EBT2 film dosimetry using Imaged software analysis in comparison to Verisoft software at High Energy Electron Beam

This study was conducted, to compare ImageJ and Verisoft softwares in EBT2 Gafchromic film dosimetry in High Energy Electron Beam. Film was cut into 3 cm x 3 cm dimension. 6 MeV and 9MeV energy use under Siemens Primus (LINAC), for calibration purpose, the film was exposed to dose 0 cGy to 600 cGy...

Full description

Saved in:
Bibliographic Details
Main Author: Yusop, Mohd Fahrizuan Md
Format: Monograph
Language:en
Published: Universiti Sains Malaysia 2016
Subjects:
Online Access:http://eprints.usm.my/62721/1/MOHD%20FAHRIZUAN%20BIN%20MD%20YUSOP%20-%20e.pdf
http://eprints.usm.my/62721/
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1842850775525490688
author Yusop, Mohd Fahrizuan Md
author_facet Yusop, Mohd Fahrizuan Md
author_sort Yusop, Mohd Fahrizuan Md
building Hamzah Sendut Library
collection Institutional Repository
content_provider Universiti Sains Malaysia
content_source USM Institutional Repository
continent Asia
country Malaysia
description This study was conducted, to compare ImageJ and Verisoft softwares in EBT2 Gafchromic film dosimetry in High Energy Electron Beam. Film was cut into 3 cm x 3 cm dimension. 6 MeV and 9MeV energy use under Siemens Primus (LINAC), for calibration purpose, the film was exposed to dose 0 cGy to 600 cGy and for measuring FDD and beam profile, another film was irradiated with 400MU monitor unit. The irradiated films were scanned with Epson Expression 10 000XL flatbed scanner. The percentage depth dose (PDD) and beam profile of 6 MeV and 9 MeV electron beams were analyzed by using ImageJ and Verisoft software. Result of this study shows, the discrepancy (% of error) of ImageJ towards Verisoft for all depth are 4.05 % and discrepancy (% of error) comparison between ImageJ software with Ionization Chamber reading are 29.4 %. The highest beam flatness of Verisoft and ImageJ software are 5.88 % and 8 % respectively, the highest penumbra size for Verisoft and ImageJ software are 4 cm both. In conclusions, ImageJ software can be use as software in electron beam dosimetric analysis since it has less percent of error compare to Verisoft software and Ionization Chamber reading.
format Monograph
id my.usm.eprints.62721
institution Universiti Sains Malaysia
language en
publishDate 2016
publisher Universiti Sains Malaysia
record_format eprints
spelling my.usm.eprints.62721 http://eprints.usm.my/62721/ EBT2 film dosimetry using Imaged software analysis in comparison to Verisoft software at High Energy Electron Beam Yusop, Mohd Fahrizuan Md R Medicine (General) RA Public aspects of medicine This study was conducted, to compare ImageJ and Verisoft softwares in EBT2 Gafchromic film dosimetry in High Energy Electron Beam. Film was cut into 3 cm x 3 cm dimension. 6 MeV and 9MeV energy use under Siemens Primus (LINAC), for calibration purpose, the film was exposed to dose 0 cGy to 600 cGy and for measuring FDD and beam profile, another film was irradiated with 400MU monitor unit. The irradiated films were scanned with Epson Expression 10 000XL flatbed scanner. The percentage depth dose (PDD) and beam profile of 6 MeV and 9 MeV electron beams were analyzed by using ImageJ and Verisoft software. Result of this study shows, the discrepancy (% of error) of ImageJ towards Verisoft for all depth are 4.05 % and discrepancy (% of error) comparison between ImageJ software with Ionization Chamber reading are 29.4 %. The highest beam flatness of Verisoft and ImageJ software are 5.88 % and 8 % respectively, the highest penumbra size for Verisoft and ImageJ software are 4 cm both. In conclusions, ImageJ software can be use as software in electron beam dosimetric analysis since it has less percent of error compare to Verisoft software and Ionization Chamber reading. Universiti Sains Malaysia 2016 Monograph NonPeerReviewed application/pdf en http://eprints.usm.my/62721/1/MOHD%20FAHRIZUAN%20BIN%20MD%20YUSOP%20-%20e.pdf Yusop, Mohd Fahrizuan Md (2016) EBT2 film dosimetry using Imaged software analysis in comparison to Verisoft software at High Energy Electron Beam. Project Report. Universiti Sains Malaysia. (Submitted)
spellingShingle R Medicine (General)
RA Public aspects of medicine
Yusop, Mohd Fahrizuan Md
EBT2 film dosimetry using Imaged software analysis in comparison to Verisoft software at High Energy Electron Beam
title EBT2 film dosimetry using Imaged software analysis in comparison to Verisoft software at High Energy Electron Beam
title_full EBT2 film dosimetry using Imaged software analysis in comparison to Verisoft software at High Energy Electron Beam
title_fullStr EBT2 film dosimetry using Imaged software analysis in comparison to Verisoft software at High Energy Electron Beam
title_full_unstemmed EBT2 film dosimetry using Imaged software analysis in comparison to Verisoft software at High Energy Electron Beam
title_short EBT2 film dosimetry using Imaged software analysis in comparison to Verisoft software at High Energy Electron Beam
title_sort ebt2 film dosimetry using imaged software analysis in comparison to verisoft software at high energy electron beam
topic R Medicine (General)
RA Public aspects of medicine
url http://eprints.usm.my/62721/1/MOHD%20FAHRIZUAN%20BIN%20MD%20YUSOP%20-%20e.pdf
http://eprints.usm.my/62721/
url_provider http://eprints.usm.my/