Effect of field utilization factor on air breakdown level under impulse lightning in point-sphere electrode system

Nowadays, the high voltage power is very important to industries. Due to growing of technology, the power equipment also improves and innovates to have the best performance. The high voltage power equipment is mainly subjected to spark over voltage. Spark over can be useful in some cases and ma...

Full description

Saved in:
Bibliographic Details
Main Author: Abdullah @ Abdul Rahman, Suhaimi
Format: Thesis
Language:en
en
Published: 2014
Subjects:
Online Access:http://eprints.uthm.edu.my/1689/1/24p%20SUHAIMI%20ABDULLAH%40ABDUL%20RAHMAN.pdf
http://eprints.uthm.edu.my/1689/2/SUHAIMI%20ABDULLAH%40ABDUL%20RAHMAN%20WATERMARK.pdf
http://eprints.uthm.edu.my/1689/
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1833416870341902336
author Abdullah @ Abdul Rahman, Suhaimi
author_facet Abdullah @ Abdul Rahman, Suhaimi
author_sort Abdullah @ Abdul Rahman, Suhaimi
building UTHM Library
collection Institutional Repository
content_provider Universiti Tun Hussein Onn Malaysia
content_source UTHM Institutional Repository
continent Asia
country Malaysia
description Nowadays, the high voltage power is very important to industries. Due to growing of technology, the power equipment also improves and innovates to have the best performance. The high voltage power equipment is mainly subjected to spark over voltage. Spark over can be useful in some cases and may give bad effect or damage the machine. Therefore the research on the behavior of spark over, breakdown voltage is signified in the electrical engineering designing process. The project is started with an experimental setup to get the standard impulse voltage. This lightning impulse voltage is ensuring to follow the standard of BS EN 60060-1:2010. The procedure of this experiment follows the TERCO catalogue documentation. In this project, the standard point-sphere gap is use to measurements of U50 breakdown voltages. A metallic point electrode is separated by a certain distance form a sphere gap. Also, the gap length between the spheres will be varied from 1 cm to 3 cm. The procedure to get U50 is followed to Up and Down method. FEMM software is use for simulation and analysis of electric field distribution for point-sphere electrode. This software provides a wide range of simulation applications for controlling the complexity of both modelling and analysis of a system. The value of U50 obtained is used in this simulation. The characteristic of field intensity will be analysed for all gaps. The average of field intensity and field utilization factor F.U.F will be analysed by using this software
format Thesis
id my.uthm.eprints-1689
institution Universiti Tun Hussein Onn Malaysia
language en
en
publishDate 2014
record_format eprints
spelling my.uthm.eprints-16892021-10-04T08:39:46Z http://eprints.uthm.edu.my/1689/ Effect of field utilization factor on air breakdown level under impulse lightning in point-sphere electrode system Abdullah @ Abdul Rahman, Suhaimi TK Electrical engineering. Electronics Nuclear engineering TK2000-2891 Dynamoelectric machinery and auxiliaries. Including generators, motors, transformers Nowadays, the high voltage power is very important to industries. Due to growing of technology, the power equipment also improves and innovates to have the best performance. The high voltage power equipment is mainly subjected to spark over voltage. Spark over can be useful in some cases and may give bad effect or damage the machine. Therefore the research on the behavior of spark over, breakdown voltage is signified in the electrical engineering designing process. The project is started with an experimental setup to get the standard impulse voltage. This lightning impulse voltage is ensuring to follow the standard of BS EN 60060-1:2010. The procedure of this experiment follows the TERCO catalogue documentation. In this project, the standard point-sphere gap is use to measurements of U50 breakdown voltages. A metallic point electrode is separated by a certain distance form a sphere gap. Also, the gap length between the spheres will be varied from 1 cm to 3 cm. The procedure to get U50 is followed to Up and Down method. FEMM software is use for simulation and analysis of electric field distribution for point-sphere electrode. This software provides a wide range of simulation applications for controlling the complexity of both modelling and analysis of a system. The value of U50 obtained is used in this simulation. The characteristic of field intensity will be analysed for all gaps. The average of field intensity and field utilization factor F.U.F will be analysed by using this software 2014-07 Thesis NonPeerReviewed text en http://eprints.uthm.edu.my/1689/1/24p%20SUHAIMI%20ABDULLAH%40ABDUL%20RAHMAN.pdf text en http://eprints.uthm.edu.my/1689/2/SUHAIMI%20ABDULLAH%40ABDUL%20RAHMAN%20WATERMARK.pdf Abdullah @ Abdul Rahman, Suhaimi (2014) Effect of field utilization factor on air breakdown level under impulse lightning in point-sphere electrode system. Masters thesis, Universiti Tun Hussein Onn Malaysia.
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
TK2000-2891 Dynamoelectric machinery and auxiliaries. Including generators, motors, transformers
Abdullah @ Abdul Rahman, Suhaimi
Effect of field utilization factor on air breakdown level under impulse lightning in point-sphere electrode system
title Effect of field utilization factor on air breakdown level under impulse lightning in point-sphere electrode system
title_full Effect of field utilization factor on air breakdown level under impulse lightning in point-sphere electrode system
title_fullStr Effect of field utilization factor on air breakdown level under impulse lightning in point-sphere electrode system
title_full_unstemmed Effect of field utilization factor on air breakdown level under impulse lightning in point-sphere electrode system
title_short Effect of field utilization factor on air breakdown level under impulse lightning in point-sphere electrode system
title_sort effect of field utilization factor on air breakdown level under impulse lightning in point-sphere electrode system
topic TK Electrical engineering. Electronics Nuclear engineering
TK2000-2891 Dynamoelectric machinery and auxiliaries. Including generators, motors, transformers
url http://eprints.uthm.edu.my/1689/1/24p%20SUHAIMI%20ABDULLAH%40ABDUL%20RAHMAN.pdf
http://eprints.uthm.edu.my/1689/2/SUHAIMI%20ABDULLAH%40ABDUL%20RAHMAN%20WATERMARK.pdf
http://eprints.uthm.edu.my/1689/
url_provider http://eprints.uthm.edu.my/