Comparative study of different PWM control scheme for three-phase three-wire shunt active power filter

Instantaneous reactive power theory was the most popular control theory used when dealing with harmonics compensations. In conjunction with the instantaneous theory, switching signal generation techniques plays an important role to ensure the correct compensation signal injected in the system. Th...

Full description

Saved in:
Bibliographic Details
Main Authors: A.S.A. , Hasim, Zulkifilie, Ibrahim, Hairul Nizam, Talib
Format: Conference or Workshop Item
Language:en
Published: 2012
Subjects:
Online Access:http://eprints.utem.edu.my/id/eprint/15111/1/Comparative%20study%20of%20different%20PWM%20control%20scheme%20for%20three-phase%20three-wire%20shunt%20active%20power%20filter195.pdf
http://eprints.utem.edu.my/id/eprint/15111/
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832717039404318720
author A.S.A. , Hasim
Zulkifilie, Ibrahim
Hairul Nizam, Talib
author_facet A.S.A. , Hasim
Zulkifilie, Ibrahim
Hairul Nizam, Talib
author_sort A.S.A. , Hasim
building UTEM Library
collection Institutional Repository
content_provider Universiti Teknikal Malaysia Melaka
content_source UTEM Institutional Repository
continent Asia
country Malaysia
description Instantaneous reactive power theory was the most popular control theory used when dealing with harmonics compensations. In conjunction with the instantaneous theory, switching signal generation techniques plays an important role to ensure the correct compensation signal injected in the system. Therefore, this paper discussed on comparative study of five (5) methods used in instantaneous theory namely; p-q method, modified p-q, d-q method, p-q-r method and vectorial with three (3) types. of signal generation namely; carrier current control, hysteresis current control and space vector modulation control. Continuous reductions of the total harmonics distortion (THD) are expected at the supply current when applied different types of switching technique. The compnrison was examining using MATLAB/Sirnulink (MLS) environment.
format Conference or Workshop Item
id my.utem.eprints-15111
institution Universiti Teknikal Malaysia Melaka
language en
publishDate 2012
record_format eprints
spelling my.utem.eprints-151112015-10-27T01:58:09Z http://eprints.utem.edu.my/id/eprint/15111/ Comparative study of different PWM control scheme for three-phase three-wire shunt active power filter A.S.A. , Hasim Zulkifilie, Ibrahim Hairul Nizam, Talib TK Electrical engineering. Electronics Nuclear engineering Instantaneous reactive power theory was the most popular control theory used when dealing with harmonics compensations. In conjunction with the instantaneous theory, switching signal generation techniques plays an important role to ensure the correct compensation signal injected in the system. Therefore, this paper discussed on comparative study of five (5) methods used in instantaneous theory namely; p-q method, modified p-q, d-q method, p-q-r method and vectorial with three (3) types. of signal generation namely; carrier current control, hysteresis current control and space vector modulation control. Continuous reductions of the total harmonics distortion (THD) are expected at the supply current when applied different types of switching technique. The compnrison was examining using MATLAB/Sirnulink (MLS) environment. 2012 Conference or Workshop Item PeerReviewed text en http://eprints.utem.edu.my/id/eprint/15111/1/Comparative%20study%20of%20different%20PWM%20control%20scheme%20for%20three-phase%20three-wire%20shunt%20active%20power%20filter195.pdf A.S.A. , Hasim and Zulkifilie, Ibrahim and Hairul Nizam, Talib (2012) Comparative study of different PWM control scheme for three-phase three-wire shunt active power filter. In: IEEE International Power Engineering and Optimization Conference (PEDCO), 6-7 June 2012, Melaka, Malaysia. (Submitted)
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
A.S.A. , Hasim
Zulkifilie, Ibrahim
Hairul Nizam, Talib
Comparative study of different PWM control scheme for three-phase three-wire shunt active power filter
title Comparative study of different PWM control scheme for three-phase three-wire shunt active power filter
title_full Comparative study of different PWM control scheme for three-phase three-wire shunt active power filter
title_fullStr Comparative study of different PWM control scheme for three-phase three-wire shunt active power filter
title_full_unstemmed Comparative study of different PWM control scheme for three-phase three-wire shunt active power filter
title_short Comparative study of different PWM control scheme for three-phase three-wire shunt active power filter
title_sort comparative study of different pwm control scheme for three-phase three-wire shunt active power filter
topic TK Electrical engineering. Electronics Nuclear engineering
url http://eprints.utem.edu.my/id/eprint/15111/1/Comparative%20study%20of%20different%20PWM%20control%20scheme%20for%20three-phase%20three-wire%20shunt%20active%20power%20filter195.pdf
http://eprints.utem.edu.my/id/eprint/15111/
url_provider http://eprints.utem.edu.my/