Determination of diagnostic reference levels (drls) for digital radiography (abdomen & pelvic examinations) in Hospital Universiti Sains Malaysia (HUSM)

The aim of this study is measurement the diagnostic reference levels (DRLs) for digital radiography (abdomen & pelvic examinations) in Hospital USM. This study is the estimation of the entrance surface dose (ESD) delivered to patients. ESD can be measured directly by using Thermoluminescence...

Full description

Saved in:
Bibliographic Details
Main Author: Zain, Shafirah Mohd
Format: Monograph
Language:en
Published: Universiti Sains Malaysia 2016
Subjects:
Online Access:http://eprints.usm.my/62390/1/SHAFIRAH%20BINTI%20MOHD%20ZAIN%20-%20e.pdf
http://eprints.usm.my/62390/
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1836858724002562048
author Zain, Shafirah Mohd
author_facet Zain, Shafirah Mohd
author_sort Zain, Shafirah Mohd
building Hamzah Sendut Library
collection Institutional Repository
content_provider Universiti Sains Malaysia
content_source USM Institutional Repository
continent Asia
country Malaysia
description The aim of this study is measurement the diagnostic reference levels (DRLs) for digital radiography (abdomen & pelvic examinations) in Hospital USM. This study is the estimation of the entrance surface dose (ESD) delivered to patients. ESD can be measured directly by using Thermoluminescence Dosimeter (TLD) which is LiF: Mg,Cu,P (TLD 100H). The examination involved 30 patients for each procedures of abdomen (AP) and pelvic (AP). The participants involved in range 18 years old and above, weight between 35 to 100 kg, and both male and female are included. The ESD were measured directly with TLD 100H that mounted on tape and placed at the centre x-ray beam on patient skin. The DRLs value found in Hospital USM were compared to DRLs stated by national and international. Hospital USM third quartile of ESDs value estimated for abdomen is 3.75 mGy and pelvic is 2.75 mGy. This result indicate that the ESD received by patients were to be lowered than or in acceptance range with the guidance level set by the national, IAEA and other international country. One possible reason is that the patient size is relatively smaller than a European patient. It is also possible that x-ray machine at Hospital USM was well maintained and have pass all the annual Quality Assurance evaluations before being operate. Consequently, the radiation risk to patients is minimized and will help in optimization radiation protection of patient. Overall it was found this result will be useful for the formulation of reference in HUSM as recommended by the IAEA.
format Monograph
id my.usm.eprints.62390
institution Universiti Sains Malaysia
language en
publishDate 2016
publisher Universiti Sains Malaysia
record_format eprints
spelling my.usm.eprints.62390 http://eprints.usm.my/62390/ Determination of diagnostic reference levels (drls) for digital radiography (abdomen & pelvic examinations) in Hospital Universiti Sains Malaysia (HUSM) Zain, Shafirah Mohd R Medicine (General) RC71-78.7 Examination. Diagnosis Including raiography The aim of this study is measurement the diagnostic reference levels (DRLs) for digital radiography (abdomen & pelvic examinations) in Hospital USM. This study is the estimation of the entrance surface dose (ESD) delivered to patients. ESD can be measured directly by using Thermoluminescence Dosimeter (TLD) which is LiF: Mg,Cu,P (TLD 100H). The examination involved 30 patients for each procedures of abdomen (AP) and pelvic (AP). The participants involved in range 18 years old and above, weight between 35 to 100 kg, and both male and female are included. The ESD were measured directly with TLD 100H that mounted on tape and placed at the centre x-ray beam on patient skin. The DRLs value found in Hospital USM were compared to DRLs stated by national and international. Hospital USM third quartile of ESDs value estimated for abdomen is 3.75 mGy and pelvic is 2.75 mGy. This result indicate that the ESD received by patients were to be lowered than or in acceptance range with the guidance level set by the national, IAEA and other international country. One possible reason is that the patient size is relatively smaller than a European patient. It is also possible that x-ray machine at Hospital USM was well maintained and have pass all the annual Quality Assurance evaluations before being operate. Consequently, the radiation risk to patients is minimized and will help in optimization radiation protection of patient. Overall it was found this result will be useful for the formulation of reference in HUSM as recommended by the IAEA. Universiti Sains Malaysia 2016 Monograph NonPeerReviewed application/pdf en http://eprints.usm.my/62390/1/SHAFIRAH%20BINTI%20MOHD%20ZAIN%20-%20e.pdf Zain, Shafirah Mohd (2016) Determination of diagnostic reference levels (drls) for digital radiography (abdomen & pelvic examinations) in Hospital Universiti Sains Malaysia (HUSM). Project Report. Universiti Sains Malaysia. (Submitted)
spellingShingle R Medicine (General)
RC71-78.7 Examination. Diagnosis Including raiography
Zain, Shafirah Mohd
Determination of diagnostic reference levels (drls) for digital radiography (abdomen & pelvic examinations) in Hospital Universiti Sains Malaysia (HUSM)
title Determination of diagnostic reference levels (drls) for digital radiography (abdomen & pelvic examinations) in Hospital Universiti Sains Malaysia (HUSM)
title_full Determination of diagnostic reference levels (drls) for digital radiography (abdomen & pelvic examinations) in Hospital Universiti Sains Malaysia (HUSM)
title_fullStr Determination of diagnostic reference levels (drls) for digital radiography (abdomen & pelvic examinations) in Hospital Universiti Sains Malaysia (HUSM)
title_full_unstemmed Determination of diagnostic reference levels (drls) for digital radiography (abdomen & pelvic examinations) in Hospital Universiti Sains Malaysia (HUSM)
title_short Determination of diagnostic reference levels (drls) for digital radiography (abdomen & pelvic examinations) in Hospital Universiti Sains Malaysia (HUSM)
title_sort determination of diagnostic reference levels (drls) for digital radiography (abdomen & pelvic examinations) in hospital universiti sains malaysia (husm)
topic R Medicine (General)
RC71-78.7 Examination. Diagnosis Including raiography
url http://eprints.usm.my/62390/1/SHAFIRAH%20BINTI%20MOHD%20ZAIN%20-%20e.pdf
http://eprints.usm.my/62390/
url_provider http://eprints.usm.my/