Analysis of time domain reflectometry parameters for XLPE cable diagnostics
TA660.C3 N87 2015
Saved in:
| Main Author: | |
|---|---|
| Format: | text::Final Year Project |
| Language: | en_US |
| Published: |
2024
|
| Subjects: | |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1839753771926683648 |
|---|---|
| author | Nur Arina Awang |
| author_facet | Nur Arina Awang |
| author_sort | Nur Arina Awang |
| building | UNITEN Library |
| collection | Institutional Repository |
| content_provider | Universiti Tenaga Nasional |
| content_source | UNITEN Institutional Repository |
| continent | Asia |
| country | Malaysia |
| description | TA660.C3 N87 2015 |
| format | Resource Types::text::Final Year Project |
| id | my.uniten.dspace-32624 |
| institution | Universiti Tenaga Nasional |
| language | en_US |
| publishDate | 2024 |
| record_format | dspace |
| spelling | my.uniten.dspace-326242025-07-29T12:26:59Z Analysis of time domain reflectometry parameters for XLPE cable diagnostics Nur Arina Awang Cable structures Cables-Standards TA660.C3 N87 2015 This project puts forward a guidance to analyse and set appropriate parameter of Time Domain Reflectometry (TDR) system in order to diagnose the test cable. TDR is equipment that functions to detect fault in cables. Certain parameters likes pulse amplitude and pulse width need to be varied based on the suitability of the cable to be tested. As the test cable, XLPE insulated type is chose due to the well application of it in both power transmission and distribution. Those cable need to be maintained to ensure the well performance in preventing negative impact on customer's side. 2024-06-13T08:41:58Z 2024-06-13T08:41:58Z 2015 Resource Types::text::Final Year Project https://irepository.uniten.edu.my/handle/123456789/32624 en_US application/pdf |
| spellingShingle | Cable structures Cables-Standards Nur Arina Awang Analysis of time domain reflectometry parameters for XLPE cable diagnostics |
| title | Analysis of time domain reflectometry parameters for XLPE cable diagnostics |
| title_full | Analysis of time domain reflectometry parameters for XLPE cable diagnostics |
| title_fullStr | Analysis of time domain reflectometry parameters for XLPE cable diagnostics |
| title_full_unstemmed | Analysis of time domain reflectometry parameters for XLPE cable diagnostics |
| title_short | Analysis of time domain reflectometry parameters for XLPE cable diagnostics |
| title_sort | analysis of time domain reflectometry parameters for xlpe cable diagnostics |
| topic | Cable structures Cables-Standards |
| url_provider | http://dspace.uniten.edu.my/ |
