Performance assessment of large‑scale rooftop solar PV system: a case study in a Malaysian Public University

Adopting rooftop solar PV systems in various domestic and non-domestic sectors (including commercial, industrial, and agricultural) exhibits their commitment to green energy ventures. This study intends to evaluate the efectiveness of a grid-connected solar system that has been installed so far: a 6...

Full description

Saved in:
Bibliographic Details
Main Authors: Govindarajan, Logeswaran, Mohideen Batcha, Mohd Faizal, Abdullah, Mohammad Kamil
Format: Article
Language:en
Published: Discovery 2024
Subjects:
Online Access:http://eprints.uthm.edu.my/12525/1/J18013_b77aaad567955261e3fd90cf39be3415.pdf
http://eprints.uthm.edu.my/12525/
https://doi.org/10.1007/s42452-024-06007-9
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1833419812378771456
author Govindarajan, Logeswaran
Mohideen Batcha, Mohd Faizal
Abdullah, Mohammad Kamil
author_facet Govindarajan, Logeswaran
Mohideen Batcha, Mohd Faizal
Abdullah, Mohammad Kamil
author_sort Govindarajan, Logeswaran
building UTHM Library
collection Institutional Repository
content_provider Universiti Tun Hussein Onn Malaysia
content_source UTHM Institutional Repository
continent Asia
country Malaysia
description Adopting rooftop solar PV systems in various domestic and non-domestic sectors (including commercial, industrial, and agricultural) exhibits their commitment to green energy ventures. This study intends to evaluate the efectiveness of a grid-connected solar system that has been installed so far: a 6.9 MWp photovoltaic (PV) system implemented at University Tun Hussein Onn (UTHM) in Batu Pahat, Johor. This green energy system was installed as a part of the Self-Consumption (SELCO) program utilizing a Supply Agreement for Renewable Energy (SARE) contract. To assess the mounted energy system’s efciency, performance monitoring was carried out between December 2021 and November 2022. By evaluating the enactment of the 6.9 MWp solar system at UTHM, this present work has attempted to compile the achievement of implementation of self-consumption in terms of performance analysis and fnancial benefts to consumer. Based on International Electrotechnical Commission (IEC) 61724 standard, this study also investigates several performance characteristics of the PV system, such as fnal yield, clearness index (CI), array yield, PV module efciency, inverter efciency, reference yield, and capacity factor (CF) performance ratio (PR). Moreover, an assessment of Carbon Dioxide (CO2) avoidance was also conducted to quantify the amount of CO2 reduction achieved. In addition, the self-consumption ratio and self-sufciency ratio pattern for solar power plant in UTHM has been assessed. The monthly clearness index at the project location from December 2021 to November 2022 ranges from 0.63 to 0.66. The PV system was monitored throughout this time and generated 8529 MWh of energy. The installed PV system has shown an efciency of 11.86%, a fnal yield of 108.28%, and a PR of 0.78, respectively. Further, the installed 6.9 MWp PV system at UTHM will cut CO2 emissions by 5450 tons annually. The 6.9 MWp solar PV system is also estimated to reduce 25.1 RM mil in 25 years. Making the system larger to 6.9 MWp would reduce the consumption from the grid during the week, makes it possible to achieve self-consumption levels of up to 100% and self-sufciency of this solar plant is relatively low ranges from 22 to 35%. The research fnding bridges the gap between policy makers, investors, and the public regarding acceptance of the large-scale Self-Consumption (SELCO) and strengthen the strategic collaborations between solar service provider and educational bodies to support of the government’s agenda to achieve carbon emission intensity reduction in Malaysia.
format Article
id my.uthm.eprints-12525
institution Universiti Tun Hussein Onn Malaysia
language en
publishDate 2024
publisher Discovery
record_format eprints
spelling my.uthm.eprints-125252025-03-19T01:08:55Z http://eprints.uthm.edu.my/12525/ Performance assessment of large‑scale rooftop solar PV system: a case study in a Malaysian Public University Govindarajan, Logeswaran Mohideen Batcha, Mohd Faizal Abdullah, Mohammad Kamil TK Electrical engineering. Electronics Nuclear engineering Adopting rooftop solar PV systems in various domestic and non-domestic sectors (including commercial, industrial, and agricultural) exhibits their commitment to green energy ventures. This study intends to evaluate the efectiveness of a grid-connected solar system that has been installed so far: a 6.9 MWp photovoltaic (PV) system implemented at University Tun Hussein Onn (UTHM) in Batu Pahat, Johor. This green energy system was installed as a part of the Self-Consumption (SELCO) program utilizing a Supply Agreement for Renewable Energy (SARE) contract. To assess the mounted energy system’s efciency, performance monitoring was carried out between December 2021 and November 2022. By evaluating the enactment of the 6.9 MWp solar system at UTHM, this present work has attempted to compile the achievement of implementation of self-consumption in terms of performance analysis and fnancial benefts to consumer. Based on International Electrotechnical Commission (IEC) 61724 standard, this study also investigates several performance characteristics of the PV system, such as fnal yield, clearness index (CI), array yield, PV module efciency, inverter efciency, reference yield, and capacity factor (CF) performance ratio (PR). Moreover, an assessment of Carbon Dioxide (CO2) avoidance was also conducted to quantify the amount of CO2 reduction achieved. In addition, the self-consumption ratio and self-sufciency ratio pattern for solar power plant in UTHM has been assessed. The monthly clearness index at the project location from December 2021 to November 2022 ranges from 0.63 to 0.66. The PV system was monitored throughout this time and generated 8529 MWh of energy. The installed PV system has shown an efciency of 11.86%, a fnal yield of 108.28%, and a PR of 0.78, respectively. Further, the installed 6.9 MWp PV system at UTHM will cut CO2 emissions by 5450 tons annually. The 6.9 MWp solar PV system is also estimated to reduce 25.1 RM mil in 25 years. Making the system larger to 6.9 MWp would reduce the consumption from the grid during the week, makes it possible to achieve self-consumption levels of up to 100% and self-sufciency of this solar plant is relatively low ranges from 22 to 35%. The research fnding bridges the gap between policy makers, investors, and the public regarding acceptance of the large-scale Self-Consumption (SELCO) and strengthen the strategic collaborations between solar service provider and educational bodies to support of the government’s agenda to achieve carbon emission intensity reduction in Malaysia. Discovery 2024 Article PeerReviewed text en http://eprints.uthm.edu.my/12525/1/J18013_b77aaad567955261e3fd90cf39be3415.pdf Govindarajan, Logeswaran and Mohideen Batcha, Mohd Faizal and Abdullah, Mohammad Kamil (2024) Performance assessment of large‑scale rooftop solar PV system: a case study in a Malaysian Public University. Discover Applied Sciences, 6 (328). pp. 1-26. https://doi.org/10.1007/s42452-024-06007-9
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Govindarajan, Logeswaran
Mohideen Batcha, Mohd Faizal
Abdullah, Mohammad Kamil
Performance assessment of large‑scale rooftop solar PV system: a case study in a Malaysian Public University
title Performance assessment of large‑scale rooftop solar PV system: a case study in a Malaysian Public University
title_full Performance assessment of large‑scale rooftop solar PV system: a case study in a Malaysian Public University
title_fullStr Performance assessment of large‑scale rooftop solar PV system: a case study in a Malaysian Public University
title_full_unstemmed Performance assessment of large‑scale rooftop solar PV system: a case study in a Malaysian Public University
title_short Performance assessment of large‑scale rooftop solar PV system: a case study in a Malaysian Public University
title_sort performance assessment of large‑scale rooftop solar pv system: a case study in a malaysian public university
topic TK Electrical engineering. Electronics Nuclear engineering
url http://eprints.uthm.edu.my/12525/1/J18013_b77aaad567955261e3fd90cf39be3415.pdf
http://eprints.uthm.edu.my/12525/
https://doi.org/10.1007/s42452-024-06007-9
url_provider http://eprints.uthm.edu.my/