Simulation of three phase shunt active power filter to mitigate harmonic current using simulink

TK3101 .G36 2016

Saved in:
Bibliographic Details
Main Author: Gan, Chee Kai
Format: text::Final Year Project
Language:en
Published: 2024
Subjects:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1838943264321830912
author Gan, Chee Kai
author_facet Gan, Chee Kai
author_sort Gan, Chee Kai
building UNITEN Library
collection Institutional Repository
content_provider Universiti Tenaga Nasional
content_source UNITEN Institutional Repository
continent Asia
country Malaysia
description TK3101 .G36 2016
format Resource Types::text::Final Year Project
id my.uniten.dspace-33292
institution Universiti Tenaga Nasional
language en
publishDate 2024
record_format dspace
spelling my.uniten.dspace-332922025-07-24T14:33:39Z Simulation of three phase shunt active power filter to mitigate harmonic current using simulink Gan, Chee Kai Harmonic analyzers TK3101 .G36 2016 Harmonic current is one of the main power quality issues happen in the plant industry nowadays. It is being produced by non-linear loads such as variable speed drive," induction motor, thyristor-based inverter etc. These non-linear loads normally employ the usage of power electronics device. This is undesirable as the harmonic current will damage equipment easily thus reducing the lifespan. The most common way to solve this problem is by using passive filter. However, it has undesirable downsides. 7 Therefore, this research focuses on mitigating the harmonic problem by designing a shunt active filter based on PQ Theory introduced by H. Akagi. This theory uses Clarke transformation and inverse of it to calculate the compensation current needed to inject to cancel the harmonic current produced at the load side. The simulation is done using Simulink software. From different cases studied, author can analyse the behaviour of waveforms and study the Total Harmonic Distortion obtained. 2024-08-22T04:25:44Z 2024-08-22T04:25:44Z 2016 Resource Types::text::Final Year Project https://irepository.uniten.edu.my/handle/123456789/33292 en application/pdf
spellingShingle Harmonic analyzers
Gan, Chee Kai
Simulation of three phase shunt active power filter to mitigate harmonic current using simulink
title Simulation of three phase shunt active power filter to mitigate harmonic current using simulink
title_full Simulation of three phase shunt active power filter to mitigate harmonic current using simulink
title_fullStr Simulation of three phase shunt active power filter to mitigate harmonic current using simulink
title_full_unstemmed Simulation of three phase shunt active power filter to mitigate harmonic current using simulink
title_short Simulation of three phase shunt active power filter to mitigate harmonic current using simulink
title_sort simulation of three phase shunt active power filter to mitigate harmonic current using simulink
topic Harmonic analyzers
url_provider http://dspace.uniten.edu.my/