Leachate treatment using up-flow anaerobic sludge blanket system

Leachate is one of the major problems to overcome in managing the landfill. Low cost treatment, less maintenance and environmental friendly are the target on how to treat the leachate. This research focused on the effectiveness of Up-flow Anaerobic Sludge Blanket on leachate treatment. This study wa...

Full description

Saved in:
Bibliographic Details
Main Authors: Ridzuan, Mohd Baharudin, Daud, Zawawi, Ahmad, Zulkifli, Abd Latiff, Ab Aziz, Awang, Halizah
Format: Article
Language:en
Published: Penerbit UTHM 2018
Subjects:
Online Access:http://eprints.uthm.edu.my/4477/1/AJ%202018%20%2890%29.pdf
http://eprints.uthm.edu.my/4477/
https://doi.org/10.30880/ijie.2018.10.01.010
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1833417609466347520
author Ridzuan, Mohd Baharudin
Daud, Zawawi
Ahmad, Zulkifli
Abd Latiff, Ab Aziz
Awang, Halizah
author_facet Ridzuan, Mohd Baharudin
Daud, Zawawi
Ahmad, Zulkifli
Abd Latiff, Ab Aziz
Awang, Halizah
author_sort Ridzuan, Mohd Baharudin
building UTHM Library
collection Institutional Repository
content_provider Universiti Tun Hussein Onn Malaysia
content_source UTHM Institutional Repository
continent Asia
country Malaysia
description Leachate is one of the major problems to overcome in managing the landfill. Low cost treatment, less maintenance and environmental friendly are the target on how to treat the leachate. This research focused on the effectiveness of Up-flow Anaerobic Sludge Blanket on leachate treatment. This study was carried out upon treatment of leachate by using Up-flow Anaerobic Sludge Blanket through reactor tank in lab-scale. Without a proper treatment, leachate will give a negative effect to the environment and become pollutant. This research is determining percentage nutrient removal on leachate. The leachate characteristic also been investigated. The main parameters evaluations are Biochemical Oxygen Demand (BOD), Chemical Oxygen Demand (COD), Total Suspended Solid (TSS), Total Nitrogen (TN) and Total Phosphorus (TP). Experiments were run in duration of 30 days were sample for test had been taken each 3 days. Results show that the capability of UASB in the removal several parameters. This UASB had a greater ability in removal of Total Phosphorus and TSS with 89% and 81% respectively. For COD, BOD and TN, the values are 74%, 64% and 50%. Based on these results, it clearly shows that UASB capable to remove physical and chemical properties of leachate.
format Article
id my.uthm.eprints-4477
institution Universiti Tun Hussein Onn Malaysia
language en
publishDate 2018
publisher Penerbit UTHM
record_format eprints
spelling my.uthm.eprints-44772021-12-07T04:02:34Z http://eprints.uthm.edu.my/4477/ Leachate treatment using up-flow anaerobic sludge blanket system Ridzuan, Mohd Baharudin Daud, Zawawi Ahmad, Zulkifli Abd Latiff, Ab Aziz Awang, Halizah T Technology (General) TD511-780 Sewage collection and disposal systems. Sewerage Leachate is one of the major problems to overcome in managing the landfill. Low cost treatment, less maintenance and environmental friendly are the target on how to treat the leachate. This research focused on the effectiveness of Up-flow Anaerobic Sludge Blanket on leachate treatment. This study was carried out upon treatment of leachate by using Up-flow Anaerobic Sludge Blanket through reactor tank in lab-scale. Without a proper treatment, leachate will give a negative effect to the environment and become pollutant. This research is determining percentage nutrient removal on leachate. The leachate characteristic also been investigated. The main parameters evaluations are Biochemical Oxygen Demand (BOD), Chemical Oxygen Demand (COD), Total Suspended Solid (TSS), Total Nitrogen (TN) and Total Phosphorus (TP). Experiments were run in duration of 30 days were sample for test had been taken each 3 days. Results show that the capability of UASB in the removal several parameters. This UASB had a greater ability in removal of Total Phosphorus and TSS with 89% and 81% respectively. For COD, BOD and TN, the values are 74%, 64% and 50%. Based on these results, it clearly shows that UASB capable to remove physical and chemical properties of leachate. Penerbit UTHM 2018 Article PeerReviewed text en http://eprints.uthm.edu.my/4477/1/AJ%202018%20%2890%29.pdf Ridzuan, Mohd Baharudin and Daud, Zawawi and Ahmad, Zulkifli and Abd Latiff, Ab Aziz and Awang, Halizah (2018) Leachate treatment using up-flow anaerobic sludge blanket system. International Journal of Integrated Engineering, 10 (1). pp. 62-65. ISSN 2229-838X https://doi.org/10.30880/ijie.2018.10.01.010
spellingShingle T Technology (General)
TD511-780 Sewage collection and disposal systems. Sewerage
Ridzuan, Mohd Baharudin
Daud, Zawawi
Ahmad, Zulkifli
Abd Latiff, Ab Aziz
Awang, Halizah
Leachate treatment using up-flow anaerobic sludge blanket system
title Leachate treatment using up-flow anaerobic sludge blanket system
title_full Leachate treatment using up-flow anaerobic sludge blanket system
title_fullStr Leachate treatment using up-flow anaerobic sludge blanket system
title_full_unstemmed Leachate treatment using up-flow anaerobic sludge blanket system
title_short Leachate treatment using up-flow anaerobic sludge blanket system
title_sort leachate treatment using up-flow anaerobic sludge blanket system
topic T Technology (General)
TD511-780 Sewage collection and disposal systems. Sewerage
url http://eprints.uthm.edu.my/4477/1/AJ%202018%20%2890%29.pdf
http://eprints.uthm.edu.my/4477/
https://doi.org/10.30880/ijie.2018.10.01.010
url_provider http://eprints.uthm.edu.my/