Mobile electrical capacitance tomography (ECT) development for liquid-gas flow measurement

Electrical capacitance tomography (ECT) system is useful to obtain information on spatial distribution of dielectric material mixture inside a vessel. This paper discusses a sixteen-electrode mobile ECT sensing system which is developed non-invasively and non-intrusively. Emphases on the software de...

Full description

Saved in:
Bibliographic Details
Main Authors: Chan, Kok Seong, Pusppanathan, Jaysuman, Abdul Rahim, Ruzairi, Susiapan, Yvette Shaan-Li, Phang, Fatin Aliah, Rahiman, Mohd Hafiz Fazalul, Awang, Zubaidah, Ahmad, Anita, Abdul Wahid, Herman, Mohamad, Elmy Johana, Ridzuan Aw, Suzanna
Format: Article
Language:en
Published: Penerbit UTM Press 2015
Subjects:
Online Access:http://eprints.uthm.edu.my/3524/1/AJ%202017%20%2870%29%20Mobile%20electrical%20capacitance%20tomography.pdf
http://eprints.uthm.edu.my/3524/
http://www.jurnalteknologi.utm.my
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1833417359985999872
author Chan, Kok Seong
Pusppanathan, Jaysuman
Abdul Rahim, Ruzairi
Susiapan, Yvette Shaan-Li
Phang, Fatin Aliah
Rahiman, Mohd Hafiz Fazalul
Awang, Zubaidah
Ahmad, Anita
Abdul Wahid, Herman
Mohamad, Elmy Johana
Ridzuan Aw, Suzanna
author_facet Chan, Kok Seong
Pusppanathan, Jaysuman
Abdul Rahim, Ruzairi
Susiapan, Yvette Shaan-Li
Phang, Fatin Aliah
Rahiman, Mohd Hafiz Fazalul
Awang, Zubaidah
Ahmad, Anita
Abdul Wahid, Herman
Mohamad, Elmy Johana
Ridzuan Aw, Suzanna
author_sort Chan, Kok Seong
building UTHM Library
collection Institutional Repository
content_provider Universiti Tun Hussein Onn Malaysia
content_source UTHM Institutional Repository
continent Asia
country Malaysia
description Electrical capacitance tomography (ECT) system is useful to obtain information on spatial distribution of dielectric material mixture inside a vessel. This paper discusses a sixteen-electrode mobile ECT sensing system which is developed non-invasively and non-intrusively. Emphases on the software development aspects are presented in several sections; initialization part, normalization part, calibration part, hardware communication part and the image reconstruction part. Thus, the liquid-gas concentration profile of the ECT system is successfully acquired using the software developed.
format Article
id my.uthm.eprints-3524
institution Universiti Tun Hussein Onn Malaysia
language en
publishDate 2015
publisher Penerbit UTM Press
record_format eprints
spelling my.uthm.eprints-35242021-11-18T02:01:27Z http://eprints.uthm.edu.my/3524/ Mobile electrical capacitance tomography (ECT) development for liquid-gas flow measurement Chan, Kok Seong Pusppanathan, Jaysuman Abdul Rahim, Ruzairi Susiapan, Yvette Shaan-Li Phang, Fatin Aliah Rahiman, Mohd Hafiz Fazalul Awang, Zubaidah Ahmad, Anita Abdul Wahid, Herman Mohamad, Elmy Johana Ridzuan Aw, Suzanna TK Electrical engineering. Electronics Nuclear engineering Electrical capacitance tomography (ECT) system is useful to obtain information on spatial distribution of dielectric material mixture inside a vessel. This paper discusses a sixteen-electrode mobile ECT sensing system which is developed non-invasively and non-intrusively. Emphases on the software development aspects are presented in several sections; initialization part, normalization part, calibration part, hardware communication part and the image reconstruction part. Thus, the liquid-gas concentration profile of the ECT system is successfully acquired using the software developed. Penerbit UTM Press 2015 Article PeerReviewed text en http://eprints.uthm.edu.my/3524/1/AJ%202017%20%2870%29%20Mobile%20electrical%20capacitance%20tomography.pdf Chan, Kok Seong and Pusppanathan, Jaysuman and Abdul Rahim, Ruzairi and Susiapan, Yvette Shaan-Li and Phang, Fatin Aliah and Rahiman, Mohd Hafiz Fazalul and Awang, Zubaidah and Ahmad, Anita and Abdul Wahid, Herman and Mohamad, Elmy Johana and Ridzuan Aw, Suzanna (2015) Mobile electrical capacitance tomography (ECT) development for liquid-gas flow measurement. Jurnal Teknologi, 73 (3). pp. 29-33. ISSN 2180–3722 http://www.jurnalteknologi.utm.my
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Chan, Kok Seong
Pusppanathan, Jaysuman
Abdul Rahim, Ruzairi
Susiapan, Yvette Shaan-Li
Phang, Fatin Aliah
Rahiman, Mohd Hafiz Fazalul
Awang, Zubaidah
Ahmad, Anita
Abdul Wahid, Herman
Mohamad, Elmy Johana
Ridzuan Aw, Suzanna
Mobile electrical capacitance tomography (ECT) development for liquid-gas flow measurement
title Mobile electrical capacitance tomography (ECT) development for liquid-gas flow measurement
title_full Mobile electrical capacitance tomography (ECT) development for liquid-gas flow measurement
title_fullStr Mobile electrical capacitance tomography (ECT) development for liquid-gas flow measurement
title_full_unstemmed Mobile electrical capacitance tomography (ECT) development for liquid-gas flow measurement
title_short Mobile electrical capacitance tomography (ECT) development for liquid-gas flow measurement
title_sort mobile electrical capacitance tomography (ect) development for liquid-gas flow measurement
topic TK Electrical engineering. Electronics Nuclear engineering
url http://eprints.uthm.edu.my/3524/1/AJ%202017%20%2870%29%20Mobile%20electrical%20capacitance%20tomography.pdf
http://eprints.uthm.edu.my/3524/
http://www.jurnalteknologi.utm.my
url_provider http://eprints.uthm.edu.my/