Water reticulation model for Taman Maju, Parit Raja

A numerical model is developed to quantify energy head losses occurred in the water distribution network of Taman Maju, Parit Raja, Johor. A numerical computation has the advantage over a manual computation when analyzing a complex distribution network. The programming language used in this st...

Full description

Saved in:
Bibliographic Details
Main Author: O. Elojali, Otman Mohamed
Format: Thesis
Language:en
en
en
Published: 2011
Subjects:
Online Access:http://eprints.uthm.edu.my/2858/1/24p%20OTMAN%20MOHAMED%20O.%20ELOJALI.pdf
http://eprints.uthm.edu.my/2858/2/OTMAN%20MOHAMED%20O.%20ELOJALI%20COPYRIGHT%20DECLARATION.pdf
http://eprints.uthm.edu.my/2858/3/OTMAN%20MOHAMED%20O.%20ELOJALI%20WATERMARK.pdf
http://eprints.uthm.edu.my/2858/
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1833417183821037568
author O. Elojali, Otman Mohamed
author_facet O. Elojali, Otman Mohamed
author_sort O. Elojali, Otman Mohamed
building UTHM Library
collection Institutional Repository
content_provider Universiti Tun Hussein Onn Malaysia
content_source UTHM Institutional Repository
continent Asia
country Malaysia
description A numerical model is developed to quantify energy head losses occurred in the water distribution network of Taman Maju, Parit Raja, Johor. A numerical computation has the advantage over a manual computation when analyzing a complex distribution network. The programming language used in this study is the Microsoft Visual Basic 6.0. Hardy-Cross method is selected to calculate the total energy head loss incurred in the looped water distribution network of Taman Maju. The type of pipe used in the water distribution network of Taman Maju is the unplasticised polyvinyl chloride (uPVC) type with the roughness coefficient k = 0.0015 mm. Since Taman Maju consists of terrace houses, the water demand is 1360 litres/unit/day. Three loop networks are considered, namely loop A, B and C for Taman Maju reticulation system. The final flow rate in each pipe has been obtained. This model is helpful in reducing the period of time to calculate the flow rate which is found to be within the piping system design requirement. If comparison is made between the manual calculation, it will definitely shows some difference. The final result will be different because the decimal places fixed are different in manual and model
format Thesis
id my.uthm.eprints-2858
institution Universiti Tun Hussein Onn Malaysia
language en
en
en
publishDate 2011
record_format eprints
spelling my.uthm.eprints-28582021-11-02T03:24:57Z http://eprints.uthm.edu.my/2858/ Water reticulation model for Taman Maju, Parit Raja O. Elojali, Otman Mohamed TD Environmental technology. Sanitary engineering TD481-493 Water distribution systems A numerical model is developed to quantify energy head losses occurred in the water distribution network of Taman Maju, Parit Raja, Johor. A numerical computation has the advantage over a manual computation when analyzing a complex distribution network. The programming language used in this study is the Microsoft Visual Basic 6.0. Hardy-Cross method is selected to calculate the total energy head loss incurred in the looped water distribution network of Taman Maju. The type of pipe used in the water distribution network of Taman Maju is the unplasticised polyvinyl chloride (uPVC) type with the roughness coefficient k = 0.0015 mm. Since Taman Maju consists of terrace houses, the water demand is 1360 litres/unit/day. Three loop networks are considered, namely loop A, B and C for Taman Maju reticulation system. The final flow rate in each pipe has been obtained. This model is helpful in reducing the period of time to calculate the flow rate which is found to be within the piping system design requirement. If comparison is made between the manual calculation, it will definitely shows some difference. The final result will be different because the decimal places fixed are different in manual and model 2011-05 Thesis NonPeerReviewed text en http://eprints.uthm.edu.my/2858/1/24p%20OTMAN%20MOHAMED%20O.%20ELOJALI.pdf text en http://eprints.uthm.edu.my/2858/2/OTMAN%20MOHAMED%20O.%20ELOJALI%20COPYRIGHT%20DECLARATION.pdf text en http://eprints.uthm.edu.my/2858/3/OTMAN%20MOHAMED%20O.%20ELOJALI%20WATERMARK.pdf O. Elojali, Otman Mohamed (2011) Water reticulation model for Taman Maju, Parit Raja. Masters thesis, Universiti Tun Hussein Onn Malaysia.
spellingShingle TD Environmental technology. Sanitary engineering
TD481-493 Water distribution systems
O. Elojali, Otman Mohamed
Water reticulation model for Taman Maju, Parit Raja
title Water reticulation model for Taman Maju, Parit Raja
title_full Water reticulation model for Taman Maju, Parit Raja
title_fullStr Water reticulation model for Taman Maju, Parit Raja
title_full_unstemmed Water reticulation model for Taman Maju, Parit Raja
title_short Water reticulation model for Taman Maju, Parit Raja
title_sort water reticulation model for taman maju, parit raja
topic TD Environmental technology. Sanitary engineering
TD481-493 Water distribution systems
url http://eprints.uthm.edu.my/2858/1/24p%20OTMAN%20MOHAMED%20O.%20ELOJALI.pdf
http://eprints.uthm.edu.my/2858/2/OTMAN%20MOHAMED%20O.%20ELOJALI%20COPYRIGHT%20DECLARATION.pdf
http://eprints.uthm.edu.my/2858/3/OTMAN%20MOHAMED%20O.%20ELOJALI%20WATERMARK.pdf
http://eprints.uthm.edu.my/2858/
url_provider http://eprints.uthm.edu.my/