Monitoring of Outdoor and Indoor Air Particulate Matter (PM10) at Buildings Located in An Industrial District

Particulate matter (PM10) pollution has become a problem of significant impact in many countries and cities due to its dangerous effects on public health and environmental balance. The current study aims to monitor the indoor and outdoor PM10 concentrations of the buildings located next to an indust...

Full description

Saved in:
Bibliographic Details
Main Authors: Al-Sahari, Mohammed, Al-Gheethi, Adel, Siti Zaidah, Siti Zaidah, Saphira, Radin Maya, Al Madhoun, Wesam, Anaam, Ahmed Abdulmalek
Format: Article
Language:en
Published: uthm 2023
Subjects:
Online Access:http://eprints.uthm.edu.my/11629/1/J16141_7d6b8e69ee6b45e3627aeccb5f746272.pdf
http://eprints.uthm.edu.my/11629/
https://doi.org/10.30880/ijscet.2023.14.02.024
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1833419574902521856
author Al-Sahari, Mohammed
Al-Gheethi, Adel
Siti Zaidah, Siti Zaidah
Saphira, Radin Maya
Al Madhoun, Wesam
Anaam, Ahmed Abdulmalek
author_facet Al-Sahari, Mohammed
Al-Gheethi, Adel
Siti Zaidah, Siti Zaidah
Saphira, Radin Maya
Al Madhoun, Wesam
Anaam, Ahmed Abdulmalek
author_sort Al-Sahari, Mohammed
building UTHM Library
collection Institutional Repository
content_provider Universiti Tun Hussein Onn Malaysia
content_source UTHM Institutional Repository
continent Asia
country Malaysia
description Particulate matter (PM10) pollution has become a problem of significant impact in many countries and cities due to its dangerous effects on public health and environmental balance. The current study aims to monitor the indoor and outdoor PM10 concentrations of the buildings located next to an industrial area that releasing industrial fumes. Three buildings were selected to be investigated. Two factors were considered in the current study, including the outdoor PM10 and wind speed. Response surface methodology (RSM) design was used to identify the relationship between the outdoor and indoor PM10 concentration (I/O) through the ANOVA analysis (P<0.05). The obtained results of PM10 concentrations were showed an acceptable concentration (PM10.In.max= 34 µg.m-3, PM10.Out.max= 77 µg.m-3) compared to the Malaysian standard of Practice (DOSH) and RMAAQG (150 µg.m-3) for the selected areas. The investigation was showed a relationship between PM10.in, PM10.out, and the wind speed with a significant ANOVA factor (P < 0.05). The study findings are considered a knowledge contribution of the PM10 concentrations on the relationship of indoor and outdoor air quality for building surrounded by factories.
format Article
id my.uthm.eprints-11629
institution Universiti Tun Hussein Onn Malaysia
language en
publishDate 2023
publisher uthm
record_format eprints
spelling my.uthm.eprints-116292024-09-25T07:23:58Z http://eprints.uthm.edu.my/11629/ Monitoring of Outdoor and Indoor Air Particulate Matter (PM10) at Buildings Located in An Industrial District Al-Sahari, Mohammed Al-Gheethi, Adel Siti Zaidah, Siti Zaidah Saphira, Radin Maya Al Madhoun, Wesam Anaam, Ahmed Abdulmalek T Technology (General) Particulate matter (PM10) pollution has become a problem of significant impact in many countries and cities due to its dangerous effects on public health and environmental balance. The current study aims to monitor the indoor and outdoor PM10 concentrations of the buildings located next to an industrial area that releasing industrial fumes. Three buildings were selected to be investigated. Two factors were considered in the current study, including the outdoor PM10 and wind speed. Response surface methodology (RSM) design was used to identify the relationship between the outdoor and indoor PM10 concentration (I/O) through the ANOVA analysis (P<0.05). The obtained results of PM10 concentrations were showed an acceptable concentration (PM10.In.max= 34 µg.m-3, PM10.Out.max= 77 µg.m-3) compared to the Malaysian standard of Practice (DOSH) and RMAAQG (150 µg.m-3) for the selected areas. The investigation was showed a relationship between PM10.in, PM10.out, and the wind speed with a significant ANOVA factor (P < 0.05). The study findings are considered a knowledge contribution of the PM10 concentrations on the relationship of indoor and outdoor air quality for building surrounded by factories. uthm 2023 Article PeerReviewed text en http://eprints.uthm.edu.my/11629/1/J16141_7d6b8e69ee6b45e3627aeccb5f746272.pdf Al-Sahari, Mohammed and Al-Gheethi, Adel and Siti Zaidah, Siti Zaidah and Saphira, Radin Maya and Al Madhoun, Wesam and Anaam, Ahmed Abdulmalek (2023) Monitoring of Outdoor and Indoor Air Particulate Matter (PM10) at Buildings Located in An Industrial District. INTERNATIONAL JOURNAL OF SUSTAINABLE CONSTRUCTION ENGINEERING AND TECHNOLOGY, 14 (2). pp. 232-239. ISSN 2180-3242 https://doi.org/10.30880/ijscet.2023.14.02.024
spellingShingle T Technology (General)
Al-Sahari, Mohammed
Al-Gheethi, Adel
Siti Zaidah, Siti Zaidah
Saphira, Radin Maya
Al Madhoun, Wesam
Anaam, Ahmed Abdulmalek
Monitoring of Outdoor and Indoor Air Particulate Matter (PM10) at Buildings Located in An Industrial District
title Monitoring of Outdoor and Indoor Air Particulate Matter (PM10) at Buildings Located in An Industrial District
title_full Monitoring of Outdoor and Indoor Air Particulate Matter (PM10) at Buildings Located in An Industrial District
title_fullStr Monitoring of Outdoor and Indoor Air Particulate Matter (PM10) at Buildings Located in An Industrial District
title_full_unstemmed Monitoring of Outdoor and Indoor Air Particulate Matter (PM10) at Buildings Located in An Industrial District
title_short Monitoring of Outdoor and Indoor Air Particulate Matter (PM10) at Buildings Located in An Industrial District
title_sort monitoring of outdoor and indoor air particulate matter (pm10) at buildings located in an industrial district
topic T Technology (General)
url http://eprints.uthm.edu.my/11629/1/J16141_7d6b8e69ee6b45e3627aeccb5f746272.pdf
http://eprints.uthm.edu.my/11629/
https://doi.org/10.30880/ijscet.2023.14.02.024
url_provider http://eprints.uthm.edu.my/