Optimum Electrical Capacitance Tomography Sensor For Oil-Height Determination

There are two types of tomography systems, medical tomography and process tomography. ECT is one of the branches of process tomography. ECT or Electrical Capacitance Tomography is one of the techniques to measure the internal spatial distribution of materials. This new and very detailed knowle...

Full description

Saved in:
Bibliographic Details
Main Author: Hamzah, Muhamed Sufian
Format: Monograph
Language:en
Published: Universiti Sains Malaysia 2005
Subjects:
Online Access:http://eprints.usm.my/57793/1/Optimum%20Electrical%20Capacitance%20Tomography%20Sensor%20For%20Oil-Height%20Determination_Muhamed%20Sufian%20Hamzah.pdf
http://eprints.usm.my/57793/
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1834506648112070656
author Hamzah, Muhamed Sufian
author_facet Hamzah, Muhamed Sufian
author_sort Hamzah, Muhamed Sufian
building Hamzah Sendut Library
collection Institutional Repository
content_provider Universiti Sains Malaysia
content_source USM Institutional Repository
continent Asia
country Malaysia
description There are two types of tomography systems, medical tomography and process tomography. ECT is one of the branches of process tomography. ECT or Electrical Capacitance Tomography is one of the techniques to measure the internal spatial distribution of materials. This new and very detailed knowledge allows improved design of process equipment. ECT process is based on the electromagnet properties of components in the volume measurement. In this thesis, MATLAB is used to generate raw ECT dataset with using an ECT simulator. The variable value of an ECT design parameters affect the sensitivity of raw ECT dataset. In this project, the range of pipe thickness, R2 is uses 1.02 to 1.38 units and the range of electrode angle, θ is 5' to 24'. The mean of absolute error with comparison between oil height target and oil height ANN measurement is plot in two graphs, mean absolute error versus parameter R2 and mean absolute error versus parameter θ. The graphs show the changes in oil height estimation that occur when the ECT system parameters are changed.
format Monograph
id my.usm.eprints.57793
institution Universiti Sains Malaysia
language en
publishDate 2005
publisher Universiti Sains Malaysia
record_format eprints
spelling my.usm.eprints.57793 http://eprints.usm.my/57793/ Optimum Electrical Capacitance Tomography Sensor For Oil-Height Determination Hamzah, Muhamed Sufian T Technology TK Electrical Engineering. Electronics. Nuclear Engineering There are two types of tomography systems, medical tomography and process tomography. ECT is one of the branches of process tomography. ECT or Electrical Capacitance Tomography is one of the techniques to measure the internal spatial distribution of materials. This new and very detailed knowledge allows improved design of process equipment. ECT process is based on the electromagnet properties of components in the volume measurement. In this thesis, MATLAB is used to generate raw ECT dataset with using an ECT simulator. The variable value of an ECT design parameters affect the sensitivity of raw ECT dataset. In this project, the range of pipe thickness, R2 is uses 1.02 to 1.38 units and the range of electrode angle, θ is 5' to 24'. The mean of absolute error with comparison between oil height target and oil height ANN measurement is plot in two graphs, mean absolute error versus parameter R2 and mean absolute error versus parameter θ. The graphs show the changes in oil height estimation that occur when the ECT system parameters are changed. Universiti Sains Malaysia 2005-03-01 Monograph NonPeerReviewed application/pdf en http://eprints.usm.my/57793/1/Optimum%20Electrical%20Capacitance%20Tomography%20Sensor%20For%20Oil-Height%20Determination_Muhamed%20Sufian%20Hamzah.pdf Hamzah, Muhamed Sufian (2005) Optimum Electrical Capacitance Tomography Sensor For Oil-Height Determination. Project Report. Universiti Sains Malaysia, Pusat Pengajian Kejuruteraan Elektrik dan Elektronik. (Submitted)
spellingShingle T Technology
TK Electrical Engineering. Electronics. Nuclear Engineering
Hamzah, Muhamed Sufian
Optimum Electrical Capacitance Tomography Sensor For Oil-Height Determination
title Optimum Electrical Capacitance Tomography Sensor For Oil-Height Determination
title_full Optimum Electrical Capacitance Tomography Sensor For Oil-Height Determination
title_fullStr Optimum Electrical Capacitance Tomography Sensor For Oil-Height Determination
title_full_unstemmed Optimum Electrical Capacitance Tomography Sensor For Oil-Height Determination
title_short Optimum Electrical Capacitance Tomography Sensor For Oil-Height Determination
title_sort optimum electrical capacitance tomography sensor for oil-height determination
topic T Technology
TK Electrical Engineering. Electronics. Nuclear Engineering
url http://eprints.usm.my/57793/1/Optimum%20Electrical%20Capacitance%20Tomography%20Sensor%20For%20Oil-Height%20Determination_Muhamed%20Sufian%20Hamzah.pdf
http://eprints.usm.my/57793/
url_provider http://eprints.usm.my/