Permanent magnet flux switching torque performance indicator

Flux switching machine (FSM) offer advantages such as rotor robustness and simple driving circuit compared to competing machine. This paper attempts to process the torque, volume and current information from 35 latest Permanent Magnet (PM) FSM publication into a standardized Torque Performance I...

Full description

Saved in:
Bibliographic Details
Main Authors: Mohd Ab Halim, Mohd Firdaus, Sulaiman, Erwan
Format: Article
Language:en
Published: TUBITAK 2021
Online Access:http://eprints.utem.edu.my/id/eprint/26134/2/FLUX_SWITCHING_MACHINE.PDF
http://eprints.utem.edu.my/id/eprint/26134/
https://dergipark.org.tr/tr/pub/ecjse/issue/62605/842739
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Flux switching machine (FSM) offer advantages such as rotor robustness and simple driving circuit compared to competing machine. This paper attempts to process the torque, volume and current information from 35 latest Permanent Magnet (PM) FSM publication into a standardized Torque Performance Indicator (TPI), which are torque density, torque constant, torque constant density and torque-magnet ratio. The distribution median shows that torque density, torque constant, torque constant density and torque-magnet ratio are 23.24kNm/m3, 0.43Nm/A, 0.616Nkm/Am3 and 30.79Nm/kg respectively. Among many design variation, outer rotor configuration produces good values as overall in the TPI. This information can be used to guide the machine designer to compare and compete based on the standardized TPI.