Semi-Automatic Features Extraction Of Cervical Cells

This project is entitled ‘Semi-automatic Features Extraction of Cervical Cells’. The project is aimed to create a user friendly software which can be able to analyze Pap smear images via image processing. Cytological screening using the Pap smear test is the most effective strategy for the det...

Full description

Saved in:
Bibliographic Details
Main Author: Mohanadas, Veerayen
Format: Monograph
Language:en
Published: Universiti Sains Malaysia 2005
Subjects:
Online Access:http://eprints.usm.my/57982/1/Semi-Automatic%20Features%20Extraction%20Of%20Cervical%20Cells_Veerayen%20Mohanadas.pdf
http://eprints.usm.my/57982/
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1834506700289212416
author Mohanadas, Veerayen
author_facet Mohanadas, Veerayen
author_sort Mohanadas, Veerayen
building Hamzah Sendut Library
collection Institutional Repository
content_provider Universiti Sains Malaysia
content_source USM Institutional Repository
continent Asia
country Malaysia
description This project is entitled ‘Semi-automatic Features Extraction of Cervical Cells’. The project is aimed to create a user friendly software which can be able to analyze Pap smear images via image processing. Cytological screening using the Pap smear test is the most effective strategy for the detection of precancerous state and consequent control of cervical cancer. Cytological samples that are taken from Pap smear test will undergo further analysis to detect the degree of abnormality of the cervical cells. The results of the abnormality of the samples can be inaccurate since some types of the medical images are blurring and highly affected by unwanted noise. Those bottlenecks in the medical images are believed that can be reduced via implementations of an adaptive fuzzy c-means (AFCM) and moving k-means (MKM) clustering techniques. These clustering techniques were used to segment the Pap smear images and later the features of the cells were extracted using region growing based feature extraction (RGBFE) technique. The performance of AFCM and MKM were analyzed based on the segmentation results of 6 Pap smear images. In overall, MKM was produced much better images than AFCM. Although the results have revealed that AFCM was suffering from centre redundancy and poor final centres in most of the cases, but it has also shown an advantage over MKM where AFCM was not sensitive to initial centres.
format Monograph
id my.usm.eprints.57982
institution Universiti Sains Malaysia
language en
publishDate 2005
publisher Universiti Sains Malaysia
record_format eprints
spelling my.usm.eprints.57982 http://eprints.usm.my/57982/ Semi-Automatic Features Extraction Of Cervical Cells Mohanadas, Veerayen T Technology TK Electrical Engineering. Electronics. Nuclear Engineering This project is entitled ‘Semi-automatic Features Extraction of Cervical Cells’. The project is aimed to create a user friendly software which can be able to analyze Pap smear images via image processing. Cytological screening using the Pap smear test is the most effective strategy for the detection of precancerous state and consequent control of cervical cancer. Cytological samples that are taken from Pap smear test will undergo further analysis to detect the degree of abnormality of the cervical cells. The results of the abnormality of the samples can be inaccurate since some types of the medical images are blurring and highly affected by unwanted noise. Those bottlenecks in the medical images are believed that can be reduced via implementations of an adaptive fuzzy c-means (AFCM) and moving k-means (MKM) clustering techniques. These clustering techniques were used to segment the Pap smear images and later the features of the cells were extracted using region growing based feature extraction (RGBFE) technique. The performance of AFCM and MKM were analyzed based on the segmentation results of 6 Pap smear images. In overall, MKM was produced much better images than AFCM. Although the results have revealed that AFCM was suffering from centre redundancy and poor final centres in most of the cases, but it has also shown an advantage over MKM where AFCM was not sensitive to initial centres. Universiti Sains Malaysia 2005-03-01 Monograph NonPeerReviewed application/pdf en http://eprints.usm.my/57982/1/Semi-Automatic%20Features%20Extraction%20Of%20Cervical%20Cells_Veerayen%20Mohanadas.pdf Mohanadas, Veerayen (2005) Semi-Automatic Features Extraction Of Cervical Cells. Project Report. Universiti Sains Malaysia, Pusat Pengajian Kejuruteraan Elektrik dan Elektronik. (Submitted)
spellingShingle T Technology
TK Electrical Engineering. Electronics. Nuclear Engineering
Mohanadas, Veerayen
Semi-Automatic Features Extraction Of Cervical Cells
title Semi-Automatic Features Extraction Of Cervical Cells
title_full Semi-Automatic Features Extraction Of Cervical Cells
title_fullStr Semi-Automatic Features Extraction Of Cervical Cells
title_full_unstemmed Semi-Automatic Features Extraction Of Cervical Cells
title_short Semi-Automatic Features Extraction Of Cervical Cells
title_sort semi-automatic features extraction of cervical cells
topic T Technology
TK Electrical Engineering. Electronics. Nuclear Engineering
url http://eprints.usm.my/57982/1/Semi-Automatic%20Features%20Extraction%20Of%20Cervical%20Cells_Veerayen%20Mohanadas.pdf
http://eprints.usm.my/57982/
url_provider http://eprints.usm.my/