Close accord on partial discharge diagnosis during voltage harmonics in electric motors fed by variable frequency drives

Partial discharge (PD) diagnostics test is a reliable solution for estimating insulation health conditions in power system components. During laboratory PD diagnostics, the effect of harmonic components in the voltage waveform generated by variable frequency drives (VFD) fed electric motors (EMs) is...

Full description

Saved in:
Bibliographic Details
Main Authors: Hassan W., Akmal M., Hussain G.A., Raza A., Shafiq M.
Other Authors: 56038670200
Format: Article
Published: John Wiley and Sons Inc 2025
Subjects:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1833350945349566464
author Hassan W.
Akmal M.
Hussain G.A.
Raza A.
Shafiq M.
author2 56038670200
author_facet 56038670200
Hassan W.
Akmal M.
Hussain G.A.
Raza A.
Shafiq M.
author_sort Hassan W.
building UNITEN Library
collection Institutional Repository
content_provider Universiti Tenaga Nasional
content_source UNITEN Institutional Repository
continent Asia
country Malaysia
description Partial discharge (PD) diagnostics test is a reliable solution for estimating insulation health conditions in power system components. During laboratory PD diagnostics, the effect of harmonic components in the voltage waveform generated by variable frequency drives (VFD) fed electric motors (EMs) is often overlooked. As VFD-fed EMs operate at low speeds, the harmonic concentration in the voltage increases. It has been found that PD activity in VFD-fed EM is significantly affected by the addition of harmonic components in the voltage, thus making it necessary to consider their impact when performing true PD diagnostics. This paper investigates the influence of voltage harmonic distortion produced in VFD-fed EM on PD severity and the subsequent insulation degradation. Eight VFD-fed EM are used to study the PD behaviour under different levels of harmonic pollution. The PD characteristics, such as inception voltage, pulse repetition rate, accumulated apparent charge, average discharge current, discharge power, and quadratic rate, are determined. Using probability distribution functions, PD activity and severity at various voltage harmonic levels are estimated. The proposed technique can be used to plan the maintenance activities that ensure the reliability for industrial applications dealing with the voltage harmonic distortion. ? 2023 The Authors. IET Generation, Transmission & Distribution published by John Wiley & Sons Ltd on behalf of The Institution of Engineering and Technology.
format Article
id my.uniten.dspace-36783
institution Universiti Tenaga Nasional
publishDate 2025
publisher John Wiley and Sons Inc
record_format dspace
spelling my.uniten.dspace-367832025-03-03T15:44:39Z Close accord on partial discharge diagnosis during voltage harmonics in electric motors fed by variable frequency drives Hassan W. Akmal M. Hussain G.A. Raza A. Shafiq M. 56038670200 56830270900 57203105565 58787225100 56984295900 AC motors Distribution functions Electric drives Electric power distribution Electric power transmission Harmonic analysis Harmonic distortion Partial discharges Pulse repetition rate Diagnostic tests Harmonics component Harmonics distortion Partial discharge activity Partial discharge diagnosis Partial discharge measurements Variable frequency drives Variable-speed drives Voltage harmonic distortion Voltage harmonics Variable speed drives Partial discharge (PD) diagnostics test is a reliable solution for estimating insulation health conditions in power system components. During laboratory PD diagnostics, the effect of harmonic components in the voltage waveform generated by variable frequency drives (VFD) fed electric motors (EMs) is often overlooked. As VFD-fed EMs operate at low speeds, the harmonic concentration in the voltage increases. It has been found that PD activity in VFD-fed EM is significantly affected by the addition of harmonic components in the voltage, thus making it necessary to consider their impact when performing true PD diagnostics. This paper investigates the influence of voltage harmonic distortion produced in VFD-fed EM on PD severity and the subsequent insulation degradation. Eight VFD-fed EM are used to study the PD behaviour under different levels of harmonic pollution. The PD characteristics, such as inception voltage, pulse repetition rate, accumulated apparent charge, average discharge current, discharge power, and quadratic rate, are determined. Using probability distribution functions, PD activity and severity at various voltage harmonic levels are estimated. The proposed technique can be used to plan the maintenance activities that ensure the reliability for industrial applications dealing with the voltage harmonic distortion. ? 2023 The Authors. IET Generation, Transmission & Distribution published by John Wiley & Sons Ltd on behalf of The Institution of Engineering and Technology. Final 2025-03-03T07:44:38Z 2025-03-03T07:44:38Z 2024 Article 10.1049/gtd2.13089 2-s2.0-85180190436 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85180190436&doi=10.1049%2fgtd2.13089&partnerID=40&md5=a218dfb79fa2745481a142f4df8abb27 https://irepository.uniten.edu.my/handle/123456789/36783 18 3 506 516 All Open Access; Gold Open Access; Green Open Access John Wiley and Sons Inc Scopus
spellingShingle AC motors
Distribution functions
Electric drives
Electric power distribution
Electric power transmission
Harmonic analysis
Harmonic distortion
Partial discharges
Pulse repetition rate
Diagnostic tests
Harmonics component
Harmonics distortion
Partial discharge activity
Partial discharge diagnosis
Partial discharge measurements
Variable frequency drives
Variable-speed drives
Voltage harmonic distortion
Voltage harmonics
Variable speed drives
Hassan W.
Akmal M.
Hussain G.A.
Raza A.
Shafiq M.
Close accord on partial discharge diagnosis during voltage harmonics in electric motors fed by variable frequency drives
title Close accord on partial discharge diagnosis during voltage harmonics in electric motors fed by variable frequency drives
title_full Close accord on partial discharge diagnosis during voltage harmonics in electric motors fed by variable frequency drives
title_fullStr Close accord on partial discharge diagnosis during voltage harmonics in electric motors fed by variable frequency drives
title_full_unstemmed Close accord on partial discharge diagnosis during voltage harmonics in electric motors fed by variable frequency drives
title_short Close accord on partial discharge diagnosis during voltage harmonics in electric motors fed by variable frequency drives
title_sort close accord on partial discharge diagnosis during voltage harmonics in electric motors fed by variable frequency drives
topic AC motors
Distribution functions
Electric drives
Electric power distribution
Electric power transmission
Harmonic analysis
Harmonic distortion
Partial discharges
Pulse repetition rate
Diagnostic tests
Harmonics component
Harmonics distortion
Partial discharge activity
Partial discharge diagnosis
Partial discharge measurements
Variable frequency drives
Variable-speed drives
Voltage harmonic distortion
Voltage harmonics
Variable speed drives
url_provider http://dspace.uniten.edu.my/