Heat Rate Deviation Analysis of a Coal-Fired Power Plant (CFPP) with the Influence of Applicable Coal Prices (ACP)

The assessment of a Coal-Fired Power Plant (CFPP) performance is an intricate process that involves the determination of Heat Rate (HR) deviations of current operational parameters from baseline or target values. This study focuses on HR deviations of a CFPP based on the Applicable Coal Price (ACP),...

Full description

Saved in:
Bibliographic Details
Main Authors: Singh M.S.J., Jalil N.A.A., Rahim S.A., Zulkefli Z.A., Hasini H.
Other Authors: 57712384500
Format: Article
Published: Universiti Putra Malaysia Press 2024
Subjects:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1833410763073519616
author Singh M.S.J.
Jalil N.A.A.
Rahim S.A.
Zulkefli Z.A.
Hasini H.
author2 57712384500
author_facet 57712384500
Singh M.S.J.
Jalil N.A.A.
Rahim S.A.
Zulkefli Z.A.
Hasini H.
author_sort Singh M.S.J.
building UNITEN Library
collection Institutional Repository
content_provider Universiti Tenaga Nasional
content_source UNITEN Institutional Repository
continent Asia
country Malaysia
description The assessment of a Coal-Fired Power Plant (CFPP) performance is an intricate process that involves the determination of Heat Rate (HR) deviations of current operational parameters from baseline or target values. This study focuses on HR deviations of a CFPP based on the Applicable Coal Price (ACP), and the influence of the ACP price on daily losses or gains are thoroughly analyzed for key performance parameters for three fixed ACP of RM12, 18, and 24 per GJ. This paper mainly investigates key parameters and related equipment that significantly affect the HR of the CFPP and ranks the parameters affecting HR from most significant to least significant. The baseline or target values are obtained from the plant commissioning manuals and the Performance Guarantee Test (PGT). Actual real-life operational data from a 700MWn CFPP is utilized to improve the accuracy and confidence levels of the results obtained. It was found that at the nominal operating baseload, the most significant negative HR deviation is for the Rotary Air Heater (RAH) gas exit temperature with a negative HR deviation of-137.9 kJ/kWh leading to an annual loss of RM17.6 million at ACP of RM24/GJ while the superheater and reheater spray flows are contributing least to the HR deviation. This analysis highlighting the impact of key parameters affecting the performance enables plant operations and maintenance teams to focus on such parameters to mitigate losses. � Universiti Putra Malaysia Press.
format Article
id my.uniten.dspace-34277
institution Universiti Tenaga Nasional
publishDate 2024
publisher Universiti Putra Malaysia Press
record_format dspace
spelling my.uniten.dspace-342772024-10-14T11:18:47Z Heat Rate Deviation Analysis of a Coal-Fired Power Plant (CFPP) with the Influence of Applicable Coal Prices (ACP) Singh M.S.J. Jalil N.A.A. Rahim S.A. Zulkefli Z.A. Hasini H. 57712384500 36942027300 37114756400 35340175200 6507435998 Applicable coal price coal-fired power plant performance heat rate heat rate deviation analysis The assessment of a Coal-Fired Power Plant (CFPP) performance is an intricate process that involves the determination of Heat Rate (HR) deviations of current operational parameters from baseline or target values. This study focuses on HR deviations of a CFPP based on the Applicable Coal Price (ACP), and the influence of the ACP price on daily losses or gains are thoroughly analyzed for key performance parameters for three fixed ACP of RM12, 18, and 24 per GJ. This paper mainly investigates key parameters and related equipment that significantly affect the HR of the CFPP and ranks the parameters affecting HR from most significant to least significant. The baseline or target values are obtained from the plant commissioning manuals and the Performance Guarantee Test (PGT). Actual real-life operational data from a 700MWn CFPP is utilized to improve the accuracy and confidence levels of the results obtained. It was found that at the nominal operating baseload, the most significant negative HR deviation is for the Rotary Air Heater (RAH) gas exit temperature with a negative HR deviation of-137.9 kJ/kWh leading to an annual loss of RM17.6 million at ACP of RM24/GJ while the superheater and reheater spray flows are contributing least to the HR deviation. This analysis highlighting the impact of key parameters affecting the performance enables plant operations and maintenance teams to focus on such parameters to mitigate losses. � Universiti Putra Malaysia Press. Final 2024-10-14T03:18:47Z 2024-10-14T03:18:47Z 2023 Article 10.47836/pjst.31.3.18 2-s2.0-85154544509 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85154544509&doi=10.47836%2fpjst.31.3.18&partnerID=40&md5=b93ba7656b0967cffb81d6522d94dbc7 https://irepository.uniten.edu.my/handle/123456789/34277 31 3 1453 1474 All Open Access Hybrid Gold Open Access Universiti Putra Malaysia Press Scopus
spellingShingle Applicable coal price
coal-fired power plant performance
heat rate
heat rate deviation analysis
Singh M.S.J.
Jalil N.A.A.
Rahim S.A.
Zulkefli Z.A.
Hasini H.
Heat Rate Deviation Analysis of a Coal-Fired Power Plant (CFPP) with the Influence of Applicable Coal Prices (ACP)
title Heat Rate Deviation Analysis of a Coal-Fired Power Plant (CFPP) with the Influence of Applicable Coal Prices (ACP)
title_full Heat Rate Deviation Analysis of a Coal-Fired Power Plant (CFPP) with the Influence of Applicable Coal Prices (ACP)
title_fullStr Heat Rate Deviation Analysis of a Coal-Fired Power Plant (CFPP) with the Influence of Applicable Coal Prices (ACP)
title_full_unstemmed Heat Rate Deviation Analysis of a Coal-Fired Power Plant (CFPP) with the Influence of Applicable Coal Prices (ACP)
title_short Heat Rate Deviation Analysis of a Coal-Fired Power Plant (CFPP) with the Influence of Applicable Coal Prices (ACP)
title_sort heat rate deviation analysis of a coal-fired power plant (cfpp) with the influence of applicable coal prices (acp)
topic Applicable coal price
coal-fired power plant performance
heat rate
heat rate deviation analysis
url_provider http://dspace.uniten.edu.my/