acidosis examination. National Library of Medicine, 22 (4). https://doi.org/10.3390/s22041334
spellingShingle TP Chemical technology
Abdul Halim, Siti Fatimah
Zakaria, Zulkarnay
Pusppanathan, Jaysuman
Mohd Noor, Anas
Norali, Ahmad Nasrul
Rahiman, Mohd Hafiz Fazalul
Mohd Muji, Siti Zarina
Abdul Rahim, Ruzairi
Engku-Husna, Engku Ismail
Ali Hassan, Muhamad Khairul
Safar, Muhammad Juhairi Aziz
Salleh, Ahmad Faizal
Mat Som, Mohd Hanafi
A review on magnetic induction spectroscopy potential for fetal acidosis examination
title A review on magnetic induction spectroscopy potential for fetal acidosis examination
title_full A review on magnetic induction spectroscopy potential for fetal acidosis examination
title_fullStr A review on magnetic induction spectroscopy potential for fetal acidosis examination
title_full_unstemmed A review on magnetic induction spectroscopy potential for fetal acidosis examination
title_short A review on magnetic induction spectroscopy potential for fetal acidosis examination
title_sort review on magnetic induction spectroscopy potential for fetal acidosis examination
topic TP Chemical technology
url http://eprints.uthm.edu.my/6896/1/J13988_cc4145e3d9eb2dfde5f37d23de1b5c7e.pdf
http://eprints.uthm.edu.my/6896/
https://doi.org/10.3390/s22041334
url_provider http://eprints.uthm.edu.my/